6 p. 31 3 30 m ZK2 SC3 4 A Body gasket1 (10 pcs. per set) Construction !1 p. 31 Applicable nozzle size ZK2 BG5 A 4 For nozzle size 07, 10 6 For nozzle size 12, 15 1 Applicable type Release lever (10 pcs. per set) Construction !
Return port 0.02 0.02 2 2 0.00 0.00 0 2 4 6 8 10 12 14 16 0 2 4 6 8 10 12 14 16 Circulating fluid flow rate [L/min] Circulating fluid flow rate [L/min] Option (-T): High Pressure Pump Mounted HRSE -A-10-T 012 018 012 018 024 Option (-T): High Pressure Pump Mounted HRSE -A-20/23-T 0.3 0.3 Circulating fluid pressure [MPa] Circulating fluid pressure [MPa] Pump head [m] Pump head [m] 0.2 0.2
Pressure [MPa] 0.4 40 0.3 30 Usable flow rate range 0.2 20 Circulating fluid return 0.1 10 0 0 0 10 20 30 40 50 60 70 80 90 100 110 120 Circulating fluid flow [L/min] Fig. 8-9 Pump capacity(HRL100-A-20 CH1) 8.5.2 HRL200A20 CH1 0.6 60 0.5 50 Circulating fluid outlet Lifting head [m] Pressure [MPa] 0.4 40 0.3 30 Usable flow rate range 0.2 20 Circulating fluid return 0.1 10 0 0 0 10 20 30 40
Manual Override How to Use L/M Plug Connector Caution Warning Attaching and detaching connectors Without an electric signal for the solenoid valve the manual override is used for switching the main valve. Locking type (Tool required) is available as an option.
10 12 16 20 5 6.5 8 10 14 15 18 20 7 10 12 14 4 4 5 5 5 5 8 10 * Refer to P.2.3-18 for detail of the rod end nut and mounting brackets.
weight: m (kg) 63 50 50 40 30 50 40 30 CL1 40 20 20 MLGC 10 10 CNG 5 4 3 5 4 3 MNB 2 2 CNA 1 100 200 300 400 500 1000 1 100 200 300 400 500 1000 CNS Maximum speed: V (mm/s) Maximum speed: V (mm/s) CLS Graph (6) Graph (3) 0.4 MPa P < 0.5 MPa 0.4 MPa P < 0.5 MPa 1000 1000 CLQ 100 500 400 300 500 400 300 80 MLGP 100 63 200 200 50 40 80 RLQ Load weight: m (kg) Load weight: m (kg) 100 100 63
0.5 MPa P 1000 1000 100 80 500 400 300 500 400 300 63 100 100 80 50 40 80 200 200 63 63 100 100 Load weight: m (kg) Load weight: m (kg) 50 50 50 40 30 50 40 30 40 40 20 20 10 10 5 4 3 5 4 3 2 2 1 100 200 300 400 500 1000 1 100 200 300 400 500 1000 Maximum speed: V (mm/s) Maximum speed: V (mm/s) 9-7-7 8 Cylinder with Lock Double Acting, Single Rod Series CNA 40, 50, 63, 80, 100 How to
Select compatible materials of construction for the gas Vacuum to 250 psig (1.7 MPa) 500 psig (3.4 MPa) 1000 psig (6.9 MPa) 14 to 160F (10 to 71C) (No freezing) 2.8 2 x 10-11 Pam3/sec 2 x 10-10 Pam3/sec 1) 4 x 10-9 Pam3/sec 1) Ra max 15 in. (0.4 m) Option: 10in.(0.25 m), 7in.(0.18 m), 5in.(0.13 m) Face seal, Tube weld 80 to 100 psig (0.55 to 0.7 MPa) 10-32 UNF thread Side Bottom mount 0.76
With cushion on head end 05 Exension cable CE1-R Cable length 05 10 15 20 Suffix 5 m Nil Extension cable 10 m C Extension cable & connector 15 m 20 m Applicable Auto Switches/Refer to pages 941 to 1067 for further information on auto switches.
