1% F.S. or lessMaximum load impedance: 300 (Power supply voltage 12 V)600 (Power supply voltage 24 V)Minimum load impedance: 50 Non-voltage input (Reed or Solid state), Low level: 0.4 V or less, 5 ms or longer input3 1/2-digit, 7-segment, 2-color LCD (Red/Green)?2% F.S. ?1 digit (Ambient temperature of 25 ?3C)Lights up when output is turned ON.

1% F.S. or lessMaximum load impedance: 300 (Power supply voltage 12 V)600 (Power supply voltage 24 V)Minimum load impedance: 50 Non-voltage input (Reed or Solid state), Low level: 0.4 V or less, 5 ms or longer input3 1/2-digit, 7-segment, 2-color LCD (Red/Green)?2% F.S. ?1 digit (Ambient temperature of 25 ?3C)Lights up when output is turned ON.

1% F.S. or lessMaximum load impedance: 300 (Power supply voltage 12 V)600 (Power supply voltage 24 V)Minimum load impedance: 50 Non-voltage input (Reed or Solid state), Low level: 0.4 V or less, 5 ms or longer input3 1/2-digit, 7-segment, 2-color LCD (Red/Green)?2% F.S. ?1 digit (Ambient temperature of 25 ?3C)Lights up when output is turned ON.

OFF SUP 1MC 5Ry SGDE servomotor Motor 1MC 1 SGDE servo pack R U V 2 1MC M T 3 W 1CN 4 150 1 2 3 4 5 6 PULS PULS SIGN SIGN CLR CLR Be sure to ground.

HAl AT IDl AMG AFF AM450 1/2B w Make sure to install this product on horizontal piping. If it is installed diagonally, laterally, or upside down, the drainage that is separated by the element will splash to the secondary side.

Stations: 02 (2 Stations), Supply/Return Unit Layout: D (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: S (w/Flow Adj. Valve; Stop Valve: None), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.

Detection nozzle: 1.5 Detection nozzle piping: F type 4 x 2.5 tube 1 m, 3 m, 5 m/G, H type 6 x 4 tube 1 m, 3 m, 5 m Supply pressure: 200 kPa Test conditions ISA3-F ISA3-G 300 60 3 m 1 m 250 50 5 m 1 m 5 m Displayed value Displayed value 200 40 3 m 150 30 100 20 50 10 0 0 0.3 0.25 0.2 0.15 0.1 0.05 0 0.06 0.05 0.04 0.03 0.02 0.01 0 Actual distance [mm] Actual distance [mm] ISA3-H 500 450 3

Mesh: 100/70/50/25 mesh How to Order WF300 02 Port size Mesh 02 Rc1/4 03 Rc3/8 04 Rc1/2 Nil 100 mesh 1-X204 70 mesh 2-X204 50 mesh 3-X204 25 mesh Related Equipment Check Valve INA-14-290/XTO-674Water Regulator WR110--X224/WR110--X215 Body material: Brass Body material: Special brass Best Pneumatics 14-E627 Port size Set pressure range (-X224): 0.08 to 0.39 MPa Rc1/8, Rc1/4 Set pressure

Body Size: 20, Backflow: K (w/Backflow Function), Thread: N (NPT), IN Port Size: 02 (1/4), OUT Port Size: 02 (1/4), Options: M (Round type pressure gauge, with color zone), Set Pressure: 0.05 TO 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Knob: Downward, Pressure Unit: Z (Unit on Product Label: psi, Pressure Gauge: MPa/psi Dual Scale)

Exhaust flow speed Conditions: At max. flow capacity 9 8 Min. required distance Exhaust flow speed m/s 7 (maintenance space) 6 5 AMP420 4 AMP320 3 AMP220 2 1 0 0.4 0.8 1.2 1.6 2.0 Distance from exhaust port m Flow characteristic graph Conditions: Initial element condition 0.05 Distance from exhaust port Max, flow rate capacity line Upstream pressure MPa 0.04 0.5 AMP420 Flow

Stations: 02 (2 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: Rc, Supply Unit Components: S (w/Flow Adj. Valve; Stop Valve: None), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 40 (5 to 40 L/min), Return Unit Components: P (w/o Flow Adj.

Stations: 02 (2 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: Flow Adj.

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A3 (Bracket C), Operation Manual: Y (w/o Operation Manual, w/

Supprressor: Z (w/Light Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Vacuum Pressure Sensor: V (Pressure Switch for Vacuum w/Energy Saving Function, Compound Pressure 1 Output), Output: B (PNP Open Collector), Unit: M (SI Unit Only, kPa), Lead Wire: W (Lead Wire for Switch w/Energy Saving Function; Length: 2 m; Included), Option: B (Adapter Assembly for Bottom Mounting

R/W undetected: NFC reader/writer driver is installed. NFC reader/ writer is not identified or USB is not connected. R/W detection/ R/W no-detection button 5 R/W detected: NFC communication with the wireless unit is available. When the Advanced Card Systems Ltd. ACR1251U/ACR1252U is used. No driver: NFC reader/writer is not identified or USB is not connected.

R/W undetected: NFC reader/writer driver is installed. NFC reader/ writer is not identified or USB is not connected. R/W detection/ R/W no-detection button 5 R/W detected: NFC communication with the wireless unit is available. When the Advanced Card Systems Ltd. ACR1251U/ACR1252U is used. No driver: NFC reader/writer is not identified or USB is not connected.

R/W undetected: NFC reader/writer driver is installed. NFC reader/ writer is not identified or USB is not connected. 5 R/W connection status R/W detected: NFC communication with the wireless unit is available. When the Advanced Card Systems Ltd. ACR1251U/ACR1252U is used. No driver: NFC reader/writer is not identified or USB is not connected.

R/W detected: NFC communication with the wireless unit is available. R/W undetected: NFC reader/writer is not identified or USB is not connected. Installation not performed: NFC reader/writer driver is not installed. R/W detection/ R/W no-detection button 5 Refer to Preparation befor use (2. Preparation befor use (page 7)).

(Default settings) Solenoid Specifications Electrical entry DIN terminal (D) DIN terminal (Y) D, Y Coil rated voltage [V] DC 24, 12 AC (50/60 Hz) 100, 110, 200, 220 Allowable voltage fluctuation 10% of rated voltage*2 Power consumption [W] DC Standard 0.35 (With light: 0.45) 100 V 0.78 (With light: 0.87) 110 V [115 V] 0.86 (With light: 0.97) [0.94 (With light: 1.07)] Apparent