Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: C [1 NPN Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -
Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: ø1/4 One-touch Fitting, Piping Entry Direction: Bottom Side, Output Specification: C [1 NPN Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -
Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: Rc1/8, Piping Entry Direction: Straight, Output Specification: C [1 NPN Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -
Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: C [1 NPN Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -
Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: ø1/4 One-touch Fitting, Piping Entry Direction: Bottom Side, Output Specification: C [1 NPN Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: ø1/4 One-touch Fitting, Piping Entry Direction: Straight, Output Specification: C [1 NPN Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -
Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Bottom Side, Output Specification: C [1 NPN Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: C4 [ø4 (5/32") One-touch Fitting], Piping Entry Direction: Straight, Output Specification: C [1 NPN Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -
10 to 60C (No freezing or condensation)Operating and stored: 35 to 85% RH (No condensation)1000 VAC for 1 min. between live parts and enclosure50 M or more between live parts and enclosure (at 500 VDC Mega)10 to 150 Hz, at the smaller of amplitude 1.5 mm or 20 m/s2 in X, Y, Z directions for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions 3 times each (De-energized)?2% F.S.
10 to 60C (No freezing or condensation)Operating and stored: 35 to 85% RH (No condensation)1000 VAC for 1 min. between live parts and enclosure50 M or more between live parts and enclosure (at 500 VDC Mega)10 to 150 Hz, at the smaller of amplitude 1.5 mm or 20 m/s2 in X, Y, Z directions for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions 3 times each (De-energized)?2% F.S.
10 to 60C (No freezing or condensation)Operating and stored: 35 to 85% RH (No condensation)1000 VAC for 1 min. between live parts and enclosure50 M or more between live parts and enclosure (at 500 VDC Mega)10 to 150 Hz, at the smaller of amplitude 1.5 mm or 20 m/s2 in X, Y, Z directions for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions 3 times each (De-energized)?2% F.S.
10 to 60C (No freezing or condensation)Operating and stored: 35 to 85% RH (No condensation)1000 VAC for 1 min. between live parts and enclosure50 M or more between live parts and enclosure (at 500 VDC Mega)10 to 150 Hz, at the smaller of amplitude 1.5 mm or 20 m/s2 in X, Y, Z directions for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions 3 times each (De-energized)?2% F.S.
10 to 60C (No freezing or condensation)Operating and stored: 35 to 85% RH (No condensation)1000 VAC for 1 min. between live parts and enclosure50 M or more between live parts and enclosure (at 500 VDC Mega)10 to 150 Hz, at the smaller of amplitude 1.5 mm or 20 m/s2 in X, Y, Z directions for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions 3 times each (De-energized)?2% F.S.
10 to 60C (No freezing or condensation)Operating and stored: 35 to 85% RH (No condensation)1000 VAC for 1 min. between live parts and enclosure50 M or more between live parts and enclosure (at 500 VDC Mega)10 to 150 Hz, at the smaller of amplitude 1.5 mm or 20 m/s2 in X, Y, Z directions for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions 3 times each (De-energized)?2% F.S.
ZSE10 compact, digital pressure switch for vacuum/compound pressure has been reduced in height by approximately 50% when compared to the ZSE30A. Up to 10 slave sensors can be set at once using the copy settings function. Options include direct mount, panel mount or DIN rail mount, and a choice of 2 piping directions., PRESSURE SWITCH, VACUUM SERIES, ZSE30 VACUUM SWITCH, 2X, OTHER
Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: B (PNP Open Collector 2 Outputs)
Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: A (NPN Open Collector 2 Outputs)
Piping Specifications: 01 (R1/8 Piping Adapter, Side Ported), Output Specifications: A (NPN Open Collector 2 Outputs)
Piping Specifications: 01 (R1/8 Piping Adapter, Side Ported), Output Specifications: B (PNP Open Collector 2 Outputs)
Piping Specifications: M5 (M5 Female Thread/Side Piping Port), Output Specifications: A (NPN Open Collector 2 Outputs)