Calculating motor speed conversion example using an actuator with a 20mm lead and 500[mm/sec] speed.
D type DIN connector with 9.4 mm pitch between terminals is not interchangeable. To distinguish from the D type DIN connector, N is listed at the end of voltage symbol.
Applicable bore (mm) A D L MM N R W B C H d Applicable bore (mm) Part no.
Applicable bore (mm) A D L MM N R W B C H d Applicable bore (mm) Part no.
AS-FG AS301FS, AS311FS AS401FS, AS411FS AS-FP Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa AS-FM 10, 11, 12 10, 11, 12 12, 13, 16 12, 13, 16 1500 1000 10, 11 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 08, 09 AS-D 06, 07 1000 AS-T 500 ASP 500 ASN 0 0 5 0 10 5 0 10 AQ Number of needle rotations Number of needle rotations ASV Note) The numbers above the flow rate characteristic curves
Wiring Electrical entry Auto switch type Electrical entry from inside 3-wire D-F9P B Solid state switch D-F9 In-line 2-wire D-F9B 3-wire D-F9NW,D-F9PW In-line 2 color indication solid state switch D-F9 W 2-wire D-F9BW 3-wire D-F9NWV,D-F9PWV Perpendicular B 2-wire D-F9BWV Install auto switch as shown in figure below.
***D-A7l, D-A8l, D-F7l and D-J7l are available as option. 4.3-2 Heavy Duty Stopper Cylinder Series RSH Models Applicable auto switch Construction Action Bore size (mm) Reed switch Solid state switch Rod end configuration Mounting Fixed mounting height D-Y5 D-Y6 D-Y7 Double with spring Single/spring extend Flange 20, 32 50, 63 80 D-Z7 D-Z8 Lever with built-in shock absorber MK/MK2 Specifications
Reuse AS-FE Nominal thread size Chamfered dimension D Min.
AS-FG AS-FG AS301FSG, AS311FSG AS401FSG, AS411FSG AS-FP Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa AS-FM 10, 11, 12 10, 11, 12 12, 13, 16 12, 13, 16 1500 1000 10, 11 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 08, 09 AS-D 06, 07 1000 AS-T 500 ASP 500 ASN 0 0 5 0 10 5 0 10 AQ Number of needle rotations Number of needle rotations ASV Note) The numbers above the flow rate characteristic
5 D-side end plate assembly Manifold block assembly !6 D-side end plate assembly part no. !7 Manifold block assembly part no.
Meter-out M5 type U10/32 port AS3200-02-D Meter-out M5 type U10/32 port AS2210-01-D AS3210-02-D Component Parts No.
width across flats) AS-D AS-T ASP ASN AQ ASV AK Metric Size Inch Size VCHC Model d T Weight (g) H D1 D2 L1 L2 L3 L5 (1) A (2) Model d T Weight (g) H D1 D2 L1 L2 L3 L5 (1) A (2) D3 L4 Max.
Description Material AS800 AS900 6 7 8 O-ring O-ring Spring NBR NBR Stainless steel KA00069 KA00460 14115 KA00072 KA00462 14124 ASV AK VCHC Dimensions: AS420/500/600 Dimensions: AS800/900 ASS ASR ASQ 2 x Port size 2 x Port size L3 L2 L1 D Dimensions L1 L2 D Min. L3 (1) Model Port size Max.
OUT() DC(-) DC(+) PSE57--28 420 mA N.C. 500 (24 V ) 100 (12 V ) OUT() DC(-) -13No.PS-OMS0004CN-D (A/D ) () 20 2030 -14No.PS-OMS0004CN-D PSE570 PSE573 PSE574 01MPa -100100 kPa 0500 kPa 3.0MPa 600 kPa 1.5MPa oC) oC) (25 ) 2F.S.(050 3F.S.(050 oC) oC) 3F.S.(-1060 4F.S.(-1060 PSE57PSE57--28 DC1224 V1010% 10 mA 420 mA 15 V 1 k 500 (24 V ) 100 (12 V ) (25 oC) 1.0F.S. 0.5F.S. oC)
D-F9 D-F9 W B W 20 (22) A D-A9 V D-F9 V D-F9 WV W B Dimension inside ( ) is for model D-A9 V.
D A B Grommet with membrane Power cable outlet (17) Dimensions (mm) A 230 B C D Circuit breaker Model 32 B D IDFA4E, 6E, 8E, 11E IDFA15E1 67 179 43 258 77 158 C E A IDFA22E to 75E Power cable outlet (17) (Wire diameter 9 to 11) F (mm) Dimensions E D C B A F Model Signal cable outlet (Wire diameter 17) Grommet with membrane IDFA22E IDFA37E IDFA55E IDFA75E 59 125 40 25 46 39 60 Terminal block
l Cross section C-C #i .. :: fl ffi -i+-sLJ rr Model D f G, I K L !,!
D-A5/A6, D-A59W Tie rod mounting D-G3/K3 Band mounting Solid state swich D-F5/J5, D-F5NT, D-F5W/J59W, D-F5BA, D-F5F Tie rod mounting 1.10-1 Air Cylinder/Standard Series CS1 Lube, Non-lube: 125, 140, 160, 180, 200, 250, 300 Air-hydro: 125, 140, 160 How to Order CS1 L 300 160 JR Rod boot/Cushion Rod boot Mounting J K N R H Nylon tarpaulin Heat resistant tarpaulin No cushion With cushion on
Reuse AS-FE Nominal thread size Chamfered dimension D Min.
mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (No inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting 12 4.7 k Contact input signal 2 Circuit diagram 4 1 k 11 Run/stop signal input Contact input signal