(Rotation range of single flat (key) when mounting 2 stopper blocks on the other sides groove is the opposite side from
JIS symbol Minimum Operating Pressure Unit: MPa Bore size (mm) Minimum operating pressure 20 25 32 40 50 63 80 100 0.02 0.01 Standard Stroke Table Replacement Parts: Seal Kits Bore size (mm) Bore size (mm) 20 25, 32, 40, 50, 63, 80, 100 Standard stroke (mm) Note 1) Contents Kit No. 25, 50, 75, 100, 125, 150, 200 25, 50, 75, 100, 125, 150, 200, 250, 300 20 25 32 40 50 63 80 100 CG1Y20-PS CG1Y25
Deflection + L F F (Dimension when extended) + M Built-in coil scraper and Lube-retainer MAllowable lateral load graph MSelectable proximity switches CKZP57L TURCK P&F 400 Allowable lateral load [N] 350 300 250 200 MAdjustable connector angle 150 100 CKZP57L: 45, 90 CKZP71: 0, 45, 90 50 0 0 50 100 150 200 250 Offset distance L [mm] CKZP71 0 50 100 150 200 250 300 350 400 450 500
0.5MPa 0.5MPa Gripping force N Gripping force N 0.4MPa 0.4MPa 150 150 F 0.3MPa 0.3MPa 100 100 0.2MPa 0.2MPa 50 50 0.1MPa 0.1MPa 0 0 10 10 20 20 30 30 40 40 50 50 Gripping point L mm Gripping point L mm MHS2-50D MHS2-50D F 400 400 Internal gripping Pressure 0.6MPa Pressure 0.6MPa 300 300 Gripping force N 0.5MPa 0.5MPa Gripping force N 0.4MPa 0.4MPa 200 200 0.3MPa 0.3MPa 1N: Approx. 0.102kgf
C4 C6 C4 C6 Stations L1 L2 L3 L4 3 4 5 6 7 8 9 10 2 123 135.5 125 102 16.5 148 148 160.5 150 173 185.5 175 198 210.5 200 112.5 91.5 15.5 137.5 137.5 123 12.5 162.5 144 14.5 187.5 165 16.5 133.5 13.5 154.5 15.5 175.5 17.5 112.5 17.5 Stations SS5Y3-45GUBC4 C6 2 3 4 5 6 7 8 9 10 Stations L1 L2 L3 L4 135.5 125 108 13.5 148 160.5 150 129 15.5 173 185.5 175 150 17.5 185.5 175 198 210.5 200 223
F F MHL2-10D Z-X85 MHL2-16D Z-X85 1 2 1 2 MHL2-10DZ-X85 MHL2-16DZ-X85 25 25 70 60 70 60 20 20 Pressure 0.6 MPa Gripping force [N] Gripping force [N] Gripping force [N] Gripping force [N] Pressure 0.6 MPa Pressure 0.6 MPa 50 50 Pressure 0.6 MPa 0.5 MPa 0.5 MPa 15 15 40 40 0.5 MPa 0.5 MPa 0.4 MPa 0.4 MPa 30 30 10 10 0.4 MPa 0.4 MPa 0.30 MPa 0.3 MPa 20 20 5 5 10 10 0 0 10 20 30 40 50 60 70 0
(not including sensor accuracy), Response speed: 150 ms or less Resistance Weight Analog output 0.6% F.S. or less 1.0% F.S. or less 1.5% F.S. or less Accuracy (to display value) (25C) Output current: 4 to 20 mA (within rated pressure range) Current output Note 2) Maximum load impedance: 300 (at 12 VDC), 600 (at 24 VDC), Minimum load impedance: 50 Linearity: 0.2% F.S.
