Terminal no.12 Switch Terminal no. 12 11 Recommended accessory cable dia. is 0.14 to 1.5mm2 9 10 Terminal no.1 Fig. 3-8 Wiring of contact for remote signal inputsExample 3.3 Installation HRS Series 3-12 HRX-OM-R005 Chapter 3 Transport and Setting Up 3. Plug the prepared connector in to the contact input/output connector that is on the back of the thermo-chiller.
Stroke (mm) Refer to the standard stroke table on Page 12.
P, R port thread type Stations SV 04 4 stations Applicable blanking plate assembly SYJ3000-21-3A (With dust cap) Nil Rc : : 00F G SZ 12 12 stations P port 1/8 1/8 00N NPT R port 00T NPTF SY Applicable solenoid valve Refer to page 1-5-15. Type 32P How to Order SS5YJ332P 07 C4 SYJ A, B port M5 x 0.8, C4 Applicable connector assembly Refer to page 1-5-15.
Centigrade(oC) Fahrenheit(oF) 5.13 12 Changing pressure unit Pressure unit can be changed.
) 10 m or less CN3 10 m or less 24 V DC (Note 10) 3 DOCOM (Note 15) Main circuit power supply CN3 (Note 12) (Note 2) (Note 17) Electromagnetic brake interlock 13 MBR (Note 3, 4) Forced stop 2 RA1 20 EM2 (Note 13) 9 INP In-position RA2 FLS DI1 2 15 ALM Malfunction (Note 11) (Note 14) RLS DI2 12 RA3 DOG DI3 19 5 DICOM Encoder A-phase pulse (differential line driver) 6 LA (Note 10) 24 V DC 16
48.4 43.6 42 1/4 19 16.6 13.3 39 AS32l1F-U03-08A 8 13.2 22.7 33 14.2 AS32l1F-U03-10A 10 15.9 26.7 37 28 15.6 40 AS32l1F-U03-12A 12 18.5 29.7 40 26.8 17 42 AS42l1F-U04-10A 10 1/2 24 15.9 18.8 27.4 40.3 36.2 50.8 49.2 42.2 40.6 15.6 52 AS42l1F-U04-12A 12 18.5 30.8 43.7 35.1 17 54 AS42l1F-U04-16A 16 23.8 34.8 47.7 32.7 20.6 58 10.4 21.8 32.1 28.7 42.3 40.7 35.9 34.3 3/8 19 16.6 Note 1) Reference
Refer to p.4.1-12, 4.1-13 for specifications and model.
10 20 12 10 20 20 20 40 LJ1H10 LJ1H20 LJ1H30 LJ1H10 LJ1H20 LJ1H30 LJ1H10 LJ1H20 LJ1H30 LJ1H10 LJ1H20 LJ1H30 2 Horizontal 8 25 25 18 Standard motor 8 12 8 12 24 5 10 5 10 Vertical 32 10 12 10 20 10 12 10 20 40 High rigidity direct acting guide LJ1H 20 20 40 44 Horizontal 50 25 25 60 Non-standard motor 8 12 8 12 66 5 10 5 10 Vertical 74 10 10 82 Options Page 100 Made to Order 101 Clean
D1 D2 L A M M5, M6 Nylon Urethane M5 0.8 M6 1.0 KXH04-M5 KXH04-M6 KXH04-01S KXH06-M5 KXH06-M6 KXH06-01S KXH06-02S KXH08-01S KXH08-02S KXH08-03S KXH10-02S KXH10-03S KXH10-04S KXH12-03S KXH12-04S 38.5 11 13 39 35 8 10.4 2.5 4.0 4.0 16 4 1 8 M5 0.8 M6 1.0 40 39.5 40 42 45 46 49 50 58 59 62 60 63 16 36 12 2.5 3 4.0 4.0 5.6 5.6 15 8 36 6 12.8 15 17 1 8 1 4 1 8 38 39 42 43 44 20 26 28 34 42 68
Valve model Port size VCW2 VCW20-12-01 1/8, 1/4 34 40 25 30 12.8 12.8 5 4.5 6 13 VCW30-12-02 1/4, 3/8 42 52 30 40 19 19 6 5.5 7 19 VCW3 VCW30-12-04 1/2 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-02 1/4, 3/8 42 52 30 40 23 23 6 5.5 7 19 VCW30-12-04 VCW4 1/2 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-06 3/4 56 65 44 53 28.2 28.2 6 5.5 7 26 Bracket material: Stainless steel 3 Series VCW Dimensions (N.C
D2 L A M D1 Nylon Urethane M5 X 0.8 M6 X 1.0 38.5 KXH04-M5 KXH04-M6 KXH04-01S KXH06-M5 KXH06-M6 KXH06-01S KXH06-02S KXH08-01S KXH08-02S KXH08-03S KXH10-02S KXH10-03S KXH10-04S KXH12-03S KXH12-04S 11 13 39 35 8 16 10.4 2.5 4.0 4.0 4 40 39.5 40 42 45 46 49 50 58 59 62 60 63 16 36 12 1 8 M5 X 0.8 M6 X 1.0 2.5 3 4.0 4.0 5.6 5.6 15 8 36 6 17 15 12.8 38 39 42 43 44 1 8 1 4 1 8 20 26 28 34 42 68
