SMC Corporation of America
Elite Part Number Search
Search Results "RZQA40TN-150-60-M9BZ"

type: 5 to 150) 1 x 10-6 up to atmospheric pressure Operating pressure (Pa)(abs) Conductance (L/s) Note 1) 14 45 80 160 200 5 1.3 x 10-10 {1 x 10-10} at ambient temperature, excluding gas permeation (Standard material: FKM) Internal Leakage (Pam 3/s) 1.3 x 10-11 {1 x 10-11} at ambient temperature, excluding gas permeation (Standard material: FKM) External Operating time (s) 0.1 0.21 0.24

Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit. For a stroke in the standard stroke range, suffix the part number with -XB10.

Product weight [kg] Model Stroke Additional weight Size Motor type 50 100 150 with lock 16 V6 1.85 2.24 0.30 25 V7 3.68 4.28 5.68 0.60 -8- 1.3 Construction LESYH*R / LESYH*L R type as shown L type opposite as shown Cables includid A-A (D type) Component parts No. Description Material Remarks No.

Standard Stroke Maximum stroke available (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit.

The intersection E is the dew point under pressure 0.7 MPa with the ambient temperature of 30C and the relative humidity of 60%. Value for E is at 62C. 5. Trace the intersection E upward, and C leftward to obtain the intersection D. 6. The intersection C is the amount of water included in the compressed air 1 m3 at 0.7 MPa with the pressure dew point of 62C.

Equipment Uo (or Voc) lo (or Isc) Po Co (or Ca) Lo (La) Ui li Pi Ci + Ccable Li + Lcable If the cable capacitance and inductance are unknown, use the following values: Ccable = 60 pF/ft., Lcable = 0.2 H/ft.

CHKGB Bore size Rod end thread type Auto switch Quantity XC63 Stroke Intermediate stroke Applicable tube For 75mm stroke For 100mm stroke Strokes 55, 60, 65, 70 80, 85, 90, 95 Dimensions CHKGB--XC63 B A 55, 60, 65, 70 80, 85, 90, 95 Stroke Bore size (mm) A B A B 32 141 131 40 150 140 175 165 50 156 145 181 170 63 165 152 190 177 80 180 163 205 188 100 207 181 232 206 Note) Dimensions other

Rotations per Second Distance of movement per second Distance of movement per rotation Rotation Speed (rpm) = Speed (mm/s) Lead (mm) }60 (S) = {500 (mm/s) 20 (mm) }60 (s) =1500 (rpm) 46 - 5.6.3 Acceleration/deceleration Time Configuation < Acceleration/deceleration Time Configuration> Acceleration/deceleration time (ms) configuration: The acceleration/deceleration time sets the amount

Q [l/min(ANR)] = x D2 x W x (P2 + 0.101) x 60 x C 6 4 x 10 0. 101 VBAT10, VBAT20, VBAT38 Q [l/min(ANR)] = x 1002 x 200 x (0.8 + 0.101) x 60 x 1 = 841 4 x 106 0. 101 Select booster regulator size from flow characteristics table. Refer to page 14-9-3 for flow characteristics.

Standard Strokes Bore size [mm] Standard stroke [mm] Max. manufacturable stroke 32 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 300 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 300 45 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 300 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 400 56 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 400 63 25, 50, 75, 100, 125, 150

, 175, 200, 250, 300, 350, 400, 450, 500 C95 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 CA1 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 CS1 80 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 100 25, 50, 75, 100, 125, 150, 175, 200

-D IS10L-40-m02-D IS10L-40-m03-D IS10L-40-m04-D IS10L-60-m04-D IS10L-60-m06-D IS10L-60-m10-D Pressure switch with L-shaped piping adapter*5, *6 IS10L-20-m01-D IS10L-20-m02-D IS10L-50-m04-D IS10L-50-m06-D p. 56 IS10E-40-m02-D IS10E-40-m03-D IS10E-40-m04-D IS10E-40-m06-D IS10E-60-m06-D IS10E-60-m10-D IS10E-60-m12-D IS10E-60-m14-D IS10E-20-m01-D IS10E-20-m02-D IS10E-20-m03-D IS10E-30-m02-D IS10E

