) 2 x 5.5 Without spacer With spacer 2 x M5 thread depth M 15 15 Spacer Grommet: GS Flat terminal: F Conduit: C 280 G F F G 11 300 G F Terminal part Flat terminal connector 11 23 9 H C 15 6.5 H C H C G1/2 Terminal: T DIN terminal: D F G Applicable cable O.D.: 6 to 12 F G Width across flats 22 G1/2 32 (44) H 31.5 25 C H C G1/2 J J Dimensions [mm] Model A B Bs C D E F L M P [inch] Grommet:
D-Y7 W (V) 5 6 A B D-Y 9 Red light at ON Green light at ON Red light at ON Green light at ON MHW2-20D MHW2-25D MHW2-32D MHW2-40D MHW2-50D 4 6 15 5 11 4 5 11 4 9 2 4 9 3 7 2 3 6 2 5 2 3 5 2 4 2.8-24
Driver Servo amplifier 24VDC (Note 4, 12) Controller (Note 7) Positioning module CN1 QD75D (Note 7) 21 DICOM CN1 (Note 2) Trouble (Note 6) 20 46 DICOM 48 ALM RA1 14 13 Zero speed detection CLEARCOM DOCOM 23 ZSP CLEAR CR 41 RA2 (Note 12) Limiting torque RDYCOM 12 25 TLC RA3 READY 11 RD PP PG NP NG 49 10 11 35 In-position 24 INP 15 16 RA4 PULSE F PULSE F 10m max. 17 PULSE R PULSE R 18 36 4
rc 1o Indcale thewnnO spec l.ar ons n the specilicalion sheet Note 4) F.r exlenal pr ol oplDn, F ndca|elhe qter.a p otsp6licaton R fordre appricabre var@s as @11 Note 5) The o!
Bore size (mm) 20 25 32 40 20 25 32 40 Clean room series Standard stroke (mm) 10(Relieving type) 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 11(Vacuum type) Specifications Bore size (mm) 10(Relieving type) 11(Vacuum type) 20 20 25 32 40 25 32 40 Fluid Proof pressure Maximum operating pressure Minimum operating pressure Air 1.5MPa (217psi) 1.0MPa (145psi) 0.035MPa (5.1psi) 0.025MPa (3.6psi
Circuit example/Built-in solenoid valve Ball valve Regulator FLUID OUT AIR EXH Filter AIR SUP FLUID IN Air supply Process pump PB1011 Transfer fluid 17-5-166 27 Series PB Process Pump: Built-in Solenoid Valve Type/ Air Operated Type (External Switching Type) Dimensions PB1000 FLUID OUT Rc 1/8 VC 11 OUT VDW 11 VQ 84 72 VX2 Mount with this surface (out port side) on top 7.5 41 60 45 VX Courtesy
, 300, 400, 500 32 131 90 27 16 45 49.5 64 M14 X 1.5 14 4.5 14 40 177 136 27 16 52 57 71.5 M14 X 1.5 24 5 14 50 63 200, 300, 500 193 144 32 20 64 71 85.5 M18 X 1.5 22.5 7 18 200, 300, 500 194 145 32 20 77 84 98.5 M18 X 1.5 21 7 18 P T* X M N O Q Z L Bore size (mm) 32 40 50 63 Rc(PT) 1/8 57.5 41 34 5.5 M6 X 1 56 30 14 Rc(PT) 1/8 64.5 41 40 5.5 M6 X 1 62 30 14 Rc(PT) 1/4 76.5 49 50 6.6 M8 X
5 1 10 20 30 40 50 100 200 300 400 1 5 4 10 20 30 40 50 100 200 300 400 5 10 50 100 10 50 100 Eccentric distance l (mm) Eccentric distance l (mm) Stroke (mm) Stroke (mm) l = 300mm Graph 4 l = 200mm Graph 3 v = 150mm/s or less Graph 7 v = 200mm/s or less Graph 8 20 300 300 200 200 MGF100 MGF100 20 100 100 MGF100 10 50 40 50 40 MGF63 MGF100 Load weight m0 (kg) MGF63 Load weight m0 (kg) Load
For pipe fitting 4B through 6B Applicable fittings For pipe fitting 3/4B through 3B Welding Welding Piping B Reducing tees B 1 1 x 1 x 1 24 or more 11/4 11/2 11/4 x 11/4 x 1 1B socket 11/2 x 11/2 x 1 cut in half 2 x 2 x 1 2 21/2 x 21/2 x 1 21/2 3 x 3 x 1 3 Pipe 4B through 6B Reducing tees B Socket Pipe : JIS B 2301 : JIS B 2302 : JIS B 3452 Without flash 16-12-8 4 Paddle Style Flow Switch
N None 1 2 n T 7 Digital Gap Checker With Control Unit ISA3 Series 3-Color Display RoHS How to Order G C N M B 2 ISA3 L 1 Rated distance range F 0.01 to 0.03 mm G 0.02 to 0.15 mm H 0.05 to 0.30 mm 2 port solenoid valve Rated voltage Piping specifications Output specifications Nil 24 VDC 1 *11 100 VAC 2 *11 110 VAC *11: Made to Order N NPN output P PNP output Supply side Detection side Unit
