Lead Wire Clamp/Lead Wire Cap (Option) CNS Series Lead wire clamp LC-01 Lead wire cap LP-01 ML1C CLS Lead Wire Clamp/Lead Wire Cap (Option) (mm) CLQ 25 32 40 Mounting position Series Series Lead wire clamp Lead wire cap A 124.8 148.8 173.8 LP-01 ML1C LC-01 ML1C MLGP B 113.2 137.2 162.2 25 32 40 Series Mounting position RLQ ML1C 177.5 A 128.5 152.5 B 123.5 147.5 172.5 MLU Operating Range Minimum
LP-01 ML1C LC-01 25 32 40 Series Mounting position A B ML1C 177.5 128.5 152.5 123.5 147.5 172.5 D-M5 D-M5W D-M5T Lead wire cap Lead wire clamp Auto switch 14 11 Lead Wire Clamp/Lead Wire Cap (Option) 22 22 B A Lead wire clamp Lead wire cap Series LC-01 LP-01 ML1C (mm) 25 32 40 Mounting position Series A B 124.8 148.8 173.8 ML1C 113.2 137.2 162.2 Minimum Stroke for Auto Switch Mounting Operating
Elbow/Universal Type Flow rate and effective area AS221FM-02 AS221FM-01 Model AS121FM-M5 AS231FM-02 AS231FM-01 AS131FM-M5 3.2, 4, 6 6, 8 Metric sizes 3.2, 4 8, 10 4 6 Tubing O.D. 1/8", 5/32", 3/16" 1/4" 3/16", 1/4" 5/16" 1/4", 5/16" 3/8" Inch sizes 1/8", 5/32" 5/32" 3/16" 38 (1.33) 7 (0.25) Flow rate l/min (ANR) (CFM) 12 (0.42) Controlled flow 0.6 (0.03) 0.2 (0.01) 0.1 (0.006) Effective area
VS3135 A01-01 A01-02 A07-52 q Description Electrical entry VS3145 Solenoid cover Body 100 VAC 200 VAC Grommet A12-01 A12-02 A08-52 w e Spool/Sleeve 24 VDC A01-01-63 A01-02-63 A07-52-63 100 VAC 200 VAC Conduit terminal 24 VDC A12-01-63 A12-02-63 A08-52-63 Replacement Parts Material Part no. VS3135 XT019-6 XT013-13-2 XT010-15 Description VS3145 No.
Port size AMD550 AMD650 AMD850 01 B 06 10 14 B 3 4 1B 1 8 N.C. auto-drain N.O. auto-drain Drain guide Accessory 02 03 B 1 4 B 3 8 04 B 1 2 1 B 1 2 20 2B 1 4 B IN-OUT reversal direction T Element service indicator Option AMD800 to AMD1000 Self-standing type AMD801/901 Piping support type 20 01 AMD 8 20 00 AMD 8 Port size Body size Port size Body size 8 8 20 2B flange 30 3B flange 20 2B flange
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount
Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter, Operation Manual: -
Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø6 One-touch Fitting, Elbow Type, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter, Operation Manual: -
Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter, Operation Manual: -
Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø4 One-touch Fitting, Elbow Type, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter, Operation Manual: -
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: A2 [URJ1/4 (Face Seal Fitting)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: B2 [TSJ1/4 (Compression Fitting)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: C6L (ø6 One-touch Fitting, Elbow Type), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: B (Panel Mount Adapter)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: B
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: B (Panel Mount Adapter)