Bore size (mm) C1 H1 L1 X 32 40 50 20.5 23.5 M14 x 1.5 28.5 20.5 23.5 M14 x 1.5 28.5 26 28.5 M18 x 1.5 33.5 Basic Style A B C D E F H I J K L M N Bore size (mm) 32 40 50 Stroke range (mm) 20 to 100 44 37 13 16 45 18.5 M8 x 1.25 60 4.5 14 7 34 5.5 20 to 100 51 44 13 16 52 20 M8 x 1.25 69 5 14 7 40 5.5 30 to 100 57.5 49.5 15 20 64 28.5 M10 x 1.5 86 7 17 8 50 6.6 OB P Q RB S U Z Bore size (
When re assembling, tighten the cover through an extra 2--3+ from the 155,9 OUT 31 ,2 187,0 93,5 :,24.7 original assembled position. 20 63 140,2 IN 28,0 84,1 112.1 168.2 .
Enable Generates an error. 1 Unit Disable Does not generate an error. -10..10 V -5..5 V -20..20 mA 0..10 V 2 Analogue input range Sets the analogue input device range. Selects the analogue input range. -10..10 V Channel 0..5 V 1..5 V 0..20 mA 4..20 mA Offset binary Offset binary.
The pressure sensors do not have an explosion proof rating. Never use pressure sensors in the presence of inflammable or explosive gases. 20 Series PSE Specific Product Precautions 2 Be sure to read before handling. Refer to pages 17 through 19 for general safety instructions and common precautions, and to pages 20 through 22 for specific product precautions.
H G I J K L A B C D E F M R +0.058 0 -0.1 -0.2 -0.1 -0.2 -0.1 -0.3 -0.1 -0.3 AD-FI-20 AD-FI-25 AD-FI-32 9 9 16 16 +0.027 0 +0.027 0 +0.027 0 +0.027 0 36 38 55 55 16 18 22 22 9 9 12 15 20 25 32 40 10 10 15.5 15.5 20 20 24 24 14 14 20 20 M8 x 1.25 M10 x 1.25 M14 x 1.5 M16 x 1.5 20 25 32 40 46 46 56 64 28 30 40 43 60 60 80 88 22 22 30 30 16 16 16 24 10 10 12 16 30 30 36 44 M4 10 10 13 13 10
Material Polyolefin (Equivalent to UL-94 standard V-0) 0 20 0 20 40 60 Note) The color of all inner tubing is black.
Examination of Load Rate an A 0.25 B 0.375 C 0.25 D 0.073 an 0.948 Decision an1 ML2B32 is selected 20 . With Guide 1. Operating Conditions Model : ML2B25 Load : 30N Speed , Va : 350mm/s Mounting Direction : upon wall W The weight of table is considered as 0 in this case. However, during actual application, it should be taken into consideration. 2.
0 n r Ro 18 tio ta or tio ta t f n r Ro fla an le ge ng of si +10 0 0 Ro 19 tat or io t f n r fla an gle ge sin of With external stopper For 90 For 180 Single flat Single flat 5 A A e ng ng ng le le ra ad ad t ju ju en st st m m m st en en ju t r t r ad an an gle ge ge An 5 5 B port A port B port A port 90 A 5 ng ge le an ad t r ju en st m 180 Note) The drawings show the rotation range
Do not use in an atmosphere of corrosive gases, chemicals, sea water, water or water vapor or in an environment where such substances may adhere. 2. Provide shading in an environment where the product is exposed to the sunlight. 3. Do not use in an environment where a heat source is at a close distance. 4. Do not use in an environment where static electricity is a problem.
