Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in magnet
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.2 to 1.0, Specification: Without magnet
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.2 to 1.0, Specification: Without magnet
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.2 to 1.0, Specification: Without magnet
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.2 to 1.0, Specification: Without magnet
Magnet: None, Mounting: Basic Style, Size: Pressure Receiving Area Equivalent to that of ø25 Type, Thread: M Threads (ø25) Rc Threads (ø32, ø40, ø50), Stroke: 15mm, Rod End: Rod End Female Thread, Locking Direction: Retracting Stroke Lock, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: D (Built-in), Mounting: B (Through Hole), Bore Size: 63mm, Thread: M5x0.8 (20-25 Bore); Rc (32-100 Bore), Stroke: 15mm, Body Option: Standard, Locking Direction: B (Retracting Stroke Lock)
Magnet: D (Built-in), Mounting: D (Clevis), Bore Size: Ø6 mm, Stroke: 15 mm, Rod End Thread: B (Without Thread)
Magnet: Built-in, Mounting: Rod Flange, Bore: 16mm, Stroke: 15mm, Head Cover: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting: Band Mounting, Cushion: Rubber
Magnet: Built-in, Mounting: Basic, Bore: 10mm, Stroke: 75mm, Head Cover: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting: Band Mounting, Cushion: Rubber Bumper
Magnet: Built-in Magnet, Series: J2W, Mounting: Basic Style, Bore Size: 16mm, Stroke: 30mm, Cushion: Rubber Bumper, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: Band Mounting
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9BW, Lead
Bearing Style: Slide Bearing, Bore Size: 40mm, Port Type: Rc, Stroke: 50mm, Z: Z, Locking Direction: Retraction Stroke Lock, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -
(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)
(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)
(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in