B Counter bore depth C 2-P (Piping port) T Y HP L 0 -0.1 4-J x E TC X F WP D GW QW PW 7 GP 4-LD 2 x 4-MM Thread depth M Switch rail W K Plug HS Q + Stroke G G HR CR Z + Stroke CY3R25, 32, 40 CY3R15, 20 (mm) Model CY3R15 CY3R20 CY3R25 CY3R32 CY3R40 J x E M5 x 0.8 x 7 M6 x 1 x 8 M6 x 1 x 8 M8 x 1.25 x 10 M8 x 1.25 x 10 A 10.5 9 8.5 10.5 10 HC 31 38 43 54 66 HP 17 24 23.5 29 36 HR 30 36 41 51
A Bore size (mm) 32 40 50 63 80 100 125 H 0.5 0 0.1 C DH7 FH11 L M N P 15 32.5 10.5 22 10 14 30 6.6 45 10.5 5.5 5 38 12 25 12 16 18 35 6.6 55 11 5.5 5 51 15 21 20 46.5 27 16 40 9 65 15 6.5 5 56.5 15 32 16 21 23 45 9 75 15 6.5 5 70 27 72 18 36 20 25 45 11 95 18 10 5 89 18 41 20 25 30 55 11 115 18 10 5 40 110 25 50 30 37 60 13.5 140 20 10 7 100 Black color 81 Series CP96/C96 Dimensions
Refer to LECSS2-T Operation Manual,section 3.5 for input/output signal details. -10- 3.3.2 Source Sink I/O interfaces Connection example An example wiring diagram for Sink I/O is shown below Driver Servo amplifier () CN8 (Note 16) Short-circuit connector (Packed with the servo amplifier) 10 m or less driver) (Note 12) CN3 10 m or less 24 V DC (Note 10) 3 DOCOM (Note 15) Main circuit power
0.35 MPa H 0.50 MPa Nil None V Yes * (With 2 mounting screws) q Electrical entry L plug connector M plug connector L LO M MO L: With lead wire (300 mm) LO: Without connector M: With lead wire (300 mm) MO: Without connector A 1-stage check valve is required for specifications with pressure switches with an energy saving function. c How to Order Silencer Assembly (With sound absorbing material
Use a fitting/tube (M-3AU-3 fitting and TIU01tube are recommended), extend the piping to the location where there is no water, dust, etc. 12. When using in an enclosed environment, like an inspection box, etc., make sure to install a fan or other such device to prevent from overheating. Caution 1. Install an air filter near this product on the supply side.
Operating Fluid and Ambient Temperature Tightness of Valve (Leakage Rate) Seal material Leakage rate Operating fluid temperature (C) Solenoid valve option (symbol) Ambient temperature (C) Note) Non-leak, Medium vacuum 106 Pam3/sec or less Power source Air Nil, G V, M 10 Note) to 60 10 Note) to 40 1 cm3/min or less NBR, FKM 10 Note) to 80 10 Note) to 60 20 to 60 20 to 40 AC DC Note) Value
M plug connector: VZS2150-M(Z)-01 DIN terminal: VZS2150-D(Z)-01 Applicable cable O.D.: 3.5 to 7 MAX.10 96.5 300 72.5 (Lead wire length) With light/surge voltage suppressor With light/surge voltage suppressor Pg7 79 71.5 Other dimensions are the same as the grommet type.
Install an air filter. Install an air filter on the inlet side in close proximity with the regulator. Select a type with 5 m or smaller filtration. 2. Install an after cooler, air dryer or mist separator (drain catch) to remove drainage. Compressed air containing excessive drainage may cause malfunction of the regulator, pressure switch or other pneumatic equipment. 3.
Install an air filter. Install an air filter on the inlet side in close proximity with the regulator. Select a type with 5 m or smaller filtration. 2. Install an after cooler, air dryer or mist separator (drain catch) to remove drainage. Compressed air containing excessive drainage may cause malfunction of the regulator, pressure switch or other pneumatic equipment. 3.
IO-Link device) 12 to 24 VDC 10% with 10% voltage ripple or less Power supply voltage When used as an IO-Link device 18 to 30 VDC, including ripple (p-p) 10% Current consumption 35 mA or less Protection Polarity protection Power supply Accuracy Display accuracy 2% F .S. 1 digit (Ambient temperature of 25 3C) Repeatability 0.2% F .S. 1 digit Temperature characteristics 2% F .S. (25C standard