This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, ACTUATOR, ELECTRIC ACTUATOR, LC, 32MM LE ELECTRIC ACTUATOR, 13.22038 lb
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, ACTUATOR, ELECTRIC ACTUATOR, MC, 40MM LE ELECTRIC ACTUATOR, 26.01454 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, ACTUATOR, ELECTRIC ACTUATOR, PC, 63MM LE ELECTRIC ACTUATOR, 50.21027 lb
A high rigidity, slider type electric actuator, series LEJ is available in both ball screw, LEJS, and belt drive, LEJB models. The LEJ offers 2 types of motor cables, standard and robotic (flexible). Seal bands, equipped as standard, cover the guide preventing grease from splashing, and external foreign matter from entering. LEJS (ball screw drive) can be used for both horizontal and
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, ACTUATOR, ELECTRIC ACTUATOR, PC, 63MM LE ELECTRIC ACTUATOR
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
A high rigidity, slider type electric actuator, series LEJ is available in both ball screw, LEJS, and belt drive, LEJB models. The LEJ offers 2 types of motor cables, standard and robotic (flexible). Seal bands, equipped as standard, cover the guide preventing grease from splashing, and external foreign matter from entering. LEJS (ball screw drive) can be used for both horizontal and
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ELECTRIC ACTUATOR, ACTUATOR, ELECTRIC ACTUATOR, IC, 25MM LE ELECTRIC ACTUATOR, 21.36720 lb, ModelActuator specificationsElectric specificationsLock unit specificationsStroke [mm] Note 1)Work load [kg] Note 2)Note 3) Max. speed [mm/s]Max. acceleration/deceleration [mm/s2]Positioning repeatability [
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.High output motor
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, ACTUATOR, ELECTRIC ACTUATOR, IC, 25MM LE ELECTRIC ACTUATOR, 13.22773 lb
AS3201F, AS3211F AS3301F, AS3311F AS4201F, AS4211F AS4301F, AS4311F Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 12, 13, 16 10, 11, 12 1500 1000 10, 11 Flow rate L/min (ANR) Flow rate L/min (ANR) 08, 09 06, 07 1000 500 500 0 0 5 0 10 5 0 10 Number of needle rotations Number of needle rotations Note) The numbers above the flow rate characteristic curves in the charts show the applicable
Recommended shim thickness) Arm length L: 4 in 0.04 0.02 0.06 500 Clamping force (lbf) Peak clamping force position 400 0.7 MPa 300 0.5 MPa 0.3 MPa 200 100 0 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 Shim thickness (in) 50 Arm length L: 150 mm 2000 Clamping force (N) 1500 0.7 MPa 0.5 MPa 0.3 MPa 1000 500 0 0.5 0 1 1.5 2 3 4 5 6 7 8 9 Shim thickness (mm) (Ex. Recommended shim thickness) (Ex.
With Bypass Valve (Flange size: 80) (40) 148.5 3 117 (40) I G H H V A C 117 A U U M E V V A L Lead wire length: 500 mm (L type: 3000 mm) (40) XLA-16-X65 e u t w y Pilot port: Rc1/8 Bypass valve adjustment nut (Initial exhaust) Adjustment pitch: 1 mm/rotation Shaft seal (FKM) r Scraper (FKM) Pilot port: M5 0.2 Lock nut Width across flats 13 96 90 235 (Max. 13) 7.5 8-2 112 114 83 8-1 i !
With Bypass Valve (Flange size: 80) (40) 148.5 3 117 (40) I G H H V A C 117 A U U M E V V A L Lead wire length: 500 mm (L type: 3000 mm) (40) XLA-16-X65 e u t w y Pilot port: Rc1/8 Bypass valve adjustment nut (Initial exhaust) Adjustment pitch: 1 mm/rotation Shaft seal (FKM) r Scraper (FKM) Pilot port: M5 0.2 Lock nut Width across flats 13 96 90 235 (Max. 13) 7.5 8-2 112 114 83 8-1 i !
P. 13 How to Order Separately installed transformer Base integrated with a transformer IDF TR 500 2 IDF TB 403 Capacity Source voltage Size order Applicable dryer IDF1E-10 to IDF8E-10 IDU3E-10, IDU4E-10 Symbol Capacity Outlet voltage Model Inlet voltage 110 VAC (50 Hz), 110 to 120V(60 Hz) Symbol Symbol 403 Applicable dryer IDF4E to 8E, IDU3E to 4E 500 1 500 VA Single turn Please refer to
Indicator light DC (+) Brown 8 3.2 2.6 2 4.6 4 2.7 4 2.8 Most sensitive position 6 2.8 22 500 (3000) 20 2.7 OUT Black 3.2 DC () Blue 2.6 9.5 6 Most sensitive position 22 500 (3000) 4 D-M9B, D-M9BV OUT (+) Brown Precautions Be sure to read before handling.
M2.5 x 4l Slotted set screw Indicator light ML2B 8 3.2 DC (+) Brown 2.6 2 4.6 4 C J G5-S 2.7 4 2.8 Most sensitive position 6 2.8 22 500 (3000) 20 2.7 CV OUT Black 3.2 2.6 DC () Blue MVGQ 9.5 6 Most sensitive position 22 500 (3000) 4 D-M9B, D-M9BV CC Precautions OUT (+) Brown RB Be sure to read before handling.
Air filter (5 m or less) IR (Precision regulator) W D0.5 to 500 MQQL Anti-lateral load type (Built-in ball bushing) 0.005 to 0.7 When using a solenoid valve, use a metal seal type (Series VQ/VQZ/SQ, etc.).
90 0.5 W W W 0.5 F 117 108 95 76 0.7 C J G5-S 0.1 0 500 1000 1500 81 75 66 51 0.3 CV G 60 55 49 37 0.5 Cylinder stroke (mm) The above curve in the graph refers to P = 0.5 MPa of supply pressure.