W (44) Z (X) (V) T R (Y) T 25 IN port 2-3/8 l=280 l=300 2.5 (N) E A (U) S Q D G C C B L1 L2 L3 16 D side U side Stations 1 2 3 4 5 n 21 5.5 16 OUT port n-1/4 n-1/8 H H P=J (Pitch) 2 : Thread type L dimensions (mm) n (stations) Model Dimension 2 3 4 6 9 7 5 8 10 L1 69 103.5 138 207 310.5 241.5 172.5 276 345 VV2CW2 L2 81 115.5 150 219 322.5 253.5 184.5 288 357 L3 93 127.5 162 231 334.5 265.5
Local Area: (800) 258-9200-www.stevenengineering.com Fluid Air/Inert gas VT 1.0 MPa Maximum operating pressure Minimum operating pressure 0.1 MPa VP 1.5 MPa Proof pressure Ambient and fluid temperature 10 to 50C Lubrication Not required Dusproof (5) VG Enclosure Manual override Push type (Safety style), Locking type (Tool required), Locking type (Manual) VP Shock/Vibration resistance (m/s2) 150
L V V 100 REBHT32 REBH(T)25 10 Load weight W (kg) REBH15 1 0.1 100 200 300 400 600 500 Maximum speed U (mm/s) 73 Series REBH Model Selection 3 Selection Calculation The selection calculation finds the load factors (n) of the items below, where the total (n) does not exceed 1. n = 1 + 2+ 3 1 Load factor n 1 = W/Wmax Note Item Review W.
V Ps + 0.1 293 S = 12.1 log10 () (6) t P + 0.1 T S : Effective area [mm2] V : Air tank capacity [L] t : Discharging time [s] Ps : Pressure inside air tank before discharging [MPa] P : Residual pressure inside air tank after discharging [MPa] T : Temperature inside air tank before discharging [K] Power supply Pressure switch Thermometer Pressure control equipment Control circuit Solenoid
2.0% F.S. or less (0 to 50C, based on 25C)NPN open collector Max. load current: 80 mA; Max. applied voltage: 30 V; Internal voltage drop: 1 V or less (with load current of 80 mA)PNP open collector Max. load current: 80 mA; Internal voltage drop: 1.5 V or less (with load current of 80 mA)NPN or PNP open collector Flow rate per pulse: 100 l/pulse, 10.0 ft3/pulseON time per pulse
2.0% F.S. or less (0 to 50C, based on 25C)NPN open collector Max. load current: 80 mA; Max. applied voltage: 30 V; Internal voltage drop: 1 V or less (with load current of 80 mA)PNP open collector Max. load current: 80 mA; Internal voltage drop: 1.5 V or less (with load current of 80 mA)NPN or PNP open collector Flow rate per pulse: 100 l/pulse, 10.0 ft3/pulseON time per pulse
2.0% F.S. or less (0 to 50C, based on 25C)NPN open collector Max. load current: 80 mA; Max. applied voltage: 30 V; Internal voltage drop: 1 V or less (with load current of 80 mA)PNP open collector Max. load current: 80 mA; Internal voltage drop: 1.5 V or less (with load current of 80 mA)NPN or PNP open collector Flow rate per pulse: 100 l/pulse, 10.0 ft3/pulseON time per pulse
2.0% F.S. or less (0 to 50C, based on 25C)NPN open collector Max. load current: 80 mA; Max. applied voltage: 30 V; Internal voltage drop: 1 V or less (with load current of 80 mA)PNP open collector Max. load current: 80 mA; Internal voltage drop: 1.5 V or less (with load current of 80 mA)NPN or PNP open collector Flow rate per pulse: 100 l/pulse, 10.0 ft3/pulseON time per pulse
Not required (Use turbine oil Class 1 ISO VG32, if lubricated.) 5 to 50C (Air operated type: 60C) PA AC (50/60 Hz) DC VNC1 VNC Applicable pressure range 100 V, 200 V, Other voltage (Option) Coil rated voltage (V) 2 4 PAX 24 V, Other voltage (Option) 15% to +10% of rated voltage Class B or equivalent (130C) 1 4 VNC Allowable voltage fluctuation Coil insulation type Pressure VNC2 PB External
2.0% F.S. or less (0 to 50C, based on 25C)NPN open collector Max. load current: 80 mA; Max. applied voltage: 30 V; Internal voltage drop: 1 V or less (with load current of 80 mA)PNP open collector Max. load current: 80 mA; Internal voltage drop: 1.5 V or less (with load current of 80 mA)NPN or PNP open collector Flow rate per pulse: 100 l/pulse, 10.0 ft3/pulseON time per pulse
C J G5-S 150 cm3/min or less 200 cm3/min or less 300 cm3/min or less Supply pressure 0.1 MPa Total allowable leakage 800 cm3/min or less 1000 cm3/min or less 1200 cm3/min or less Weight/Standard Type: MQQT Supply pressure 0.3 MPa CV 1500 cm3/min or less 2000 cm3/min or less 3000 cm3/min or less Supply pressure 0.5 MPa (g) Note 1) Use clean, dry air with no freezing.
