1500 200 400 600 800 Flow rate L/min (ANR) Flow rate L/min (ANR) Flow rate L/min (ANR) AR30(K)-B Rc3/8 AR40(K)-B Rc1/2 AR40(K)-06-B Rc3/4 0.6 0.6 0.6 0.5 0.5 0.5 Outlet pressure (MPa) Outlet pressure (MPa) Outlet pressure (MPa) 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0 00 0 0 1000 2000 3000 4000 5000 0 1000 2000 3000 500 1000 1500 Flow rate L/min (ANR) Flow rate L/min (ANR) Flow
In locations at altitude of 3000 m or higher (Except during storage and transportation) * For altitude of 1000 m or higher Because of lower air density, the heat radiation efficiencies of the devices in the product will be lower in the location at altitude of 1000 m or higher.
1500 200 400 600 800 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] AR30(K)-B Rc3/8 AR40(K)-B Rc1/2 AR40(K)-06-B Rc3/4 0.6 0.6 0.6 0.5 0.5 0.5 Outlet pressure [MPa] Outlet pressure [MPa] Outlet pressure [MPa] 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0 00 0 0 1000 2000 3000 4000 5000 0 1000 2000 3000 500 1000 1500 Flow rate [L/min (ANR)] Flow rate [L/min (ANR
Output indication mode [Output Ratio] Setting range : -100 to 100% Min. increment : 1% Indicated content: Thermo module output ratio (Ex.: -73%) Function: Indicates Thermo module output ratio with O u t p u t R a t i o M O D E < 7 3 % increment of 1%. + is not indicated but + means heating and means cooling. 11.Upper/Lower Temp.
10 32 . 12 33 . 13 1LECGPR1 . 13 2DIN LECGPR1D . 13 34 . 14 1 . 14 2 . 14 4 . 15 41 ADDRESS,B RATE . 15 42 CN2SW . 16 43 LEC . 17 44 SIEMENS PLC S7 . 19 5 . 21 51 CN4: . 21 52 CN3: . 21 53 CN1:CONT . 21 54 CN2:PC/TB . 22 1 - 6CN . 23 61 . 23 62 . 23 63 . 24 . 25 7CN3: . 26 8CN1:IF CONT . 27 81 . 27 82 . 29 9CN2:TB/PC . 30 91 . 30 10LED . 31 101 LED . 31 102 IF LED . 31 11
0 e 1 New PFA Body 2 New PFA Sensor 3 Super PFA Tube 4 PPS Housing A 5 PPS Housing B 6 PPS Housing C 7 POM Bushing 8 PPS Cap 9 FKM Gasket 10 FKM O-ring 11 Stainless steel 304 Thread 12 PVC Lead wire !1 q t i PF2D540 o !0 u !0 !2ywr e !
(mm) D-A9, D-A9V D-F9, D-F9W D-F9V, D-F9WV Bore size (mm) A A W B W B W A B 20 25 32 22 22 13 (10.5) 19 18 9 19 11 15 24.5 24.5 9 (6.5) 15 20 5 15 7 11 26.5 26.5 11.5 (9) 17.5 22.5 7.5 17.5 9.5 13.5 Values in ( ) are dimensions for D-A93 type.
Confirm that this value is less than 1/20 of the effective torque. 20 x 9.8 x (m1 + m2) x H/1000 20 x 9.8 x (0.07 + 0.05) x 10/1000 = 0.24 Graph 3
When bank 2 is selected 0 0001 0010 0011 0100 0101 0110 0111 1000 1001 BCD Ex.) 1294.53 is expressed as follows. 0001 0010 1001 0100 0101 0011 16 17 18 19 20 Bank 2 Bank 3 Bank 4 11 12 13 14 15 6 7 8 9 10 1 2 3 4 5 Bank 1 RS-232C This is the interface standard for the serial transmission method, which is standard equipment on a personal computer.
11 12 2 wire 3 wire 56 Solid state switch D-F7 4 wire 56 14 Write "L" at the end of the part number for 3 meters of lead wire.
