that has a weight that is proportionate to the gripping force.
Use a tightening torque of 0.05 to 0.1 Nm. As a rough guide, tighten the screw an additional 90 after feeling a tight resistance. As a rule, it should be turned about 90 beyond the point at which tightening can be felt. 0.5 0.2 0.3 MHL2-20D 0.5 0.2 0.2 MHC MHL2-25D 0.2 0.1 0.2 MHL2-32D 0.4 0.4 0.7 MHT MHL2-40D 0.2 0.4 0.7 MHY MHW MRHQ Misc.
AMH550 AMH150 I Air pressure 0.3MPa ",0.06 '" 0.06 a. ::;; Inlet air pressure 0.3MPa r-a. /;57o.7MPa ::;; ~ / // 0.5MPa ~ ./' 0.7MPa
Construction Diaphragm Seat Body 1112 B Diaphragm Valve for Ultra High Purity Manually operated type Series AZ3652 & 4652 inch (mm) Dimensions AZ3652 & 4652 Ports: 2PW (Welded) Ports: 2P (Machined) 1.5 (38) 1.5 (38) BAR STOCK BODY Note) FORGED BODY 0.44 (11.2) 2.17 (55) 2.17 (55) 0.44 (11.2) A A B A A Connections: MV, FV Connections: MV B A A A A Connections: TW Connections: TW 1.0 (25.4)
No malfunction when tested with a drop tester in the axial direction and at a right angle to the armature, one time each in energized and de-energized states. Note 5) Consult P/A regarding drip-proof specifications (equivalent to IP54) .
If a directional switching valve (solenoid valve, mechanical valve, etc.) is mounted on the supply side of the regulator and repeatedly switched ON and OFF, wear of the nozzle/flapper section will be accelerated and a discrepancy in the setting value may occur. Therefore, avoid using a directional switching valve on the supply side.
M B This is the amount of deflection on a dial gauge when the guide block travels a full stroke with the body secured on a reference base surface.
3 m 2 250 L/min PVC 25 A ZS-40-U25 25 A PVC 1 PVC 30 A ZS-40-U30 30 A PVC 1 25 A ZS-40-U25-A 1 M5x80 2 30 A ZS-40-U30-A 1 M5x65 2 PVC 1~2% -12No.PF-OMM0004-D 1 DC+ 2 OUT2 3 DC4 OUT1 M8 IN OUT OUT1OUT2 ON UP ON/OFF SET DOWN ON/OFF -13No.PF-OMM0004-D F.S.( 1~5V F.S.=5[V]1[V]4[V] 1F.S.4[V]10.04[V] 1-5V 1-5V 4-20mA (HYS) ON OFF 90% , () () ,, ,, 10 L/min 10 L ON OFF ON OFF
Features 2 Model Selection 1 Obtain the correction factor for the temperature from data A or B and the correction factor for the air pressure from data C. Temperature Data A or B = Series IDU: Data A IDF1D to 240D: Data B-1 IDF 370B: Data B-2 Air pressure Data C = Series IDU and Series IDF: Data C 2 Calculate corrected air flow by using A or B and C.
Because tube fittings are provided, use a tube with a bore of 10mm, and keep the overall pipe length within 5m. AM850 type (N.O) Use a tube with a bore of 9mm or more, and keep the overall pipe length within 2.8m.
Switch operating range Stroke (mm) 20 41 29 47 35 Type 25 46.5 34.5 30 55 43 10 31 19 15 36.5 24.5 A B A B A B MXP10 Auto switch MXP12 3 Screwdriver (Grip diameter 5 to 6mm) MXP16 2 Color indication solid state switch D-F9BW(V), D-F9NW(V), D-F9PW(V) mm Switch operating range Stroke (mm) 20 42 28 48 34 Type 25 47.5 33.5 30 56 46 10 32 18 15 37.5 23.5 A B A B A B MXP10 MXP12
equipment such as a voltmeter.
When a filter element is used repeatedly, clean it with air blow or wash it with a neutral detergent. (For 40 m, For 80 m) Check the condition of the element and replace the element with a new one when the specifications are not satisfied.
Because tube fittings are provided, use a tube with a bore of 10mm, and keep the overall pipe length within 5m. AMH850 type (N.O) Use a tube with a bore of 9mm or more, and keep the overall pipe length within 2.8m.
Because tube fittings are provided, use a tube with a bore of 10mm, and keep the overall pipe length within 5m. AM850 type (N.O) Use a tube with a bore of 9mm or more, and keep the overall pipe length within 2.8m.
If it is used with anything other than dry air (such as air containing moisture), the drainage will flow in, and the color change indicator function will not operate properly. e Make sure to install a mist separator (AM Series), a micromist separator (AMD Series), or a micromist separator with a prefilter (AMH Series) on the primary side. r The bracket that is provided with the product is
In order to prevent a malfunction or diaphragm damage caused by debris or cutting chips in the fluid, install a filter with approximately 100 mesh on the inlet side of a flow switch. C (COM) A (N.O.) Color of lead wire Black Symbol Contact C Z I SE3 Common A White Normally Open B (N.C.)
The element could be damaged if the difference in internal and external pressures exceeds 0.1MPa. w Do not use it with anything other than dry air (such as air containing moisture). e Make sure to install a micromist separator (AMD Series), a micromist separator with a prefilter (AMH Series) or a supermist separator (AME series), on the primary side. r The bracket that is provided with the
Setting sensitivity: 0.001 MPa Can be connected as a module to a mist separator.