L (Example) F8NL 5 m . Z (Example) F8NZ Auto switches marked with u are produced upon receipt of order.
_OUT2 6 N.C. 5 N.C. 4 White CH1_OUT2 3 Black C/Q (CH1_OUT1) 2 Blue L 1 Brown L+ 4 Black: 3 Blue: L C/Q (CH1_OUT1) 100 42.5 Front protection cover + Panel mount adapter 53 55 or more 47 37.5 +0.1 0.2 (2) 9.4 42.4 46.4 55 or more 4 x R1 or less Front protection cover Panel mount adapter Panel Waterproof seal m48 conversion adapter + Panel mount adapter (2) 6 1.5 48 Panel fitting dimensions
x J U U D T C 60 G P A H L B Dimensions (mm) Maximum operating tensile and compressive force (N) Center of Maximum screw-in depth P Allowable eccentricity U Applicable bore size Model M A B C D E F K L T J G H Weight (kg) Nominal size Pitch sphere R 180 JAL180-40-150-X530 40 1.5 220 116 55 96 74 48 151 90 89 22 28 70 78 49 3 55000 10.3 200 JAL200-45-150-X530 45 1.5 220 116 55 96 74 48 151
(2-color indicator) 2-wire 12 V 24 V Grommet Yes Relay, PLC 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V 2-wire 12 V 3-wire (NPN equivalent) Reed auto switch 5 V Z76 IC circuit Yes Grommet 100 V Z73 IC circuit Relay, PLC 24 V 12 V 2-wire Z80 100 V or less Lead wire length symbols: 0.5 m Nil (Example) Y7BW 3 m L (Example) Y7BWL 5 m Z (Example) Y7BWZ Solid state auto switches marked
Lead wire length symbols: 0.5 m Nil (Example) M9NW Solid state auto switches marked with v are produced upon receipt of order. 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ For details about auto switches with pre-wired connector, refer to the WEB catalog or Best Pneumatics.
and switching valve to pad by piping system Q2 = S x 11.1 l/min (ANR) Q : Smaller one between the Q1 and Q2 l/min (ANR) S : Effective area of piping (mm 2) Adsorption flow (l/min (ANR)) Air consumption (l/min (ANR)) Vacuum pressure Selection Procedure Tubing length (m) Air consumption From the point at which the valve's effective area of 18 mm 2 and the piping volume of 5 l intersect, the
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VZS VFS VS4 VQ7 EVS Large capacity EVS7-6 (Size 1) 1200 l/min (ANR) EVS7-8 (Size 2) 3000 l/min (ANR) EVS7-10 (Size 3) 5500 l/min (ANR) VFN Cylinder driving size Flow rate 100 160 200 Rubber seal, single type Lightweight Size 1 (3 position): 0.55 kg Size
(d) 4 mm Tube piping length l : 5 m Supply air pressure : 0.3 MPa Supply air dew point : 20C (Atmospheric pressure dew point) Ambient environment: Temperature 25C, Humidity 60% (1) Find the necessary length L from the length selection chart at basic conditions and Kv value.
3150 L/min 60 to 6300 L/min 120 to 12600 L/min Set point range Accumulated flow 0 to 999,999,999,990 L Instantaneous flow 2 L/min 5 L/min 10 L/min Flow Minimum resolution Accumulated flow 10 L 100 L Accumulated volume per pulse (Pulse width = 50 msec.)