(Blanking plate) Rc G NPT NPTF Nil F N T Common exhaust Valve stations VV317-02-051-02 A port size (Base piping) 1/4 02 2 stations Symbol Passage Porting specifications A Side R P Common Common 3 Side Individual Common 20 20 stations Symbol Max. 20 stations 1 VV317-02-053-02 Individual exhaust Manifold Specifications Manifold type Max. number of stations Applicable solenoid valve B mount
OO PP QQ RR SS TT UU VV Model Applicable gasket ML1C25 ML1C32 ML1C40 10 14 37 24 8 27 20 8 C11.2 16.5 18 46 30 12 32 22 8 C11.2 17 23.5 12.5 10 53 40 34 26 C14 A B C D E F G H I J K L M N O P Q R S T U V W Y Z Model ML1C25 ML1C32 ML1C40 274 260 137 140 88 108 87 85.5 60 74 97 100 42.5 26 34 206 28 24 5.6 9 5.5 M5 x 0.8 8.5 M6 x 1 9.5 11 M8 x 1.25 322 306 161 160 108 131 101 99.5 64 92 118
Center of gravity (ZXP7-PFL1-ZPB25JN-X1) Y Y Z X (Unit: mm) Z Center of gravity X Y Z 0.64 0.57 13.96 X -11No. TQ1230001-OM107 5.3. Suction cup with adapter *It is shown here for representative model only. See the suction cup catalog for the other models.
Center of gravity *MHM-25D-X7400A-DTP Z TCP Y X Flange mounting surface MHM-25D-X7400A-DTP MHM-25D-X7400A-HC10DT MHM-25D-X7400A-HC10 X Y Z X Y Z X Y Z Center of gravity(mm) 2.4 0.0 42.6 1.0 -0.4 57.1 1.0 -0.4 57.9 X Y Z X Y Z X Y Z Tool Center Point(TCP) 0 0 114 0 0 138 0 0 140 17 - 4.
Applicable bore size (mm) 20 25 32, 40 50, 63 80 100 t Applicable bore size (mm) Applicable snap ring 20 25 32, 40 50, 63 80 100 Part no.
to 760 10 to 300 701800 Note2) Stroke 30 to 930 20 to 620 10 to 300 801900 Speed range [mm/s] 30 to 780 20 to 520 10 to 250 9011000 30 to 660 20 to 440 10 to 220 10011100 Actuator specification 30 to 570 20 to 380 10 to 190 11011200 20 to 500 30 to 500 10 to 250 1000 Driver type LECPA Note2) Stroke 30 to 500 20 to 440 10 to 220 Speed 10011100 range [mm/s] 30 to 500 20 to 380 10 to 190 11011200
Series ZM 13-14-20 4.
Cautions for use in an interlock circuit When an auto switch is used for an interlock signal requiring high reliability, devise a double interlock system to avoid trouble by providing a mechanical protection function, or by also using another switch (sensor) together with the auto switch. Also perform periodic maintenance inspections and confirm proper operation. 9.
Cautions for use in an interlock circuit When an auto switch is used for an interlock signal requiring high reliability, devise a double interlock system to avoid trouble by providing a mechanical protection function, or by also using another switch (sensor) together with the auto switch. Also perform periodic maintenance inspections and confirm proper operation. 9.
Cautions for use in an interlock circuit When an auto switch is used for an interlock signal requiring high reliability, devise a double interlock system to avoid trouble by providing a mechanical protection function, or by also using another switch (sensor) together with the auto switch. Also perform periodic maintenance inspections and confirm proper operation. 9.
, 0.7MPa 0.6MPa, 0.7MPa 20 20 MHZ2/Standard 10 10 0 10 20 30 40 50 60 0 10 20 30 40 50 60 Gripping point L mm Gripping point L mm H H MHZ 2-20 MHZ 2-20 Gripping point 100 L 80 Pressure 0.2MPa 80 Pressure 0.2MPa Overhang H mm Overhang H mm 60 MHZJ2/With dust cover 60 0.6MPa 0.3MPa 0.7MPa 40 0.4MPa 0.5MPa 0.3MPa 0.4MPa 0.5MPa 0.6MPa 0.7MPa 40 20 20 0 20 40 60 80 0 20 40 60 80 100 Gripping point