B C d H MQ10-M MQ16-M MQ20-M MQ25-M MQ28-M NTJ-015A NT-015A NT-02 NT-03 NT-04 10 8 9.2 6 15.5 5 10 9.2 M5 x 0.8 4 20.5 8 16 8 9.2 8 16.5 6 16 11.5 M6 x 1.0 5 22.5 10 20 8 9.2 10 18.5 6 20 15 M8 x 1.25 5 24.5 13 25 10 11.5 12 22.5 11 25 19.6 M10 x 1.25 6 33.5 17 28 14 16 16 28.5 12 28 25.4 M14 x 1.5 8 40.5 22 Applicable bore (mm) Part no.
(For details, refer to "Specific Product Precautions 1" on Page 11.)
How to Order B LG1 02 1 Cable length 02 03 04 05 2m 3m 4m 5m Nonstandard Motor Cables Cables for connecting nonstandard motors and drivers. Cable lengths other than those shown below should be arranged by the customer.
71 68 104 1/2 22 45 90 41 11 17 36 22.5 23 M5 8 26 84 48 74.5 103 74.5 70 107 1/4, 3/8 VCS41 30 50 94 41 13.5 17 36 25 23 M5 8 26 88 48 78.5 103 78.5 70 111.5 1/2 35 60 102 41 17.5 17 36 30 28.2 M5 8 26 96 48 86.5 103 86.5 70 119 3/4 4 Direct Operated 2 Port for Steam Series VCS How to Order Manifolds How to Order Manifold Assemblies (Example) D VV2C S 2 02 01 Enter the valve and option
OUT port size Material D side U side 1 2 3 4 5 n Symbol 01 02 Port size 1/8 (6A) 1/4 (8A) Stations Body material C37 Symbol Nil H Seal material FKM FKM 02 : 10 2 stations : 10 stations Stainless steel All IN ports are 3/8. Refer to the "L" dimensions on page 6 regarding the maximum number of stations.
How to Order Integrated Display Type M PF2A7 10 01 27 Flow rate range 1 to 10 l/min 5 to 50 l/min 10 to 100 l/min 20 to 200 l/min 50 to 500 l/min 10 50 11 21 51 Thread type Unit specification Nil M With unit switching function Fixed SI unit Note) Nil N F Lead wire (Refer to page 35.)
(max. 20 stations) 3 SX3000 5 SX5000 Connector mounting position Symbol Mounting position U U side D D side Valve stations A, B port size Note Symbol 02 Stations SX3000 SX5000 2 stations Port size 4 One-touch fitting 6 One-touch fitting Mixed Symbol Port size 4 One-touch fitting 6 One-touch fitting 8 One-touch fitting Mixed Symbol C4 C6 M Double wiring specification C4 C6 C8 M 08 02 8 stations
AS120-M5 M5 U10/32 01 02 03 04 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 AS120-U10/32 AS220-01 AS220-02 AS320-03 AS420-04 646 B AS Series Speed Controller: Standard Type Elbow Type (Metal Body) Note) The flow rate characteristics are representative values.
For 3 stations For remote I/O A1W DeviceNet PROFIBUS-DP CC-Link 16 For 16 stations A2W 0 Without SI unit Stations Ports 1, 3, 5 position Symbol 02 Stations 2 stations Note U D B U side (2 to 10 stations) D side (2 to 10 stations) Both sides (2 to 16 stations) Note 1) Double wiring specifications 08 02 8 stations 2 stations Note 2) Supply/Exhaust block assembly specification Specified
SI unit for SV series valves ( EX500-S 01 ) ( EX500-Q 02 ) PWR PWR COM COM 64.4 80.3 64.4 28 66 84.8 79.4 68.5 80.3 series 54.5 60 60 43.2 43 43.2 22.2 22 22.2 13 10.5 28.6 44 0 1 36 10.5 1 0 22 23 The mounting and removing methods of SI unit are as shown below.
Panel adapter B ZS-22-02 Thread type Piping port size Rc NPT G Nil N F 01 02 1/8 1/4 Specifications PFA301-m PFA300-m Model Specifications Note 1) 1 to 10, 5 to 50l/min (0.04 to 0.35, 0.18 to 1.77SCFM) Flow rate range measurement & setting Minimum setting unit 1% of maximum flow rate range Model PFA510-m PFA550-m Real-time flow rate l/min, CFM x 10-2 Display units Measured fluids Dry air,
BA -32 BA -04 BM1 -01 BM1 -02 BM1 -32 BM1 -04 Intermediate strokes and short strokes other than the above are produced upon receipt of order.
Mounting Wiring/Piping Caution Warning 11. Transition wiring of ionizer For transition wiring of ionizers, use a transition wiring cable for connection between ionizers. Use a power supply cable for connection between ionizer and power supply or external equipment. (Transition wiring is not possible with the IZS40.)
BA -32 BA -04 BM1 -01 BM1 -02 BM1 -32 BM1 -04 Intermediate strokes and short strokes other than the above are produced upon receipt of order.
(For details, refer to "Specific Product Precautions 1" on Page 11.)
11 Series ZX Suction Filter Unit: ZX1-F Specifications ZX1-F Vacuum to 0.5 MPa 5 to 50C 30 m PVF 35 g Unit no.
IZN10 IZN10 IZN10 IZN10 01 01 01 01 P P P P 06 06 06 06 Z Z Z Z B1 B1 B1 B1 IZN10 AC 01 02 11 Rc1/8 NPN P PNP 06 6 07 6.351/4) 16 6 ( 17 6.351/4() (3m) Z (10m) N IZN10-NT L DIN IZN10A002 IZN10B1 L B2 B3 DIN 01 06 ES 2 01 ES 17mm 2 2 02 3 3 11 Rc1/8 4 4 /IZS30 /IZS30 /IZS30 /IZS30-M2 M2 M2 M2 06 6: 07 6.351/4: 16 6 :( 17 6.35(1/4):() IZN10-CP(3m) IZN10-CPZ(10m) IZN10A003 NPN
Inch size Millimeter size Port size 5/32 04 03 4 M5 M5 x 0.8 Thread type 1/4 06 07 6 U10/32 10-32UNF 5/16 08 09 8 Metric system thread (M5) 01 1/8 3/8 10 11 10 Nil Unified thread (10-32UNF) 02 1/4 1/2 12 13 12 Rc(PT) 03 3/8 N NPT 04 1/2 Check valve free flow direction Applicable Tube O.D.
Wiring 1) Passing through the cable (7), cable gland (4), plain washer (5), rubber seal (6) in this order, and then insert into the housing (2). 2) From the terminal block (3), loosen the screw (11), then pass the lead wire (10) through, then again tighten the screw (11). Note 1) Tighten within the tightening torque of 0.5 Nm 15%.
2l 2.60 (66) s T o 6.61 (168) 1.38 {3s) 3.98 ( 1 0 1 ) 3.35 (85) 2.52 (s) 0 7 9 (20) (40) 0.39 ( 1 0 ) 0.67 ( 1 7 ) 0 2 8 t7l M l a x 1 5 1.22 ( 3 i ) 3.86 (98) 3.39 (86) 0.45 11 5) 0.59 (15) 1105) 2.32 (59) 5 . 1 2 1130) 2.24 (56) 6.73 (171) 2.O5 (52) 11.2) 2.60 (66) 7.05 (179) 5.12 l130) 2.99 (76) 6.30 tr60) 2.80 l71l 4.07 (205) 2.56 (65) 0.49 12 s) 3.15 (80) 8.43 (214) 1.57 (40) 4.69