ZR1D1 D2 D3 10.2 SMC PRESURRE SWITCH RESET SET Attachment D Digital pressure switch Suction filter 71.3 (73.3 for D2, D3 types) 81 SMC 61 PV PD Filter block D 78.8 3 Note) 1 Dimensions for mounting bracket A 2 Dimensions for mounting spacer A Bracket A part no. : P3270153 (Standard accessory) Spacer A part no. : P3270156 13-3-19 19 Series ZR Suction Filter: ZR1-FX Specifications ZR1-FX
Acceleration/deceleration time (ms) = {3000 (r/min) 60 (S) } 8 (mm) 1000 3000 (mm/s2) 133 (ms) Speed at a rated motor rotation of 3000rpm Accel/decel time (ms) = {Rated Rotation Speed (r/min) 60 (S) } Screw Lead (mm) 1000 * Acceleration/deceleration speed (mm/s2) *Acceleration speed is measured in ms, so this must be calculated as (s) 1000 47 - 5.6.4 Move distance Configuration and Operation
(Example: When the value can be displayed down to 0.001 MPa for the product for 0 to 1 Mpa, the resolution is 1/1000) Display resolving power Displayed pressure value can be adjusted within the range of 5%R.D. (5% of displayed value).
200, 250, 300 63 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100 MGGL Ball bushing 80 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200 100 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1300 Intermediate strokes and short strokes other than the above are produced upon receipt of order.
Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-17 Connection of RS-232C HRS090 Series 3.3Installation 3-27 HRX-OMT002 Chapter 3 Transport and Setting Up 3.4 Piping Piping port size Connect piping firmly.
To find the stroke time (t), follow arrow from your stroke length ("L") to the solid line representing the load ratio (d%) for the application then up to the stroke time (t). To find the ending cylinder speed (u), follow arrow from your stroke length ("L") to the dotted line representing the load ratio (d%) then down to the ending cylinder speed (u).
VAC for 1 min. between external terminal and case Withstand voltage Resistance 50 M (500 VDC) between external terminal and case Insulation resistance 10 to 500 Hz at whichever is smaller: 1.5 mm amplitude or 98 m/s2 acceleration Vibration resistance 490 m/s2 in X, Y, Z directions 3 times each Impact resistance 1000 Vp-p, Pulse width 1 s, Rise time 1 ns Noise resistance 200 g 240 g Weight
value (upper limit of window comparator) 1025 0x0401 0 R/W U16 3400 Y (580 ~ 5200) ISE71: 0x02E2 ~ 0x1450 (738 ~ 5200) Setting range ISE70: 0x03E8 ~ 0x0CEE WH2 (Window comparator hysteresis) Setting of OUT2 hysteresis (window comparator hysteresis) U16 1400 Y 1026 0x0402 0 R/W (1000 ~ 3310) ISE71: 0x03E8 ~ 0x0C9E (1000 ~ 3231) Setting of OUT2 delay time at ON 0.01 s increment 1027 0x0403
(example: If the Pressure switch with output impedance of 1k is connected to the A/D converter to detect the analogue output of 5V, the detected voltage by the A/D converter becomes 5(V) 1(M)/(1(k) + 1(M)) 4.995(V), and there is an error of approximate 0.005 V). Output impedance Output type The operation type of the switch output.
1500 200 400 600 800 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] AR30(K)-B Rc3/8 AR40(K)-B Rc1/2 AR40(K)-06-B Rc3/4 0.6 0.6 0.6 0.5 0.5 0.5 Outlet pressure [MPa] Outlet pressure [MPa] Outlet pressure [MPa] 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0 00 0 0 1000 2000 3000 4000 5000 0 1000 2000 3000 500 1000 1500 Flow rate [L/min (ANR)] Flow rate [L/min (ANR
PF3A702H AC40#-D Y400-D Y400T-D E400-#04-D : For more information about the options, refer to our website (URL https://www.smcworld.com). 4 Snap shot function The current flow rate value can be stored to the switch output ON/OFF set point.
PF3A802H AC40#-D Y400-D Y400T-D E400-#04-D 4 : For more information about the options, refer to our website (URL https://www.smcworld.com).
Solid state switch Model D-F8 Series Variations Bore size (mm) Rod end configuration Stroke (mm) Clean room series 4 6 8 10 15 20 Action Series Auto switch Double acting Male thread Without thread Nil 4 Single acting (spring return) Double acting 6 Single acting (spring return) CUJ Solid state switch D-F8 D-F9 Female thread Double acting 8 Male thread Single acting (spring return) Double
D-SMC, P-63 (M) 2nd printing September 1996. D-SMC, P-59(YG) March 1997. 29(YG) Printed in Japan.
Ratio of discharge rate against fresh water (%) PAX PB 50 0 1 10 100 1000 Viscosity (mPas) Caution Viscosities up to 1000 mPas can be used.
How to Order AL800 AL 23 80 12 0 R AL900 Semi-standard R Flow direction: Right Left Body size Port size Semi-standard Lubricator 1 1S-1 1S-2 2 3 6 8 1000 cm3 tank 1000 cm3 tank with switch (Bottom limit ON) 1000 cm3 tank with switch (Bottom limit OFF) Metal bowl With drain cock Nylon bowl (Including sight dome) Metal bowl with level gauge Symbol 12 14 20 4 1 1 1 2 2 1 80 90 1 2 2 1 Thread
D-F7BAVL Auto switch model D-H7 D-H7C D-H7W D-H7BAL D-H7NF D-C7 D-C80 D-C73C D-C80C D-A7 D-A80 D-A79W Bore size (mm) A 2.5 3 B 2.5 3 A 1.5 2 B 1.5 2 A 3 3.5 B 3 3.5 A 3.5 4 B 3.5 4 A 0.5 1 B 0.5 1 10 16 Auto Switch Mounting Height D-A7H/A80H D-F7/J79 D-F7W/J79W D-F7BAL/F79F D-C7/C80 D-H7/H7W D-H7NF D-H7BAL Auto switch model D-F7V D-F7WV D-F7BAVL D-C73C D-C80C D-H7C D-A7 D-A80 D-A73C D-A80C
As a rule, it should be turned about 90 past the position at which tightening can be felt. 456 Cylinder with Turntable Series MGT Minimum Stroke for Mounting Operating Range (mm) (mm) Auto switch model Bore size No. of auto switches 100 80 63 Auto switch model 63 80 100 D-A9/A9V D-A9 D-A9V D-M9 D-M9V D-Z7 D-Z80 D-Y59 D-Y7P D-M9W D-M9WV D-Y69 D-Y7PV D-Y7W D-Y7WV 11 10.5 10.5 D-M9/M9V D-M9W
Contact SMC when there is a problem of switchs ON/OFF positions (hysteresis). -7No.D-S-OMZ0004 Model Indication and How to Order D-M7BA Lead wire length and termination 2-wire Symbol Specification L 3000 mm (Half strip) Z 5000 mm (Half strip) SAPC 500 mm (M8 3-pin pre-wire) SBPC 500 mm (M8 4-pin pre-wire) SDPC 500 mm (M12 4-pin pre-wire) MAPC 1000 mm (M8 3-pin pre-wire) MBPC 1000 mm (M8 4