The pressure in the pilot chamber e increases and operates on the upper surface of the diaphragm r. As a result, the air supply valve t linked to the diaphragm r opens, and a portion of the supply pressure becomes output pressure. This output pressure feeds back to the control circuit i via the pressure sensor u.
AS2052F-A AS1002F-A AS2002F-A 500 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 01, 23, 03, 04, 06, 07 100 08, 09 06, 07 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 400 200 06, 07 03, 04 300 50 200 100 100 0 0 0 0 5 10 0 5 10 0 5 10 Number of needle rotations Number of needle rotations Number of needle rotations AS3002F-A AS4002F-A 1500
K F 10 AW B 30 03 BG JN K F 21 AW B 30 03 BG JN Copper, fluorine and silicone-free + Low particle generation q r t y w e Filter regulator Option/Semi-standard: Select one each for a to g.
7 r !3 o r !0 w u t y !2 !3 !1 q i !4 e Meter-in type Meter-in type AS ASP ASN AQ ASV AK ASS ASR ASF Component Parts: Elbow Type Component Parts: Universal Type No. Description Material Note Body A Handle Body B Needle Gasket Seat ring Lock nut U seal Cassette Seal O-ring O-ring O-ring No.
Size: 3/8, Thread: NPT, Port Size: 3/8-AV3000 only, Option: None, Voltage: 24VDC, Lead Wire: Type Y DIN Terminal Without Connector, Surge Suppressor: -, Manual Override: -, Flow Direction: -, Q: -
Size: 3/8, Thread: NPT, Port Size: 3/8-AV3000 only, Option: None, Voltage: 12VDC, Lead Wire: DIN Terminal, Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Flow Direction: Right to Left, Q: -
Size: 3/8, Thread: Rc, Port Size: 3/8-AV3000 only, Option: Pressure Gauge, Voltage: 24VDC, Lead Wire: DIN Terminal, Surge Suppressor: Light+Surge Suppressor, Manual Override: Locking (Lever Type), Flow Direction: Right to Left, Q: -
Size: 3/8, Thread: NPT, Port Size: 3/8-AV3000 only, Option: None, Voltage: 24VDC, Lead Wire: DIN Terminal, Surge Suppressor: Light+Surge Suppressor, Manual Override: Locking (Lever Type), Flow Direction: Right to Left, Q: -
Size: 3/8, Thread: NPT, Port Size: 3/8-AV3000 only, Option: None, Voltage: 24VDC, Lead Wire: Type Y DIN Terminal, Surge Suppressor: Light+Surge Suppressor, Manual Override: Locking (Slotted), Flow Direction: Right to Left, Q: -
Size: 3/8, Thread: NPT, Port Size: 3/8-AV3000 only, Option: None, Voltage: 24VDC, Lead Wire: DIN Terminal w/o Connector, Surge Suppressor: Light+Surge Suppressor, Manual Override: Locking (Lever Type), Flow Direction: -, Q: -
Size: 3/8, Thread: G, Port Size: 3/8-AV3000 only, Option: None, Voltage: 24VDC, Lead Wire: Type Y DIN Terminal, Surge Suppressor: None, Manual Override: Locking (Lever Type), Flow Direction: Right to Left, Q: -
Size: 3/8, Thread: Rc, Port Size: 3/8-AV3000 only, Option: None, Voltage: 110~120VAC, Lead Wire: DIN Terminal w/o Connector, Surge Suppressor: -, Manual Override: -, Flow Direction: -, Q: -
Size: 3/8, Thread: Rc, Port Size: 3/8-AV3000 only, Option: None, Voltage: 24VDC, Lead Wire: DIN Terminal w/o Connector, Surge Suppressor: Light+Surge Suppressor, Manual Override: -, Flow Direction: -, Q: -
Size: 3/8, Thread: Rc, Port Size: 3/8-AV3000 only, Option: None, Voltage: 24VDC, Lead Wire: Type Y DIN Terminal Without Connector, Surge Suppressor: -, Manual Override: -, Flow Direction: -, Q: -
Size: 3/8, Thread: Rc, Port Size: 3/8-AV3000 only, Option: None, Voltage: 12VDC, Lead Wire: DIN Terminal w/o Connector, Surge Suppressor: -, Manual Override: -, Flow Direction: -, Q: -
Size: 3/8, Thread: NPT, Port Size: 3/8-AV3000 only, Option: None, Voltage: 110~120VAC, Lead Wire: DIN Terminal, Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Flow Direction: Right to Left, Q: -
Size: 3/8, Thread: NPT, Port Size: 3/8-AV3000 only, Option: None, Voltage: 110~120VAC, Lead Wire: DIN Terminal, Surge Suppressor: Light+Surge Suppressor, Manual Override: Non-locking Push Style (Flush), Flow Direction: Right to Left, Q: -
Size: 3/8, Thread: NPT, Port Size: 3/8-AV3000 only, Option: None, Voltage: 24VDC, Lead Wire: DIN Terminal w/o Connector, Surge Suppressor: Light+Surge Suppressor, Manual Override: Non-locking Push Style (Flush), Flow Direction: Right to Left, Q: -
Size: 3/8, Thread: NPT, Port Size: 3/8-AV3000 only, Option: None, Voltage: 24VDC, Lead Wire: Type Y DIN Terminal, Surge Suppressor: Light+Surge Suppressor, Manual Override: Locking (Lever Type), Flow Direction: Right to Left, Q: -
Size: 3/8, Thread: Rc, Port Size: 3/8-AV3000 only, Option: Pressure Gauge, Voltage: 24VDC, Lead Wire: DIN Terminal, Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Flow Direction: Non (Left to Right), Q: CE Marked