Wireless system configuration example 75 6.1. Flow chart for using the wireless system (Refer to Step 2) 75 6.2. System Construction Example 76 6.3.

M5 x 0.8 SYJA514-01 0.32 0.46 1.1 0.32 0.41 1.2 75 (Without subplate 45) Rc 1/8 N.C. Base mounted (with sub-plate) 0.34 0.48 1.2 0.33 0.37 1.3 N.O. SYJA524-01 SYJA712-01 SYJA722-01 SYJA714-01 SYJA714-02 0.76 0.69 0.69 0.66 0.63 0.64 0.51 0.42 0.34 0.33 0.45 0.48 2.5 2.4 2.7 2.6 2.3 2.3 0.77 0.72 0.71 0.74 0.70 0.68 0.43 0.38 0.32 0.31 0.21 0.31 2.8 2.7 2.9 3.0 2.8 2.7 N.C. N.O.

unit only (kPa) P With unit switching function (Initial value psi) D Vacuum pressure switch *3 For q, the units for metric spec. fittings are in kPa.

B' B C Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Drain cock Drain guide R, NPT, G Operating Pressure: 0.5 (MPa) Operating pressure: 0.5 (MPa) Mounting bracket Port size Model E M3 x 0.5 Depth 8 Drain piping D C B A F G H J K B' 3 8 AMC310 75 140.5 138.5 150.5

The signal has to be converted by a A/D converter for pressure display or switch output. Current Output signal is a current signal in the range of 4 to 20[mA]. The signal is transformed into a voltage signal before being converted by a A/D converter for pressure display or switch output.

Accessory (Option) Basic size (Applicable compressor kW) F With screw flange D With auto-drain Port size Symbol 2 Screw type Reciprocating type 2.2 7.5 15 22 37 55 75 04 06 14 20 30 Rc 1 2 Rc 3 4 Rc 1 1 2 Rc 2 3B flange HAW2 HAW7 HAW22/37 HAW55/75 HAW110 Caution on Design 7 22 22 Warning 1.

No.CE*-OMP0002-A 3 CEU1 SMC FG 0~50 35~85%RH 3 CEU1CE10.1mm 3 CE1-R** CE1** 3 CEU1** FG 3 DIN 3 2m/s 3 (100ms) 2 2 2 2-1 1 1 1 CEU1 4 2 2 2 2-2 2 2 2 3 3 3 3-1 1 1 1 : : 1 1 (mm) (mm) 25 25 25 25 50 50 50 50 75 75 75 75 100 100 100 100 125 125 125 125 150 150 150 150 175 175 175 175 200 200 200 200 250 250 250 250 300 300 300 300 400 400 400 400 500 500 500 500 12 12 12 12

A A B C D E F A B C D A B C D A B C D A B C D Tubing O.D. PA 1 2 1 2 3 4 1 2 3 4 5 6 1 2 3 4 1 2 3 4 1 2 3 4 1/8" 1/8" PAX 1/8" 1/8" PB 1/4" 1/4" 1/4" 1/4" 3/8" 3/8" 3/8" 3/8" 1/2" 1/2" 1/2" 1/2" 3/4" 3/4" 3/4" 3/4" 1" 1" Note) For each body class, the second and later numbers or symbols indicate reducing.

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 100mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewied Connector: -, Number: -

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 100mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: F5P--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire or Prewied Connector: 1.0m Cord Length, M8-3 Pin Connector, Number: -

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 100mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: F5P--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire or Prewied Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 100mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: F5P--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire or Prewied Connector: 5m, Number: -

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 1100mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewied Connector: 3m, Number: -

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 200mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewied Connector: -, Number: -

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 200mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: G39--Solid State, Gen. Purpose, 3 Wire NPN, Terminal, Lead Wire or Prewied Connector: -, Number: -

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 200mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: G5P--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire or Prewied Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 250mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: A53--Reed, DC Volt >5<24, LED, Lead Wire or Prewied Connector: 3m, Number: 1 pc.

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 250mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewied Connector: 3m, Number: -

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 25mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: A59W--Reed, DC Volt >5<24, 2-color Indication, 2 Wire, Lead Wire or Prewied Connector: 5m, Number: -