SMC Corporation of America
Elite Part Number Search
Search Results "CDQ2D32-100DMZ-W-M9BW"

5 w @7 !1 !7 !8 !9 @0 e #7 i !6 @5 #5 q #9 #4 !3 #2 !2 @1 !0 @2 @6 #6 #3 @8 #1 @4 o #8 !

10 High precision type CRJ MSZB A M9BW 10 Basic type CRA1 Number of auto switches CRQ2 Nil n 2 pcs. n pcs.

A B W A B W A B W 12 6.2 6.2 3.8 6.2 6.2 1.8 6.2 6.2 5.8 6.2 6.2 3.8 16 6.7 6.7 3.3 6.7 6.7 1.3 6.7 6.7 5.3 6.7 6.7 3.3 20 7.5 10 7.5 10 7.5 10 2 7.5 10 25 8 12 8 12 8 12 8 12 Auto Switch Mounting Height U [mm] Auto switch model Bore size D-M9V, D-M9WV, D-M9AV U 12 19.5 16 21 20 23 25 24.5 W A B A Operating Range [mm] Auto switch model Applicable bore size 12 16 20 25 D-M9m(V)/M9mW

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions.á Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improvingáease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *:á 12, 16, 20, 25

1 u t q w e y !2 i r #3 !4 !0 !9 !8 !5 !

9 w !4 CY3B10, 15 !4 !8 !7 !6 !5 !0 i o q u y t r !2 w !1 The above drawing is 15. (3 magnets are used in 10.) CY3B20 to 40 !3 !4 !1 !8 !6 !5 !7 !0 i q o u t y r e w !2 CY3B50, 63 !4 !8 !6 !5 !0 !7 i o q u y t !3 r !2 w !1 Component Parts Replacement Parts/Seal Kit Bore size (mm) 6 10 15 20 25 32 40 50 63 Kit no.

Stroke Against Lateral Load D 17 24 27 29 0.7 W W W 500 82 103 116 127 0.3 Bushing (Bearing) fR U 62 79 89 97 0.5 Lateral load applied to rod end (fR) N 100 52 66 75 81 0.7 50 33 43 49 53 0.3 10 23 31 36 39 T 0.5 REC40 REC32 REC25 REC20 5 18 25 29 31 0.7 2 Rod side flange style: F Head side flange style: G 182 167 148 118 Foot style: L 0.3 1 L 140 128 114 90 0.5 0.5 W W W F REA 117 108 95

Stroke Against Lateral Load D 17 24 27 29 0.7 W W W 500 82 103 116 127 0.3 Bushing (Bearing) fR U 62 79 89 97 0.5 Lateral load applied to rod end (fR) N 100 52 66 75 81 0.7 50 33 43 49 53 0.3 10 23 31 36 39 T 0.5 REC40 REC32 REC25 REC20 5 18 25 29 31 0.7 2 Rod side flange style: F Head side flange style: G 182 167 148 118 Foot style: L 0.3 1 L 140 128 114 90 0.5 0.5 W W W F REA 117 108 95

Work W Work W Work W Work W Bracket Cylinder goes up Cylinder goes down Lever basic position Lever locked Lock released With cancel cap With lever detection switch RSQ When the lever stands erect (when the energy is absorbed), the switch turns on a signal that determines the pallet has reached the stop position. (For details of lever detection switch, refer to page 595.)

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Without built-in magnet, Support

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket