VCHC Connection Female Thread: Rc, NPT, NPTF ASR ASQ Uni thread size Wrench tightening angle after hand-tightening [deg] Tightening torque [Nm] 1/8 30 to 60 3 to 5 1/4 30 to 60 8 to 12 3/8 15 to 45 14 to 16 1/2 15 to 30 20 to 22 3.
Supply port PD (mm) A B C EA EB FA FB FD FE FF FG GA GB GD 83 111 155 200 256 D FC GC 6 8 11 15 Model MIW8-8 MIW12-12 MIW20-20 MIW25-25 MIW32-32 M3 x 0.5 M3 x 0.5 M5 x 0.8 M6 x 1 22 34 43.5 58 73 28 37 54 71 80 9 12.5 16.5 20 24.5 2.6 3.3 5.1 6.8 8.6 4 4.5 6.5 10 12.5 7 9.5 12.5 17 22 16 21 29.5 40 47 15 19 25.5 37 51 34 44 64 84 95 18 23 28.5 41 55 57 26 35 48.5 66 87 6 (Effective depth
M36 x 1.5 22 37.5 58.5 37.5 59.5 30 34 43.9 5.4 15.4 55 2.3 27.3 36.5 17.5 6 AR25-A 1/4, 3/8 1/8 53 70.4 23.5 22 M36 x 1.5 22 37.5 58.5 37.5 59.5 30 34 44.3 5.4 15.4 55 2.3 30.3 36.5 17.5 6 AR30-A 1/4, 3/8 1/8 53 83.5 27 28.5 M45 x 1.5 28.5 37.5 65 37.5 66 41 36 46 6.5 24 65 2.3 32.5 45.5 22.5 7 AR40-A 1/4, 3/8, 1/2 1/8 70 100 33.5 34.5 M52 x 1.5 34.5 42.5 72 42.5 72 50 38 54 8.5 26.5 70
Supply port PD (mm) D FC GC 6 8 11 15 A B C EA EB FA FB FD FE FF FG GA GB GD 83 111 155 200 256 Model MIW8-8 MIW12-12 MIW20-20 MIW25-25 MIW32-32 M3 x 0.5 M3 x 0.5 M5 x 0.8 M6 x 1 22 34 43.5 58 73 2.6 3.3 5.1 6.8 8.6 9 12.5 16.5 20 24.5 28 37 54 71 80 4 4.5 6.5 10 12.5 7 9.5 12.5 17 22 16 21 29.5 40 47 15 19 25.5 37 51 34 44 64 84 95 18 23 28.5 41 55 57 26 35 48.5 66 87 6 (Effective depth
Model Width 22 3.3 ftlbf (4.5 Nm) 41.5 MXP12-15 2.7 times 18.5 1.22 ftlbf (1.65 Nm) 68 96 Note1) MXF12-20 All dimensions in mm. Note 1) At fully stroke extended. MXPJ6 Mounting on equipment is possible from top side (through hole) and bottom side body tapped.
g 1 m: Approx. 105 g 2 m: Approx. 165 g 3 m: Approx. 225 g 5 m: Approx. 345 g 10 m: Approx. 645 g 0.5 m: Approx. 75 g 1 m: Approx. 105 g 2 m: Approx. 165 g 3 m: Approx. 225 g 5 m: Approx. 345 g 10 m: Approx. 645 g Weight 224-1 A Communication Cable/Connector M12 Example of Connection PLC !
PAX1000, PA3000, PA5000 Proper tightening torque Nm Connection threads 12 to 14 Rc 1/4 22 to 24 Rc 3/8 28 to 30 Rc 1/2 28 to 30 Rc 3/4 PB1000 Proper tightening torque Nm Connection threads 1/6 turn after tightening by hand M5 2 to 3 Rc 1/8 Since the threaded sections of the PB1000 are resin, take particular care not to tighten any more than necessary.
Tube To Male Pipe: ,15' ELBOW 1/4 1t8 7t16N .78 ,co .188 'lt4 1t4 7116-20 .75 .84 .188 5/16 118 112-20 . / c .65 .220 5/16 1t4 'U2-20 .75 .81 .220 g8 1t4 5/8.18 .89 .86 .283 U8 3i8 5/8-18 .91 .93 .283 3ri8 112 Consult factory tor inlormation 112 3/8 u4-16 1 .06 .95 .408 112 1t2 3V416 1.00 .97 .406 5/8 112 7lS-14 1.21 1 . 1 6 .502 Steel Terminal Bolt: FEMALE BULKHEAD' * Zinc Dichromate Plating
Optional accessory Blank plate ass'y: DXT199-22-1A EXH Relocation Spacerl DXT199-29-2TA SUP Relocation Spacar: (only for type 41, 42, 43): DXTl99-35-1TA 20 stations NVVsZs41-168'1.OlT --TStations a lf there are mof6 than 10 stations, supply 6ir and exhaust frctn both sid6s of manitold. NVV5Z5-4 2-( 05 ) 1 -r87T) Y -r.Stationsa asize ot A, B port E-?
