NCA1-325 NCA1-800 NCA1-1000 CD 3/4 1 1 3/8 Part No. NCDP-325 NCDP-800 NCDP-1000 CD 3/4 1 1 3/8 DD .140 .140 .173 CL 3.10 3.60 4.66 Note: Retainer rings are included. Note: Cotter pins are included. Rod Jam Nut Rod Eye 2xCD CB ER CD Thread CD F CA H C A KK Dimensions Dimensions Thread 3/4-16UNF 1-14UNF 1 1/4-12UNF Part No.
AS301FS, AS311FS AS401FS, AS411FS Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 10, 11, 12 10, 11, 12 12, 13, 16 12, 13, 16 1500 1000 10, 11 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 08, 09 06, 07 1000 500 500 0 0 5 0 10 5 0 10 Number of needle rotations Number of needle rotations Note) The numbers above the flow rate characteristic curves in the charts show the applicable tubing
cushion Allowable kinetic energy Rubber bumper 0.02 J 0.03 J 0.04 J 0.09 J 0.27 J 0.4 J Symbol Air cushion 0.17 J 0.19 J 0.4 J 0.66 J 0.97 J Air cushion Double acting, Single rod Standard Strokes Bore size [mm] Standard stroke [mm]*2*4 Max. stroke*3 [mm] 8*1 10, 25, 40, 50, 80, 100 200 10 400 12 10, 25, 40, 50, 80, 100, 125, 160, 200 16 20 10, 25, 40, 50, 80, 100, 125, 160, 200, 250, 300 1000
350, 400, 450, 500, 600, 700, 800 1300 12-CY3R40 40 Rc1/4 NPT1/4 G1/4 12-CY3R50 12-CY3R63 50 63 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 Note 1) Stroke exceeding the standard stroke but below the maximum manufacturable stroke is available as special order.
Voltage limit V, 1 min, AC 1000 Insulation resistance MW/km, 20C 5 or more * The minimum bending inner radius of D-sub connector cable is 20 mm. 43 ZK2mA Series Specific Product Precautions 1 Be sure to read this before handling the products. Refer to the back cover for safety instructions.
(OUT1: Green, OUT2: Red) Enclosure IP40 Operating temperature range Operating: 0 to 50C, Stored: 10 to 60C (No freezing or condensation) Environmental resistance Operating humidity range Operating/Stored: 35 to 85% RH (No condensation) Withstand voltage 1000 VAC for 1 minute between terminals and housing Insulation resistance 50 M or more (500 VDC measured via megohmmeter) between terminals
Assuming that the tube I.D. is 2 mm, the piping capacity is as follows: V = /4 x D2 x L x 1/1000 = /4 x 22 x 1 x 1/1000 = 0.0031 L (2) Assuming that leakage (QL) during adsorption is 0, find the average suction flow rate to meet the adsorption response time using the formula on the front matter 17.
CE2 ML2B Graph (1) Graph (2) RSA50, 63, 80 Bore size 50, 63, 80/ = 0 Bore size 50, 63, 80/ = 0.1 C J G5-S 1.0 1300 1300 RSH80 RSA80 RSH63 RSA63 RSH50 RSH50 RSA50 80 0.9 Operating pressure P [MPa] 1200 1200 CV 0.8 1100 1100 0.7 MVGQ 1000 1000 0.6 900 900 0.5 CC 63 80 Load weight m [kg] Load weight m [kg] 800 800 0.4 50 0.3 RB 700 700 0.2 600 600 J 0.1 63 500 500 50 1000 2000 3000 4000 5000
Rubber bumper50 to 750 mm/s (Standard equipment) Air cushion50 to 1000 mm/s DReduced piston rod deflection -X The clearance between the bushing and the piston rod, and between the tube and the wear ring have been decreased to achieve higher accuracy.
Y-strainer Rc1/2 #500 to 1000 Install either the strainer or filter. If foreign objects with a size of 20 m or more are likely to enter, install the particle filter. 2 Filter Rc1/2 20m HRS-PF003 3 Flow meter 0 to 50L/min 4 Pressure gauge 0 to 1.0MPa 5 Others (pipe, hose, etc.) 15 or more Y-strainer Rc1/2 #1000 Install either the strainer or filter.