Note 2) For the specifying way of ordering numbers for the solenoid valve with adapter assembly, refer to page 10-16-4. 10-16-19 20 Series MVGQ Proper Auto Switch Mounting Position (Detection at stroke end) Operating Range Bore size (mm) Auto switch model 16 100 12 20 25 32 40 50 63 80 D-Z7/Z8 8.5 14 7.5 9.5 9.5 11 11 11 13 13 A B D-Y59/Y69/Y7P/Y7PV D-Y7W/Y7WV 6 11.5 5 6 6.5 8.5 8.5 9 10
(Page 9) 6 Bushing (bearing) 1000 fR[N] 100 Lateral load applied to rod end 100 80 63 10 50 40 1 0 500 1000 1500 Cylinder stroke [mm] Fig. 1 Allowable lateral load applied to rod end C a u t i o n Be certain to align the rod axis with the load and direction of movement when connecting.
It will cause failure or malfunction. 11. Do not use the product in an area where a magnetic field is generated. It will cause failure or malfunction. 12. Do not install the product in an environment containing flammable gas, explosive gas, or corrosive gas. It could lead to fire, explosion, or corrosion. 13.
CN1IF(CONT) 18 - (LEC)(LEC) 5.4 CN2PC/TB (LEC)(LEC-T1-3*G*)(LEC-W2) CN2SWOFF(LEC)(LEC) (LEC-T1-3*G*)(LEC-W2) (1) CN2 (3m) (2) (USB) 120.3 120.3 mm mm 200 200 mm/s mm/s USB (A-miniB type) 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 CN2 () 9.
10,11,12 08,09 1000 10 15 8 500 06,07 10 6 500 4 5 2 0 0 5 10 0 5 10 0 Number of needle rotations Number of needle rotations 15-9-85 12 Construction ASD230F ASD330F/430F ASD530F/630F ASD530F02 Component Parts No.
) [P_1] OUT1 [ 500] 500 L/min(PFMB7102) [F 1][oU1] [1000] 1000 L/min(PFMB7202) 28 [ 25] 25 L/min(PFMB7501) [H_1] OUT1 [ 50] 50 L/min(PFMB7102) [100] 100 L/min(PFMB7202) [CoL] OUT1 [SoG] ONOFF [oU2] OUT2 2 [HYS] [2ot] OUT2 2 [2_P] [ 250] 250 L/min(PFMB7501) 2 [P_2] OUT2 [ 500] 500 L/min(PFMB7102) [F 2][oU2] 36 [1000] 1000 L/min(PFMB7202) [ 25] 25 L/min(PFMB7501) 2 [H_2] OUT2 [ 50] 50 L/min
Bushing CDQ2B only A set of Nos.11, 12 and 13 from the table above 180 9 CQ2WB180-PS Magnet Nickel plated 200 10 Rolled steel CQ2WB200-PS Rod end nut Mounting 1in = 25.4mm Mounting/Through hole type mounting bolts are available. How to order: Add "Bolt" in front of the bolts to be used.
(l/min (ANR)) Flow (l/min (ANR)) Effective area (mm2) Effective area (mm2) Flow (l/min (ANR)) 300 06 1.0 2 4 200 50 100 0.5 1 2 100 0 0 0 0 5 10 0 5 10 0 5 10 Needle rotation (Turns) Needle rotation (Turns) Needle rotation (Turns) ASD530F ASD630F 1000 1500 14 20 10, 11 12 Flow (l/min (ANR)) Effective area (mm2) Effective area (mm2) Flow (l/min (ANR)) 12 1000 10 8 10, 11, 12 08, 09 15 500
V100-49-15 D V115 Light/surge voltage suppressor Rated voltage Nil Without light/surge voltage suppressor With surge voltage suppressor (Non-polar type) With light/surge voltage suppressor (Non-polar type) S Z 5 24 VDC 6 12 VDC Cable length 1 100 VAC 50/60 Hz 1 2 3 4 7 300 mm 500 mm 1000 mm 2000 mm 5000 mm 2 200 VAC 50/60 Hz DOZ is not available.
B C d H MQ10-M MQ16-M MQ20-M MQ25-M MQ28-M NTJ-015A NT-015A NT-02 NT-03 NT-04 8 9.2 6 15.5 5 9.2 M5 x 0.8 4 10 20.5 10 8 8 9.2 8 16.5 6 11.5 M6 x 1.0 5 16 22.5 16 10 8 9.2 10 18.5 6 15 M8 x 1.25 5 20 24.5 20 13 10 11.5 12 22.5 11 19.6 M10 x 1.25 6 25 33.5 25 17 14 16 16 28.5 12 25.4 M14 x 1.5 8 30, 40 40.5 30, 40 22 Applicable bore size (mm) Part no.