/Dimensions IDF4E to 8E IDU3E, 4E Transformer installed separately A 75 B D 52 385 15 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 4-13 C 515 45 Base integrated with a transformer Base integrated Applicable dryer Part no.
Double acting, Single rod Double acting, Double rod CE1 50 63 10, 15, 20, 25, 30, 35 40, 45, 50, 75, 100 CE2 80 100 ML2B C J G5-S CHQB CHQWB CV MVGQ CC For details, refer to the catalog CAT. E111.
Refer to"LECSC Operation Manual, chapter 6 for details of each parameter. -22- 5.3.1 Change of parameter block To enable settings for all parameters. Select Basic settings (list) tab and change PA19 value to 000C. Click the PA19 row then click Selected Items Write. Cycle the power off, then on for parameters for this driver to be enabled. Please click Read".
Refer to"LECSC2-T Operation Manual, chapter 6 for details of each parameter. -22- 5.3.1 Change of parameter block To enable settings for all parameters. Select Basic settings (list) tab and change PA19 value to 000C. Click the PA19 row then click Selected Items Write. Cycle the power off, then on for parameters for this driver to be enabled. Please click Read".
Changeable range output 5 V (10 V) 20 mA At the time of shipment 1 V (0 V) 4 mA Grease-free 10% 100% 105% Display 0% Application example Analog Functions Adjustment point: 75 L/min , 100 L/min output pp. 27, 28 When 5 V output is required from the flow switch at 75 L/min, use a sensor that outputs 1 to 5 V at 1 to 100 L/min. 5 V Change Output operation Key-lock function Forced output function
) Ambient and fluid temperatureMax' 120'F(Max. 50'C) Response time 2 pooition single/double 20ms or less at 75 PSI (Skgf/cm'?) 3 position 40ms or less at 75 PSI (Skgf/cm'?)
40 35 10 M5 56 75 2.3 30 6.5 10.5 31 37 VXS24 1/2 28 70 37.5 94 35 14 22 48 35 14 M5 56 75 2.3 34 6.5 10.5 35 41 VXS25 3/4 33.5 71 38.5 105.5 40 17 24.5 62 33 15.2 M6 70.5 92 2.3 39 6.5 10.5 43 46 VXS26 1 42 95 49.5 111.5 40 20 24.5 66 37 17.2 M6 70.5 92 2.3 41 6.5 10.5 45 48 13.5 Electrical entry Grommet DIN terminal Conduit terminal Conduit Q R Q R S Q R S T Q R VXS23 1/4, 3/8 29.5 66
H 28 30 36 44 54 E 22 21 26 F 45 55 58 65 76 G 33 42 44 50 61 D 34 46 63 67 78 A 59 78 107 110 134 B 20 29 39 42 53 C 40 53 70 75 90 I 45 55 63 69 81 Model Piping port VHS20 VHS30 VHS40 VHS40-06 VHS50 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1938 Series VHS20/30/40/50 Specific Product Precautions Be sure to read before handling.
[CR][LF] :01 06 0052 0032 75 [CR][LF] Set at 0.50 deg.C.
OFF (SVRE OFF )[LK RLS]DC24V LK RLS LK RLSDC24V LK RLS (EMG) /(LEC ) -73- 18 18.1. / JXC91EEPROM1,000,000 -74- 18.2 ON 5 () -75- 18.3 18.4 () -76- 18.5 18.6 D(100) 18.7 -77- 19 ,, (), YES NO JXC LED 1 MSNS 2 ALM 3 (LEC-W2) 4 5 -78- No. 3(P.12) 5(P.23) SVON ON PWR() 1 LED 5. (P.23) 6.
Optional accessory Blank plate ass'y: DXT199-22-1A EXH Relocation Spacerl DXT199-29-2TA SUP Relocation Spacar: (only for type 41, 42, 43): DXTl99-35-1TA 20 stations NVVsZs41-168'1.OlT --TStations a lf there are mof6 than 10 stations, supply 6ir and exhaust frctn both sid6s of manitold. NVV5Z5-4 2-( 05 ) 1 -r87T) Y -r.Stationsa asize ot A, B port E-?