Drain outlet One-touch fitting ([Thread symbol: N] 1/2 inch [Thread symbol: Nil] 12 mm) Earth leakage breaker (Inside of front panel) Power cable outlet ( Electric wire diameter: IDFB60/70: 0.35 to 0.43 in (9 to 11) ) IDFB80/90: 0.71 to 0.91 in (18 to 23) IDFB60-11: Power cable with plug [Length: 110 inch (2.8 m)] 8 B IDFB Series Specific Product Precautions 1 Be sure to read this before
Fittings & Tubing Air Cylinders Rotary Actuators Lead wire length 300 mm 2-M5 x 0.8 4(A), 2(B) port Direct manual override Indicator light 0.5 0.5 4 (11) 11 2 5.5 0.6 0.6 15 5.3 5.3 13 34 33 25.5 29 6 3 L plug connector (L) 21.5 4 2-3.5 mounting hole 28.5 49 50.5 2-M5 x 0.8 1(P), 3(R) port 3 1 Air Preparation Equipment Pressure Control Equipment Flow Control Equipment Pressure Switches/ Pressure
2 12 Mount with this surface up FLUID OUT Rc, NPT, G 1/8 84 72 60 41 7.5 45 2 x 4.5 Mounting hole Manual override pin 66 16 16 Foot (Option) 3 2 x M4 x 0.7 Female mounting threads Thread depth 6 12 Silencer: AN120-M5 (Option) 8 AIR SUP Rc, NPT, G 1/8 16 Lead wire length: Approx. 570 mm FLUID IN Rc, NPT, G 1/8 8 18 12 11 11 AIR EXH M5 x 0.8 Thread depth 8 Air Operated PB1013A 18 1.5 10 Mount
22 20 44 16 11 15 6 27 71.5 60 42 22 21 150.5 8 M8 x 1.25 25 to 800 25 to 650 50 35 12 13 10 59 40 27 11 27 21 52 20 10 17 9 32 80.5 70 46 24 28.5 162.5 11 M8 x 1.25 25 to 800 25 to 650 60 35 15 18 10 67 40 26 27 23 64 20 13 17 9 32 98.5 85 48.5 24 28.5 174 11 M10 x 1.25 13.5 25 to 750 25 to 600 70 40 17 23 14 72 52 30 32 23 78 25 15 21 11 37 117.5 102 55 26.5 36 189 13 M12 x 1.75 16.5 25
(Display item), Set value (Threshold value) Sub screen Set value (Threshold value) Hysteresis value Visualization of settings Peak value Bottom value Delay time Piping Applicable fluid Series Output type Enclosure Copy function 1/4 (R, NPT, G) (URJ1/TSJ2) M5 female thread 1/8 (R, NPT) ZSE20(F)/ ISE20 1 output IP40 p. 9 ZSE20A(F)/ ISE20A 2 outputs Analog output (Voltage/Current) IP40 p. 11
Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 10, 11, 12 12, 13 Flow rate [L/min (ANR)] 1000 Flow rate [L/min (ANR)] 1000 08, 09 10, 11 500 500 06, 07 0 0 0 5 10 0 5 10 Number of needle rotations Number of needle rotations The numbers above the flow rate characteristic curves in the charts show the applicable tubing outside diameter as defined by the product number.
) 2-P1.8 2-M3 X 0.5 (Pilot port) A B 11 1.5 (Mounting holes) 2-3.2 17.5 18.5 A B (Non-locking) Manual override (Non-locking) Manual override 14 36 18.5 21 41.6 13.5 15 41.6 28.5 R2 P R1 21 R P R 13 11 0.5 10 5 5 1 (Bleed port) 210 10 7 7 1 (Bleed port) 228 5-M3 X 0.5 (Piping port) 5-M5 X 0.8 (Piping port) 3 position closed center/exhaust center/pressure center: SYJA3 20-M3(-F) 3 position
Vertical Horizontal l: Load eccentricity m Mounting position m L L to 100 to 300 Maximum speed mm/s to 500 to 100 to 300 to 500 Load eccentricity lmm 100 50 200 100 50 200 100 50 200 1 2 3 4 5 6 7 8 9 10 11 12 Selection graph L: Overhang (the distance from the cylinder shaft center to the load center of gravity) The direction of L can also be a diagonal direction .
0.5 (Pilot port) A B 11 1.5 17.5 (For mounting) 2 x 3.2 equivalent (18.5) A B Manual override 14 36 (18.5) (21) Manual override 41.6 13.5 15 41.6 28.5 21 R2 P R1 13 R P R (11) (0.5) 10 5 5 2 x 1 (Bleed port) 10 10 7 7 2 x 1 (Bleed port) M3 x 0.5 (Piping port) 28 M5 x 0.8 (Piping port) 3 position closed center/exhaust center/pressure center SYJA3 20-M3(-F) 3 position closed center/exhaust
/8 NPT1/8 G1/8 Rc1/4 NPT1/4 G1/4 12-CY3B15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 12-CY3B20 20 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 (Both sides) 1300 25 12-CY3B25 Non-lube 32 12-CY3B32 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 12-CY3B40 40 Note 1) Stroke exceeding the standard stroke but below the maximum possible stroke is available