(g) Stroke (mm) Model 5 10 15 20 25 30 40 50 60 70 80 90 100 33 (38) 36 (46) 40 (50) 43 (53) 46 (56) 50 (60) 57 (67) 64 (74) 71 (81) C(D)UKW6-D 51 (56) 56 (66) 60 (70) 65 (75) 69 (79) 74 (84) 83 (93) 92 (102) 101 (111) C(D)UKW10-D 84 (109) 91 (121) 98 (128) 105 (135) 112 (142) 119 (149) 133 (163) 147 (177) 161 (191) C(D)UKW16-D 150 (185) 163 (203) 177 (217) 191 (231) 205 (245) 219 (259) 247

Seal Coil voltage 1 100 VAC (50/60 Hz) 2 200 VAC (50/60 Hz) 3 110 VAC (50/60 Hz) 4 220 VAC (50/60 Hz) 5 24 VDC 6 12 VDC Series Enter in order starting from the first station on the D side.

[mm] 63 15 105 59 130 101 Size H U UU 50 39 114 150 63 45 136 177 80 55 165 215 100 60 190 250 Size H N U UU 50 30 15 105 125 63 33 17 124 146 80 43 20 153 178 100 44 25 174 204 80 18 130 76 160 119 100 18 150 92 180 133 DThe dimensions of shaft key and four chamfers are the same as the basic type.

(V) 24, 6, 12, 48 15 to +10% of rated voltage 1.8 (With indicator light 2.1) [24 VDC: 75 (With indicator light 87.5)] Body ported Allowable voltage fluctuation (%) Power consumption (W) [Current mA] DC Note) 4.5/50 Hz, 4.2/60 Hz 100 VAC: 45/50 Hz, 42/60 Hz 200 VAC: 22.5/50 Hz, 21/60 Hz Note) Inrush Apparent power (VA) [Current mA] AC Holding 3.5/50 Hz, 3/60 Hz 100 VAC: 35/50 Hz, 30/60 Hz

VN Rated voltage 1 2 3 4 5 6 7 8 9 Solenoid valve option Nil Standard 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz Other (Please contact SMC separately.) LVC Select an option mark in page 17-3-10 by Applicable Fluids Check List for special fluids outside of the standard.

MY Standard Stroke CY (mm) MG Manufacturable stroke range Model Standard strokes CXSJ6 CXSJ10 CXSJ15 CXSJ20, 25, 32 60 to 100 10, 20, 30, 40, 50 CX 80 to 150 10, 20, 30, 40, 50, 75 110 to 150 D10, 20, 30, 40, 50, 75, 100 110 to 200 Strokes beyond the standard stroke range are available as a special order.

22 11 2-M5 x 0.8 50 29 6 12 4.5 25 10 12 45 67.5 9 2-M5 x 0.8 with depth 7.5 25 73 29 87 71 27 13.5 2-M6 x 1.0 60 35 6 12 4.5 30 12 14.5 46 70.5 9 2-M5 x 0.8 with depth 7.5 32 94 37 100.5 92 35 17.5 2-M6 x 1.0 75 45 8 16 4 30 16 18.5 56 80.5 10 Symbol Z Stroke Bore size (mm) 10, 20 30, 40, 50 75 100 15 20 25 32 25 35 45 55 30 40 60 60 30 40 60 60 40 50 70 70 8-28-26 26 Series CXSJ Dual Rod

1 2 3 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Note) Electrical entry: D or DZ only 4 4 5 6 5 6 Manual override 7 7 Non-locking push type Non-locking push type A (projecting) Nil Semi-standard For other rated voltages, please consult with SMC.