drain Max. air flow capacity Note 1) 1,100 L/min(ANR) 200 L/min(ANR) 450 L/min(ANR) Filtration rating 0.3 m (99.9% filtered particle size) Max. 1.0 mg/m30.8 ppm Outlet side oil mist concentration Compressed air quality class Note 2) ISO8573-1:2010 [3:7:3] 45 cm3 Drain capacity 8 cm3 25 cm3 Bowl material Polycarbonate Bowl guard Standard (Polycarbonate) Semi-standard (Steel) Weight 0.10 kg
Positive pressure ISE2 ZSE2 Vacuum Piping specifications Wiring specifications Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Grommet type (Lead wire: 0.6 m) Nil Single mounting R 1/8 01 Grommet type (Lead wire: 3 m) L Single mounting NPTF 1/8 T1 Connector type (
drain Max. air flow capacity Note 1) 600 L/min(ANR) 120 L/min(ANR) 240 L/min(ANR) Filtration rating 0.01 m (99.9% filtered particle size) Outlet side oil mist concentration Max. 0.1 mg/m3(ANR) [before the saturation of oil: 0.01 mg/m3(ANR) or less0.008 ppm] Compressed air quality class Note 2) ISO8573-1:2010 [1:7:2] 45 cm3 Drain capacity 8 cm3 25 cm3 Bowl material Polycarbonate Bowl guard
Theoretical Output (N) Operating pressure (MPa) Rod diameter (mm) Piston area (mm) Operating direction Model 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.15 39.2 33.6 28.0 22.4 16.8 8.4 11.2 56 OUT M L 4 CXS 6 21.7 18.6 15.5 12.4 9.3 4.6 6.2 31 IN 110 94.2 78.5 62.8 47.1 31.4 157 OUT 15.7 M L 6 CXS 10 70.0 60.0 50.0 40.0 30.0 20.0 100 IN 10.0 247 212 177 141 106 70.6 353 OUT 35.3 M L 8 CXS 15 176 151
min L/min L/min L/min L/min Instantaneous Setting/display flow range 1 2 0.5 to 10.5 2.5 to 52.5 5 to 105 10 to 210 25 to 255 L/min L/min L/min L/min L/min flow Min. setting/display unit 0.1 0.5 1 2 5 Flow L/min L/min L/min L/min L/min Accumulated Setting/display flow range 0 to 9 L Flow Min. setting/display unit 1 L Reference condition 3 Standard condition, Normal condition 4 NPN open collector
For single axis Actuator cable type/length Nil Without cable S1 Standard cable 1.5 m S3 Standard cable 3 m S5 Standard cable 5 m R1 Robotic cable 1.5 m R3 Robotic cable 3 m R5 Robotic cable 5 m R8 Robotic cable 8 m*1 Option Caution Nil Without option S With straight type DeviceNet communication plug for JXCD1 T With T-branch type DeviceNet communication plug for JXCD1 [CE-compliant products
LVC DIN terminal: D Conduit terminal: T Cable 6 to 12 LVA F S Q 27.5 34 F (Q) LVH LVD LVQ LQ R C U 25 LVN C (44) R E R TI/ TIL G1/2 E PA G1/2 A H D (S) B B A H D 2-P Port size 2-P Port size PAX 2-M Thread depth N 2-M Thread depth N PB L L K K N.C.
min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Effective area (mm2) Effective area (mm2) Effective area (mm2) 40 0.6 0.1 0.2 30 0.4 5 10 20 0.05 0.1 0.2 10 0 0 0 0 0 10 20 5 10 5 10 0 Number of needle rotations Number of needle rotations Number of needle rotations 15-9-62 Speed Controller for Low Speed Operation Standard Type (Metal Body) Series AS-M Construction Meter-out type
28 50% of max. rated flow [ 2.00] 2.00 L/min (4 L type) [ 8.0] 8.0 L/min (16 L type) [ 20.0] 20.0 L/min (40 L type) [ 50] 50 L/min (100 L type) [ 126] 126 L/min (250 L type) [ P_1] Set value (OUT1) [F 1]/[ oUt1] Page 29 5% of max. rated flow [ 0.20] 0.20 L/min (4 L type) [ 0.8] 0.8 L/min (16 L type) [ 2.0] 2.0 L/min (40 L type) [ 5] 5 L/min (100 L type) [ 12] 12 L/min (250 L type) [ H_1]
S 100 L Flow control valve (With pressure compensation) Enables constant movement even if there are load fluctuations.
size (S) PB Port size G1/2 Compatible heavy-duty cord Cable O.D. 6 to 12 L L K 2-M Thread depth 6 K 2-M Thread depth 6 (mm) Electrical entry P Port size B Model A C D E F K L M Grommet: G Conduit: C DIN terminal: D Conduit terminal: T S 68 71 74 74 U 81 91.5 101 103.5 S 51 54 57 57 Q 98 101 104 104 R 36 44 53 55.5 R 40 48 56 58.5 Q 46 50 52 52 R 36 44 53 55.5 Q 63 66 69 69 R 35 42 51 53.5