In the graph, find where the lines representing a load weight of 40 kg and an eccentric distance of 80 mm intersect.
Multistage Ejector RoHS Only for the models with a valve or pressure switch The ZL1 with an AC voltage valve is not compliant.
Maintain a minimum cylinder separation of 40 mm. 3. Pay attention to the length of time that a switch is on at an intermediate stroke position. When an auto switch is placed at an intermediate position of the stroke and a load connected to the auto switch is driven at the time the slide table passes, the auto switch will operate.
40 22 40 Y21-02 1/4 10 29 19 Y24-02 1/4 40 40 22 40 Y31-01 1/8 11 33 19 Y34-02 1/8 49 43 28 48 Y31-02 1/4 11 33 19 Y44-02 1/4 60 48 36 54 Y41-02 1/4 14 39 24 Y44-03 3/8 60 48 36 54 Y41-03 3/8 14 39 24 Y54-03 3/8 72 62 40 62 Y51-02 1/4 14 24 41 Y54-04 1/2 72 62 40 62 Y52-03 3/8 14 24 41 Y61-03 3/8 15 30 50.5 Y61-04 1/2 15 30 50.5 Courtesy of Steven Engineering, Inc. !
(Switch spacer and auto switch mounting bracket) Cylinder series Bore size 40 50 63 MGZ BMP1-032 BMP1-032 BMP1-032 Note) When tightening an auto switch mounting screw, use a watchmakers screwdriver with a grip diameter of 5 to 6 mm.
Install an emergency stop circuit. Install an emergency stop outside of the enclosure so that the system operation can be stopped immediately and the power supply disconnected. 4.
40 to +80C 25 to +60C 40 to +80C Cable 25 to +60C 40 to +80C 25 to +60C 40 to +80C Min. bending radius (Fixed) 40 mm 21.7 mm 40 mm 21.7 mm Protection class IP67 (Only with screw tightened) Allowable repeated insertion/withdrawal 200 Material of knurl Brass (Nickel plating) Zinc die-cast (Nickel plating) Brass (Nickel plating) Zinc die-cast (Nickel plating) Contact (Surface treatment) Phosphor
In such a case, carry out an adsorption test for confirmation. The vacuum pressure when using an ejector is approximately 60 kPa as a guide. The theoretical lifting force of a pad can be found by calculation or from the theoretical lifting force table.
35 190 190 190 190 190 190 190 10 10 10 10 10 10 10 10 10 10 10 10 10 10 90 80 65 50 45 40 35 60 50 50 40 40 30 20 17 23 27 33 37 44 57 36 50 66 68 78 91 115 40 54 60 72 82 95 19 40 54 60 72 82 95 19 21 27 31 37 41 48 61 21 27 31 37 41 48 61 10 20 30 50 70 100 200 Operating angle m: Value of the operating range Lm of a single auto switch converted to an axial rotation angle.
Example: When the IDFA100F-40 is provided with options C or R or V, the model number will be the IDFA100F-40-CRV. 98 A Refrigerated Air Dryer IDFA100F/125F/150F Series Standard Specifications For use in Asia and Oceania IDFA100F-38 IDFA125F-38 IDFA150F-38 For use in Europe Model Specifications IDFA100F-40 IDFA125F-40 IDFA150F-40 Fluid Inlet air temperature Inlet air pressure Compressed air
/ Complex exhaust) 40 40 100 Vacuum pressure [kPa] 30 30 80 Air consumption 60 20 20 40 High-noise reduction silencer exhaust 10 10 20 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0 0 0 10 20 30 40 50 60 Supply pressure [MPa] Suction flow [L/min (ANR)] 19 Vacuum Unit ZK2mA Series The flow rate characteristics correspond to the standard supply pressure.
(EXH port) 40 2333 Series VFM300 Series VFM300 Push button (Mushroom) VFM350-02-30R/B/G/Y O.T. T.T. P.T. Panel mounting hole 40 1.5 29.5 1.5 Max. 6 3 18.5 M5 x 0.8 (Pilot exhaust port) (141.7) PE EXH.1 SUP.
. ** J, K, T and Y are made to order. *** When an auto switch is mounted to the rotary actuator, only shaft types W and J are available. t Rotating angle * F: Except size 40 y Vane type i Auto switch !
V3 L 1 H 2 4 10 40 Connections Temperature range NPT 1/4 inch 40 to 140F (40 to 60C) (No freezing) 25% to 75% of the scale: 2%F.S.
10 L/min 0.5 to 10.5 L/min 5 V 20 mA 90% 10% 80% 20% 70% 30% 60% 40% 40% 60% 0.1 to 6 L/min 0.3 to 6.3 L/min 5 V 20 mA 30% 70% PF2M710 92% 8% 0.3 to 25 L/min 1.3 to 26.3 L/min 5 V 20 mA 90% 10% 80% 20% 70% 30% 60% 40% 40% 60% 0.3 to 15 L/min 0.8 to 15.8 L/min 5 V 20 mA 30% 70% PF2M725 92% 8% 0.5 to 50 L/min 2.5 to 52.5 L/min 5 V 20 mA 90% 10% 80% 20% 70% 30% 60% 40% 40% 60% 0.5 to 30 L/min
, making it possible to hold a cylinder intermediate stopping position for an extended time.
As a guide, an acceptable tightening level is reached by tightening the screw an additional 90 degrees (1/4 turn) from the point at which the screw is snug. (Refer to Figure 3.)
IZF21/31 IZF10/IZF10R Technical Data With automatic cleaning unit IZF21-m-mmSm IZF31-m-mmSm 64 (144) 20.5 (40) 64 (40) (104) 20.5 153 113.4 (195) (155) With adjustable louver IZF21-m-mmWm IZF31-m-mmWm (60) (144) 14 (40) 127 (60) (104) 14 (40) 89 127 89 (195) (155) With filter IZF21-m-mmmU IZF31-m-mmmU (144) (45) 134 5 (40) (45) (104) 5 (40) 95.5 126 87 (195) (155) 18 IZF21/31 Series Dimensions
30 55 65 70 GA 16 16 16 16 51 61 109 159 KA NA 2 2 2 2 2 4 4 4 N 4 4 4 4 6 6 6 8 HA 40 40 40 50 30 70 70 70 G 16 16 16 16 21 26 39 19 H 40 40 40 50 30 35 35 35 NN 2 2 2 2 3 4 5 7 I 10 10 10 10 15 40 55 68 J 40 40 40 50 60 85 118 155 K 29 39 49 59 69 94 119 144 Z 75 75 75 85 100 150 198 248 M 76 76 76 86 101 151 199 249 ZZ 87 87 87 97 112 162 210 260 Note) Refer to "Dimensions" of MXS 16
Install an air filter. Install an air filter upstream near the valve. A filtration degree of 5m or less should be selected. 3. Install an aftercooler, air dryer or drain catch before the filter and take appropriate measures. Compressed air that contains excessive foreign material may cause malfunction of valves and other pneumatic equipment.