DIN rail center 70 (94.4) 100 70 (94.4) 100 90 10 SUP 40 (4.5) 30 Adjusting knob Electrical entry Applicable O.D. 6.5 to 8.5 12 Electrical entry Applicable O.D. 6.5 to 8.5 Bracket Gauge 35 42 8-4.5 Gauge 34 42 4-4.5 42 9-M3 OUT1 OUT2 OUT3 Bracket OUT5 OUT4 EXH port EXH port Station 1 n 69.3(MAX74.4) 69.3(MAX.74.4) 60 OUT 60 19.5 2.1 OUT OUT OUT OUT OUT OUT GND OUT6 19.5 2.1 VCC Detection
Valve model Port size VCS21 VCW20-12-01A 1/8, 1/4 34 40 25 30 12.8 12.8 5 4.5 6 13 VCW30-12-02A 1/4, 3/8 42 52 30 40 19 19 6 5.5 7 19 VCS31 VCW30-12-04A Note 1) 1/2 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-02A 1/4, 3/8 42 52 30 40 23 23 6 5.5 7 19 VCW30-12-04A Note 1) 1/2 VCS41 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-06A 3/4 56 65 44 53 28.2 28.2 6 5.5 7 26 2 mounting screws (for mounting bracket
6 17 1.6 48.2 34 54 44 24 2-Piping port size 4-4.5 40 50 (43.5) 42 2 1 4 3 4 Connector pin numbers 43 2-3.4 Pin name Pin No.
(-F)(-P) VFA1220-01(-F)(-P) (16.6) (16.6) (Distance between ports) (Distance between ports) 38 1/8 [4 (A), 2 (B) port] 12 11.5 1/8 [4 (A), 2 (B) port] (4) 26.4 5 5 B 2 B 2 26.4 12 12 1/8 (Pilot port: Upward) 1/8 (Pilot port: Upward) 4 A 4 A 5 (1.6) 11.5 45.5 (6) 40.5 55.5 1502 VFA1000/3000/5000 Series 5 Port Air Operated Valve Body Ported/Single Unit Dimensions: VFA3000 Series/Body Ported
, 16 n = 4, 8, 12, 16 n = 4, 8, 12, 16 n = 4, 8, 12, 16 n = 4, 8, 12, 16 n = 4, 8, 12, 16 15 20 60 70 85 110 115 120 2 20 + 55 (n 2)/2 25 + 55 (n 2)/2 65 + 55 (n 4)/2 70 + 55 (n 4)/2 85 + 55 (n 4)/2 110 + 55 (n 4)/2 115 + 55 (n 4)/2 120 + 55 (n 4)/2 A59W n n = 2, 4, 6, 8 n = 2, 4, 6, 8 n = 4, 8, 12, 16 n = 4, 8, 12, 16 n = 4, 8, 12, 16 n = 4, 8, 12, 16 n = 4, 8, 12, 16 n = 4, 8, 12
Valve model Port size VCW2 VCW20-12-01 1/8, 1/4 34 40 25 30 12.8 12.8 5 4.5 6 13 VCW30-12-02 1/4, 3/8 42 52 30 40 19 19 6 5.5 7 19 VCW3 VCW30-12-04 1/2 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-02 1/4, 3/8 42 52 30 40 23 23 6 5.5 7 19 VCW30-12-04 VCW4 1/2 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-06 3/4 56 65 44 53 28.2 28.2 6 5.5 7 26 Bracket material: Stainless steel 3 Series VCW Dimensions (
43 22 50 37 47 33 20 40 110 15 25 60 20 3 3.5 M5 x 0.8 10 5 16 49 24 57 42 51 37 20 22 42 110 15 16 26 60 24 3 3.5 M5 x 0.8 10 5 20 60 28.5 71 49 66 44 24 44 120 30 40 78 28 3 3.5 M6 x 1 12 18 25 73 34 86 60 78 50 24 44 12 29 39 77 34 4 4.5 M6 x 1 12 17 [mm] MGPKL: A, DB, and E Dimensions Bore size [mm] A DB E 30 st or less Over 30 st 100 st or less Over 100 st 30 st or less Over 30 st 100
. 12-10-13 13 Series MHY2 Dimensions MHY2-25D 2-M6 x 1 thread depth 10 (Mounting hole) Pin hole positioning 16 5 23 50 4H9 + 0.030 depth4 0 4-M5 x 0.8 (Thread for mounting attachment) 10 4-M6 x 1 thread depth 12 12 0.005 0.025 (Mounting hole) 6 12 26.6 2-M6 x 1 thread depth 12 22.5 (Mounting thread) (Mounting hole) (Limted area for mounting attachment) 46 58 45 45 42 26H9 + 0.052 depth1.5
Refer to pages 12-10-4 to 12-10-5 for the details on effective holding force and allowable overhanging distance. Misc. D20Precautions Be sure to read before handling. Refer to pages 12-15-3 to 12-15-4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, and refer to pages 12-1-4 to 12-1-6 for Precautions on every series.