Switch (When equipped with switch) Internal Pilot Manifold L Dimension n: Stations External Pilot Manifold L Dimension n: Stations L n 4 160.5 150 129 16 L n 4 173 162.5 139.5 17 2 135.5 125 108 14 3 148 137.5 118.5 15 5 173 162.5 139.5 17 6 185.5 175 150 18 7 185.5 175 160.5 12.5 8 198 187.5 171 13.5 9 210.5 200 181.5 14.5 10 223 212.5 192 15.5 2 148 137.5 118.5 15 3 160.5 150 129 16 5 185.5
Application Weight (g) Model Actuator Polyacetal roller 110 140 150 150 160 220 210 220 210 220 200 VM430-01-00 VM430-01-01 VM430-01-01S VM430-01-02 VM430-01-02S Basic VM-08A VM-07AS VM-07A VM-06AS VM-06A VM-05A VM-02AS VM-02A VM-01AS VM-01A Mechanical operation Manual operation Roller lever Hard steel roller Polyacetal roller Hard steel roller One way roller lever Straight plunger VM430
0.4MPa 10 0.4MPa 0.3MPa SUP = 0.5MPa 0.3MPa 0.2 100 0.2MPa 0.3MPa 0.2MPa 5 50 0.1 0.2MPa 00 50 100 150 00 5 10 00 5 10 Air consumption (l/min [ANR]) Flow rate (l/min) Operating cycle (Hz) PAP3313-T13: Flow rate characteristics (2.5Hz)* PAP3313-T13: Flow rate characteristics (5Hz)* PAP3310-T13: Flow rate characteristics 0.4 0.5 0.5 Discharge pressure (MPa) Discharge pressure (MPa) Discharge
121 90 188 141 294 215 482 362 754 565 0.5 25 19 57 42 101 75 157 118 245 179 402 302 628 471 8 5, 10, 15, 20, 25, 30 OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN 50 37 113 84 201 150 314 235 490 358 804 603 1,256 942 8 12, 16 25, 50, 75, 100 25, 50, 75, 100, 125, 150, 175, 200 12 20, 25, 32, 40 16 Strokes other than the above are produced upon receipt of order. 20 Stud Bolt Part Numbers
SUP = 0.2 MPa 0.2 0.2 0.2 0.1 0.1 0.1 0 0 0 50 100 150 200 0 Discharge (mL/min) 0 Discharge (mL/min) 200 400 600 800 1000 0 Discharge (mL/min) 200 400 600 800 1000 Air Consumption: Built-in Solenoid Valve/Air Operated Calculation of Air Consumption Air Consumption 45 Find the air consumption for operation with a 5 Hz switching cycle and pilot air pressure of 0.35 MPa from the air consumption
WETTED MATERIALS Polysulfone, Silicone, Buna-N TEMPERATURE RANGE 40 150 F (4 66 C) REPEATABILITY < +/1% F.S.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 2 to 50 Indoor Three phases 200 VAC (50/60 Hz) Three phases 200 VAC (50/60 Hz) Single phase 100 VAC (50/60 Hz) Single phase 200 VAC (50/60 Hz) Single phase 100 VAC (50/60 Hz) Three phases 200 VAC (50/60 Hz) Power source 90 130 0.4 0.45 1.44 1.4 50 60
No.CE*-OMP0002-A 3 CEU1 SMC FG 0~50 35~85%RH 3 CEU1CE10.1mm 3 CE1-R** CE1** 3 CEU1** FG 3 DIN 3 2m/s 3 (100ms) 2 2 2 2-1 1 1 1 CEU1 4 2 2 2 2-2 2 2 2 3 3 3 3-1 1 1 1 : : 1 1 (mm) (mm) 25 25 25 25 50 50 50 50 75 75 75 75 100 100 100 100 125 125 125 125 150 150 150 150 175 175 175 175 200 200 200 200 250 250 250 250 300 300 300 300 400 400 400 400 500 500 500 500 12 12 12 12
Load mass Allowable moment MY1H/m MY1H/M MY1H/M MY1H/M 2 1 3 40 50 50 40 50 40 50 4 40 5 30 30 30 30 20 20 20 20 MY1H40 MY1H32 MY1H40 MY1H32 10 10 10 MY1H40 MY1H40 MY1H40 MY1H40 MY1H32 MY1H40 MY1H32 MY1H32 MY1H32 MY1H32 5 4 MY1H25 MY1H25 10 MY1H40 MY1H40 Load mass kg Moment Nm Moment Nm Moment Nm 5 4 5 4 MY1H32 MY1H32 MY1H25 MY1H25 MY1H25 3 MY1H25 MY1H25 MY1H20 MY1H20 3 3 2 MY1H25 MY1H25
Model determination 61 Series REBR Model Selection 2 Design Parameters 1 Selection Method REBR25 REBR32 REBR15 500 400 300 200 300 200 Allowable driving force Fn (N) Load weight W (kg) Allowable driving force Fn (N) Allowable driving force Fn (N) 50 100 100 40 30 40 50 20 30 40 50 30 20 20 Usable range 10 10 10 Usable
150 117000 yen reduction Current model IR1000 Series IR2000 Series 100 100 IR1000-A Series IR2000-A Series IR3000-A Series 50 50 0 0 0 10 20 30 40 50 0 10 20 30 40 50 Units used Units used Released into atmosphere IR Special bleeding structure No fixed throttle in the new design.
Relationship of liquid entry and sliding distance Amount of liquid entry (g) X 15 10 Standard cylinder Stainless steel cylinder 5 0 50 100 150 200 Sliding distance (km) 250 300 Conditions Working fluid ...Air Pressure .. 0.5MPa Liquid ...
E2 A10 10 96.5 62.5 23 20 134.5 72.5 51 30 144.5 82.5 40 180.5 92.5 77 50 190.5 102.5 N S U F GN GS 20 51.5 33.5 Construction p. 118 J K ZP Y B Buffer Assembly p. 126 10 97 63 23 20 135 73 51 30 145 83 40 181 93 77 50 191 103 25 3.5 6 M10 x 1 14 3 52 34 10 102 68 23 20 140 78 51 30 150 88 40 186 98 77 50 196 108 32 57 39 10 142 74 20 139 84 30 149 94 50 194 114 75 50 40 62 44 N6 U6 A14 6