for 1/4" (Inch size) N3: With One-touch fitting for 5/32" N7: With One-touch fitting for 1/4" N9: With One-touch fitting for 5/16" SX 000-50-3AP PG PH SX 000-50-4AFor 45(N) (Flat ribbon cable) SX 000-50-5ASX 000-50-6AT T1 For 45 (Terminal block) SX 000-50-7A1-6-110 Base Mounted Series SX3000/5000 How to Increase Manifold Bases (1) Loosen bolt (a) fixing the manifold base until it begins
LAT3M-50 0 to 50 LAT3F-10 0 to 10 LAT3F-20 0 to 20 0.005 LAT3F-30 0 to 30 LAT3F-50 0 to 50 This determines the condition for when the INF signal is activated. The INF signal turns ON when the pushing force generated by the Card Motor exceeds 0.5 to 5.0 the set value.
1008 1075 VCC-G-D-1 (Applicable fitting VCK ) VCC-G-D-1 2 13 Width across flats: 19 25.5 14 60 VCC-G-D-2 (Applicable fitting VCK ) 0806 0604 9 Width across flats: 17 20.5 14 50 For extending the socket VCC-G-D-1 VCC-G-D-1 113 VCC-G-D-1 VCC-G-D-2 97 17 VCC Series Disassembly/Assembly/ Maintenance Procedure Cleaning Valve Element Special tool part no.: VCC-G-C VCC13-00 (3 port valve) VCC12-
From the 100 mm point, the actuator must start a pushing operation of 10 mm/s speed and 50% or less force. (the pushing distance is up to 5 mm). Then, the actuator should move from the position where the pushing operation was completed (where INP turned ON) to a point 50 mm away at 50 mm/s. (Step Data No.2 is used for this operation).
D Constant Setting range : 0.0 to 99.9sec Min. increment : 0.1sec Indicated content : D constant(Ex. : 0.0sec) Function : Sets differential time used for PID control. D C o n s t a n t M O D E < 0 . 0 s e c When 0 is set, this function becomes invalid. 8-8 Operation 7.
(M5) s Port 5 A ] I "4;f D q-ttFor subplate/type 41, S41,46S46 manibld.
(M5) s Port 5 A ] I "4;f D q-ttFor subplate/type 41, S41,46S46 manibld.
S Without connection port (For manifold) 00 Electrical entry Rated voltage 1 2 3 4 5 6 7 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz 24 VDC 12 VDC 240 VAC, 50/60 Hz CE-compliant G Grommet, Lead wire length 200 mm C Conduit D DIN terminal T Conduit terminal Terminal with indicator light TL DLDIN terminal with indicator light Note1) CE-compliant: Electorical entry
29 18 4(depth 4) 4(depth 4) 4 13 33 42 n QL Model 50 100 150 200 250 300 350 400 50 100 150 200 250 300 350 400 Stroke MXY6 2 3 3 4 39 34 59 54 MXY8 5 5 34 59 2 2 3 4 39 64 54 44 MXY12 2 4 4 5 5 37 67 47 72 52 77 2 3 3 62 42 8-9-12 12 Air Slide Table Long Stroke Type Series MXY Proper Auto Switch Mounting Position (Detection at stroke end) Reed Switch D-A90(V), D-A93(V), D-A96
100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Other Nil A B Non-locking push type Non-locking extended type Locking slotted type 1 2 3 4 5 6 7 9 1 2 3 4 5 6 7 9 Electrical entry Grommet Conduit Conduit terminal DIN terminal DIN terminal with indicator light Option G C T Note) D DL Option Option Option Note) When the electrical entry
D-A9, F9 Rod end nut C1 X L1 Rod end male thread (mm) Bore size (mm) C1 X H1 L1 32 20.5 23.5 28.5 M14 x 1.5 40 20.5 23.5 28.5 M14 x 1.5 50 26 28.5 33.5 M18 x 1.5 (mm) Without auto switch With auto switch A B A B U Z Bore size (mm) Stroke range (mm) C D E F H I J K L M N O P Q S 5 to 50 40 33 9 depth 7 32 50 43 13 16 45 7.5 M8 x 1.25 60 4.5 14 7 34 5.5 1/8 10.5 58.5 31.5 14 75, 100 50 43
(M5) s Port 5 A ] I "4;f D q-ttFor subplate/type 41, S41,46S46 manibld.
