Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Low Friction (Internal Resistance), End Locking: No, Cushion: Rubber cushion, Operating Pressure(MPa): 0.03 to 0.7, Specification: Built-in magnet, Port thread
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Low Friction (Internal Resistance), End Locking: No, Cushion: Rubber cushion, Operating Pressure(MPa): 0.03 to 0.7, Specification: Built-in magnet, Port thread
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Low Friction (Internal Resistance), End Locking: No, Cushion: Rubber cushion, Operating Pressure(MPa): 0.03 to 0.7, Specification: Built-in magnet, Port thread
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Low Friction (Internal Resistance), End Locking: No, Cushion: Rubber cushion, Operating Pressure(MPa): 0.03 to 0.7, Specification: Built-in magnet, Port thread
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Auto Switches: None, Lead
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Auto Switches: None, Lead
Series CJ2 miniature cylinders available in spring return, spring extend, or double acting offer stainless steel tubing and stainless steel rods. The series is available in bore sizes 6, 10, 16mm and stroke lengths from 1/2in. to 8in.. Mounting options include basic, foot, front flange, and double rear clevis. Series CJ2 is auto switch capable Standard double acting single rod, Bore sizes
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in magnet
Magnet: D (Built-in), Mounting: B (Through Hole), Bore Size: 40mm, Thread: M5x0.8 (20-25 Bore); Rc (32-100 Bore), Stroke: 25mm, Body Option: Standard, Locking Direction: B (Retracting Stroke Lock), Auto Switch: M9NV--Solid State, Gen. Purpose, 3 Wire NPN, Vertical, 0.5M, Lead Wire or Prewired Connector: M (1 m)
Magnet: D (Built-in), Mounting: B (Through Hole), Bore Size: 40mm, Thread: M5x0.8 (20-25 Bore); Rc (32-100 Bore), Stroke: 50mm, Body Option: Standard, Locking Direction: B (Retracting Stroke Lock), Auto Switch: M9NV--Solid State, Gen. Purpose, 3 Wire NPN, Vertical, 0.5M, Lead Wire or Prewired Connector: M (1 m)
Magnet: D (Built-in), Mounting: B (Through Hole), Bore Size: 40mm, Thread: M5x0.8 (20-25 Bore); Rc (32-100 Bore), Stroke: 30mm, Body Option: Standard, Locking Direction: B (Retracting Stroke Lock), Auto Switch: M9NV--Solid State, Gen. Purpose, 3 Wire NPN, Vertical, 0.5M, Lead Wire or Prewired Connector: M (1 m)
Magnet: D (Built-in), Mounting: B (Through Hole), Bore Size: 40mm, Thread: M5x0.8 (20-25 Bore); Rc (32-100 Bore), Stroke: 75mm, Body Option: Standard, Locking Direction: B (Retracting Stroke Lock), Auto Switch: M9NV--Solid State, Gen. Purpose, 3 Wire NPN, Vertical, 0.5M, Lead Wire or Prewired Connector: M (1 m)
Magnet: Built-in, Mounting: Through Hole, Bore Size: 40mm, Thread: M5x0.8 (20-25 Bore); Rc (32-100 Bore), Stroke: 30mm, Body Option: Standard, Locking Direction: Retracting Stroke Lock, Auto Switch: M9NV--Solid State, Gen. Purpose, 3 Wire NPN, Vertical, 0.5M, Lead Wire or Prewired Connector: 1 m, Number: -
Magnet: Built-in, Mounting: Through Hole, Bore Size: 40mm, Thread: M5x0.8 (20-25 Bore); Rc (32-100 Bore), Stroke: 75mm, Body Option: Standard, Locking Direction: Retracting Stroke Lock, Auto Switch: M9NV--Solid State, Gen. Purpose, 3 Wire NPN, Vertical, 0.5M, Lead Wire or Prewired Connector: 1 m, Number: -
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in magnet
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, D/ACT, F/SEAL, ACTUATOR, CJ2 ROUND BODY CYLINDER, EC, 10MM CJ2 OTHERS (COMBO), 0.22046 lb
Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.), Auto Switch Mounting Type: B (Band Mounting)
(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)