200 150 100 0 50 Supply pressure (kPa) Supply pressure (kPa) 870 Air Catch Sensor Series ISA2 Response Time (Typical example) Response time changes with detection distance and piping length.
Piston speed (3) 150 cm3/min or less 200 cm3/min or less 300 cm3/min or less Supply pressure 0.1 MPa Total allowable leakage MQQ M 800 cm3/min or less 1000 cm3/min or less 1200 cm3/min or less Supply pressure 0.3 MPa 1500 cm3/min or less 2000 cm3/min or less 3000 cm3/min or less Supply pressure 0.5 MPa RHC Note 1) Use clean, dry air with no freezing.
Performance Data S Series Swivel (1/4", 3/8", 1/2", 3/4") Test Fluid: Oil 150 SUS vs. Pressure Drop 40 35 3/8" Features 3/4" 1/2" 30 3000 psi working pressure rating for all sizes. D Swivels Pressure Drop in PSID Variety of seal options. 25 Torque value does not significantly increase with pressure.
Refrigerant R407C (HFC) Series IDF100FS/125FS/150FS Applicable Compressor Size: 100 kW, 125 kW, 150 kW (Max. inlet air temperature: 140F (60C) (Max. ambient temperature: 113F (45C) RoHS How to Order IDF 30 100 FS Nil C K P R V Nil 1 2 3 Size Size Air compressor size Note) 100 100 kW 125 125 kW 150 150 kW Note) Note that the above values are for reference only.
Note) X465 AMR Note) Except symbol G ITV IC Switch specifications Output specifications NPN output PNP output 1 to 5 V output 4 to 20 mA output Symbol A B C D VBA VE VY1 With digital pressure switch G PPA Note 1) Please contact SMC separately for details about the external dimensions, etc.
R R 1. 2. 2 9 - 3-7 1 ON OFF ON ON 1 2 1 1 1 2 3 3 0.3~0.5mm 4 5 0.3~0.5mm 10 - 2 ON OFF ON ON 1 2 1 1 1 2 3 3 0.3~0.5mm 4 5 0.3~0.5mm 11 - M2.54 5 6 5~6mm 0.05~0.1 Nm90 D-Y59/Y69/Y7P/Y7PV D-M9(V) D-Y7W/Y7WV D-M9W(V) D-M9A(V)L MHL2-10D 0.8 0.3 MHL2-16D 0.5 0.4 MHL2-20D 0.5 0.7 ON MHL2-25D 0.5 0.6 OFF MHL2-32D 0.5 0.6 MHL2-40D 0.5 0.9 1. 2. 12 - 3-8
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Solenoid Specifications Option Grommet (G)/(H), L plug connector (L), M plug connector (M), DIN terminal (D) Electrical entry For manifold use, refer to the pages 4-6-8 to 4-611. 100, 200, 24, 48, 110, 220 AC50/60 Hz DC Coil rated voltage (V) 24, 6,
male connector S F TX Different diameter cross Male elbow Female connector TY Different diameter cross Union elbow Male run tee Y L Plug-in elbow Delta union Male delta union D Reducer elbow Male branch connector Branch Universal female elbow VS Hexagon socket head universal male elbow Universal male elbow K 45 male elbow Branch union elbow LU Union Y U Different dia. union Y Plug-in Y V
or less 25 24V 25 Relay, PLC Connector 24 V or less 100V IC circuit 3-wire Grommet 10 2-wire 24V IC circuit 100 V or less Solid state auto switches marked with are produced upon receipt of order.