15 7.2 7.5 41.5 22 Bracket D ZS-24-D View A Cutting dimensions for panel mounting 43 or more Panel mount 0 +0.5 36 42.4 7.8 25.4 0 +0.5 36 70 or more 47.4 Piping port URJ 1/4 Front protection cover The thickness of the panel is to 3.2mm. 12 Series ZSE F/ISE 50 60 50 60 Description (Common to ZSE50F/ISE50 and ZSE60F/ISE60) 31/2 digit LED kPa Displays current pressure Displays current mode
40 30 20 10 0 100 90 80 70 60 50 40 30 20 10 0 Vacuum pressure [kPa] Vacuum pressure [kPa] ZL3H ZL3H04P ZL3M ZL3M04P Suction flow rate [L/min (ANR)] 100 50 200 150 300 250 350 0 Suction flow rate [L/min (ANR)] 100 50 200 150 300 250 350 0 23 Multistage Ejector ZL3/ZL6 Series Flow Rate Characteristics (Representative value) ZL6M (04P) Supply pressure: 0.35 MPa/0.37 MPa (With valve) ZL6H (
D-M9/D-A9 Auto switch Figure-16 Auto switch D-M9 D-M9W D-M9AVL model D-M9V D-M9WV D-M9AL D-A9 D-A9V Bore size A B A B A B A B 50 23.5 9.0 23.5 11.0 23.5 7.0 19.5 10.5 (13.0) 63 25.5 12.5 25.5 14.5 25.5 10.5 21.5 14.0 (16.5) 80 39.5 19.5 39.5 21.5 39.5 17.5 35.5 21.0 (23.5) The values in brackets are for D-A96.
Coil voltage 1 2 3 4 5 6 9 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Other Note) For the special voltages, please consult with SMC.
FU) Size (mm) (mm) FU 10 20 30 50 HD HC HB HA DF DC DB DA 10 20 30 50 HE 5 6 6 7 Size HC 20H8 28H8 32H8 35H8 63 73 76 87 9.5 13.5 13.5 15.5 35h8 40h8 48h8 54h8 31.5 34.7 34.7 51.7 46h8 61h8 67h8 77h8 24 30 30 34 45h8 60h8 65h8 75h8 15.5 19.5 19.5 21.5 DF (mm) A 50 65 70 80 DF 5 6 6 7 DG HC JB JA J H AY FB FA CB AX DE DD D AW CA AV BE BD BC BB BA AU AA Size 10 20 30 50 15.5 16 18.5 22 4 5
Analog output 4 to 20 mA Load impedance 50 to 600 Accumulated pulse output wiring examples NPN 2 output type LFElAlll NPN + Analog output type LFElClll/LFElDlll Max. 28 V, 80 mA Black OUT1 Load White OUT2 (LFE A only) Load 0 V or Blue DC () 50 ms 50 ms PNP 2 output type LFElBlll Brown DC (+) Black OUT1 Max. 80 mA Load White OUT2 0 V or Load 50 ms 50 ms * When accumulated pulse output is
Accuracy [%F.S.] 50% 50% 50% 40% 40% 40% With 1 1/4" connected With 1 1/2" connected 30% 30% 30% With 3/4" connected Elbow piping (2") Elbow piping (1 1/2") 20% 20% 20% Elbow piping (1") 10% 10% 10% 3% 3% 3% 8 7 6 5 4 3 2 1 0 0% 0% 0% 8 7 6 5 4 3 2 1 0 8 7 6 5 4 3 2 1 0 Straight section [d] Straight section [d] Straight section [d] Straight When piping with diameter smaller than the straight