Crean class Amount of Type Speed recommended vacuum (mm/s) ISO 14644-1 Fed.Std.209D aspiration 6 1000 10 5 100 20 4 10 30 6 1000 50 5 100 60 4 10 70 6 1000 20 5 100 30 4 10 50 6 1000 30 5 100 70 4 10 90 600 11-LEJS40 1200 600 *Please aspirate it from the port on both sides when aspirating 50/min(ANR). Please select "D" about the type. 11-LEJS63 1200 * Based on SMC test condition.
200 1000 2 2 50 200 50 200 3 3 CN1 DC24V 2) USB (A-miniB type ( <> AWG20 (0.5mm 2) (, USB ) LEC-W2 1 2UL ,UL1310 Class2 (3m LEC-T1-3JG* (LEC ) 6.
200 1000 2 2 A-miniB type 50 200 50 200 3 3 CN2 CN2TB/PC 27 - 6.CN4 6.1 No.
212 148 162 50 59 86 40 16 28 90 16 93 92 25 171 1000 (1001 to 1400) 119 (124) 18 (28) 130 (164) 76 (84) 160 (198) 53 (59) 204 (215) 0.040 0.073 80 1400 750 750 750 25 116 112 102 112 31.5 110 13.5 13.5 140 45 61 129 204 4.5 44 16 27 247 48 28 235 255 192 194 65 76 45 20 34 20 205 1000 (1001 to 1500) 133 (140) 18 (29) 150 (180) 92 (100) 180 (220) 54 (60) 215 (227) 0.040 0.073 100 1500 750
style (D-A73C/A80C) and A9/A9 V style: 1000 V AC/min.
MHF Type Solid state switch Reed switch 3-wire: 100 A or less, 2-wire: 0.8 mA or less (4) Leakage current None MHL Note 2) Operating time 1 ms or less (3) 1.2 ms Impact resistance 1000 m/s2 300 m/s2 MHR 50 M or more at 500 M VDC (Between lead wire and case) Insulation resistance Note 3) MHK 1000 VAC for 1 minute (Between lead wire and case) 1500 VAC for 1 minute (1) (Between lead wire and
M = W x 9.8 (Ln + An)/1000 Corrected value of moment center position distance An: Table (1) Examine Mr. Mr = 0.2 x 9.8 (40 + 15.5)/1000 = 0.1 A2 = 15.5 Obtain Mar = 13 from Va = 300 in Graph (3). Find the allowable static moment Ma (Nm). Pitch, Yaw moment: Graph (2) Roll moment: Graph (3) 13 Find the load factor 1 of the static moment.
(Between lead wire and the case) 1000 m/s2 300 m/s2 Impact resistance 50 M or more at 500 M VDC (Between lead wire and case) Insulation resistance 1500 VAC for 1 minute 1) (Between lead wire and case) 1000 VAC for 1 minute (Between lead wire and case) Withstand voltage Except magnetic resistant 2-color indication type solid state switch (DP5DWL/P5DWSC).
Refrigerant Air connection 300 2.2 IDU3D 350 Series IDU High inlet air temperature type Rated temperature of 50 to 60C Rc 3/8 60C 430 3.7 IDU4D 500 Small Medium Small Medium Large R134a 1 to 4 R 1/2 640 5.5 IDU6D 750 55C R 3/4 Air cooled Air cooled 850 7.5 IDU8D 1000 IDU11D R134a 1300 11 R 3/4 1500 IDU11C 1300 55C 2400 IDU15C 15 2050 R 1 3700 IDU22C/22C1 22 3150 R22 5 to 8 6100 IDU37C/37C1
500 3000 0 0 2500 2000 1500 1000 500 3000 Flow rate l/min (ANR) Flow rate l/min (ANR) ARBQ5000-00-P (PA) ARBQ5000-00-P (PB) 0.7 0.7 0.6 0.6 Downstream pressure MPa Downstream pressure MPa 0.5 0.5 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0 0 2500 2000 1500 1000 500 3000 0 0 2500 2000 1500 1000 500 3000 Flow rate l/min (ANR) Flow rate l/min (ANR) Note: 1MPa = 145psi 1l/min = 0.035SCFM Pressure Characteristics