Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 450, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 650, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 700, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 800, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 900, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

JIS symbol Double acting Minimum Strokes for Auto Switch Mounting Stroke Long stroke (2) (mm) Max stroke (mm) Number of switches Bore size (mm) Standard stroke (1) (mm) Auto switch model 2 1 D-C7/C8 D-B5/B6 D-H7 D-G5/K5 25, 50, 75, 100, 125, 150, 200 201 to 350 20 15mm 10mm 301 to 400 25 301 to 450 32 25, 50, 75, 100, 125, 150, 200, 250, 300 20mm 15mm 1500 301 to 800 40 D-B59W 301 to 1200

1 e w r e Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com u r u t t y y q q Component Parts Description Material No. Option Standard Stainless steel Body C37 q w e r t y u i o !0 !

energy computation Stroke (mm) Example) Cylinder CDQ2B180-100DCM Load weight 10kg Piston speed 100mm/s = 0.1m/s Computation of m2 Note: 1in = 25.4mm 1N = 0.2248lbf 1kg = 2.2046lb 1J = 0.7375ft.lb Basic weight Additional weight 3.48kg 0.08kg 0.74kg Total 4.30kg CQ2B180-100DC Built-in magnet Rod end male threads Computation of E E = = 0.0715J (4.3 + 10) (0.1) 2 21 World Wide Support...

3 w e q !1 r y o e t !2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 4 Built-in magnet Without magnet Single acting u i r y o e w i e u !

Min. bending radius (mm) 75 60 48 36 24 25 13 100 15 20 30 60 75 Caution Operating temperature 20 to +60C (Water: 0 to 40C) (No freezing) 1. Applicable for general industrial water. Please consult with SMC if using other kinds of fluid. Surge pressure must be under the max. operating pressure.

2 46 M6 x 1 9 0 V 75 220 55 114 89 75 56 M6 x 1 9 50 msec Analog output 1 to 5 VDC PF2A7H--68 69(-M) 4 to 20 mADC 5 20 Analog output [mA] Analog output [V] 1 4 Min. measured flow rate value Min. measured flow rate value Max. measured flow rate value Real-time flow rate [l/min] Max. measured flow rate value Real-time flow rate [l/min] Minimum measured flow rate value [l/min] Maximum measured

: Push locking slotted style R port P/E port Pilot valve exhaust is centralized to main valve.

Seal type Nil E With Without 0 1 Metal seal Rubber seal 6. Manual override 3. Function Nil Y R Nil B Non-locking push type (tool required) Slotted locking type (tool required) Standard type (1.0W) Energy saving type (0.5W) External pilot Note) When specifying more than one option, enter symbols in alphabetical order. 7.

DXT170-75-1 Connection/Disconnection of socket with lead wire Connection Insert lead wire and crimped socket into square holes (indicated as A, B, COM) of connector. Press the socket in fully until the hook of the socket locks into the groove of the connector housing. Confirm the locked position by lightly pulling on the lead wire.

Standard Strokes Bore size [mm] Standard stroke [mm] Max. manufacturable stroke 32 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 300 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 300 45 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 300 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 400 56 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 400 63 25, 50, 75, 100, 125, 150

The acquisition of waveform will be canceled with Stop button. 75 - 5.11.3 Operation Instruction When the PLC on the master side sends the operation command, the actuator will operate. When the trigger conditions in 5.11.1 (2) are satisfied, the operation waveforms can be captured.