CE-certified Symbol EX124D-SDN1-X188 DeviceNet (Negative common) Q A, B port size (Inch) A, B port size (Metric) P, E port Applicable series P, E port Applicable series A, B port Symbol C4 C6 C8 M A, B port Symbol N3 N7 N9 M One-touch fitting for 4 One-touch fitting for 6 One-touch fitting for 8 A, B ports mixed One-touch fitting for 5/32" One-touch fitting for 1/4" One-touch fitting for
(max. 20 stations) 3 SY3000 5 SY5000 Connector mounting position A, B port size Symbol Mounting position U U side SY5000 SY3000 D D side Symbol Port size 4 One-touch fitting C4 Symbol Port size 4 One-touch fitting C4 6 One-touch fitting C6 Mixed M 6 One-touch fitting C6 Valve stations 8 One-touch fitting C8 Mixed M Stations Symbol Note Single wiring specifications (up to 16 solenoids are
/C8/N7 2 -67No.PF-OMJ0005CN-I PFM7-C4L/C6L/C8L/N7L 2 -68No.PF-OMJ0005CN-I PFM7S-C4/C6/C8/N7 2 -69No.PF-OMJ0005CN-I PFM7S-C4L/C6L/C8L/N7L 2 -70No.PF-OMJ0005CN-I A 54 +0.5 0 74 +0.5 0 1 2R R3 313.2 mm (ZS-33-M) (ZS-33-MS) -71No.PF-OMJ0005CN-I (ZS-33-D (ZS-33-F) -72No.PF-OMJ0005CN-I INOUT X693 IN OUT X694 IN OUT 10 PFM7-C4/C6/C8/N7--X693 PFM7S-C4/C6/C8/N7--X693 A B A B C4 4(5/32) 10.1
Pressure Control Equipment Industrial Filters Port size Port size FN1 FN4 Symbol 10 20 Rc1 Rc2 Applicable model Specifications FN1 FN1101 FN1102 FN1112 FN4102 65 x 250L 65 x 500L Model Element dimension Material Construction Stainless steel 304 Element Cylindrical type 5 m, 20 m Step type 5 m Cylindrical type 5 m, 20 m Step type 5 m Cylindrical type 5 m, 20 m Nominal filtration rating Differential
/Wiring bottom entry ISE35-N-65-MLA ISE35-N-65-M PNP output/Wiring top entry ISE35-R-65-MLA ISE35-R-65-M N.O.
/Wiring bottom entry ISE35-N-65-MLA ISE35-N-65-M PNP output/Wiring top entry ISE35-R-65-MLA ISE35-R-65-M N.O.
(max. 20 stations) 3 SX3000 5 SX5000 Connector mounting position Symbol Mounting position U U side D D side Valve stations A, B port size Note Symbol 02 Stations SX3000 SX5000 2 stations Port size 4 One-touch fitting 6 One-touch fitting Mixed Symbol Port size 4 One-touch fitting 6 One-touch fitting 8 One-touch fitting Mixed Symbol C4 C6 M Double wiring specification C4 C6 C8 M 08 02 8 stations
DC1224 V10 DC1224 V10 9 DC(+) DC(-) / / 10 ( ) 11 / 5 m / 12 1015 10 "-M" (kPaMPa) ( ) "-M" 13 SI kPa,MPa -57No.PS-OMM0006CN-E No. 14 15 , 16 FUNC 17 4 m 4 m FUNC 18 10 10 () 19 () ( ) () / -58No.PS-OMM0006CN-E , 80 mA 7F.S.(3.5F.S.) 1 1F.S. 1 -59No.PS-OMM0006CN-E (M8(3 )62 ) ZSE40A() ZSE40AF() ISE40A() 0-101.3 kPa -100.0100.0kPa -0.1001.000 MPa 10.0-105.0 kPa -105.0105.0kPa
Reduced apparent power 10 VA m 7 VA (Size 1) Normally Closed (N.C.)
/N.O. 0.51 0.26 0.7 0.51 0.23 1/8 Single Double Closed center Exhaust center Pressure center 2position Note) [ ]: Indicates normal position 1.5 0.33 0.33 2.0 0.37 0.52 1.3 0.39 0.31 0.32 0.33 1.6 C6 6 Onetouch fitting 3position 1.8 [1.4] 0.35 [0.37] 0.44 [0.35] Series 53-SY9000 1.3 0.33 0.33 53-SY5 20-C6 Port size Flow-rate characteristics 1.7 [0.80] 0.44 0.31 [0.47] 0.33 0.42 [0.23] 1.7
L D-A73 (Example) 20Lead wire length Data 5 m None Nil L 0.5 m 3 m Z N Applicable for the connector type (D-C) only.
How to Order Manifold Assemblies (Example) How to Order Valves Example (SZ3000, positive common with power supply terminals) SZ3 5 1 C6 LOZ 60 Double solenoid SZ3260-5LOZ-C6 (3 sets) Single solenoid SZ3160-5LOZ-C6 (2 sets) Type of actuation Supply/Exhaust block (U side mounting) 1 2 3 4 5 A B C 2 position single solenoid 2 position double solenoid 3 position closed center Switch specifications
Series: 3 (JSY3000), Type: 10S (Side-Ported, Serial Interface, EX260), SI Unit: EA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: NPN, Positive Common, Valve Stations: 8 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), A,B Port Size: C6 (ø6 One-touch Fitting)
Series: 3 (JSY3000), Type: 10S (Side-Ported, Serial Interface, EX260), SI Unit: EA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: NPN, Positive Common, Valve Stations: 6 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), A,B Port Size: C6 (ø6 One-touch Fitting)
Series: 3 (JSY3000), Type: 10S (Side-Ported, Serial Interface, EX260), SI Unit: EB (EtherNet/IPâ„¢ - 16 Outputs - Connector M12), SI Unit Output Polarity: NPN, Positive Common, Valve Stations: 6 Stations, P,E Port Location: D (D Side, 2 to 10 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C6 (ø6 One-touch Fitting)
Series: 3 (JSY3000), Type: 10 (Side-Ported), Connector Type: FW (D-sub Connector, IP67, 25 Pins), Connector Entry Direction: 1 (Upward), Valve Stations: 4 Stations, P,E Port Location: D (D Side, 2 to 10 Stations), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), A,B Port Size: C6 (ø6 One-touch Fitting)
Series: 3 (JSY3000), Type: 10 (Side-Ported), Number of Cores - Lead Wire: L3 (9 Cores), Lead Wire Length: 2 (1.5m), Valve Stations: 4 Stations, P,E Port Location: U (U Side, 2 to 10 Stations), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), A,B Port Size: C6 (ø6 One-touch Fitting)
Series: 3 (JSY3000), Type: 10S (Side-Ported, Serial Interface, EX260), SI Unit: KA (IO-Link - 32 Outputs - Connector M12), SI Unit Output Polarity: N (PNP, Negative Common), Valve Stations: 3 Stations, P,E Port Location: U (U Side, 2 to 10 Stations), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), A,B Port Size: C6 (ø6 One-touch Fitting)
Series: 3 (JSY3000), Type: 10S6 (Side-Ported, Serial Interface, EX600), SI Unit: 0 (w/o SI Unit), SI Unit Common, End Plate: w/o SI Unit, I/O Unit Stations: None, Valve Stations: 8 Stations, P,E Port, SUP/EXH Assembly: B (Internal Pilot, Both Sides, 2 to 24 Stations), A,B Port Size: C6 (ø6 One-touch Fitting)