A Withstand pressure V, 1 minute, AC Station 11 1000 SOL. B 24 () (+) Black White 12 () (+) Yellow Red SOL. A Insulation resistance M/km, 20C Station 12 5 or less SOL. B 25 () (+) White None Note) The minimum bending radius for D-sub connector cables is 20mm. COM. 13 (+) () Orange Red Note) Negative COM spec. Positive COM spec.
0.5 0.6 0.7 0.8 0.9 1.0 200 CM2 20 50% 70% 10% 30% 150 Stroke mm AS2201F -01-06 AS2200-01 70% 100 50 10% 30% 50% 0 200 CM2 25 150 Stroke mm AS2201F -01-06 AS2200-01 100 50 0 ANA1 -C08 T0604 200 CM2 32 150 Stroke mm AS2201F -01-06 AS2200-01 100 50 0 200 CM2 40 150 Stroke mm AS2201F -02-06 AS2200-02 100 50 0 Solenoid valve Silencer Tubing Speed controller 200 300 400 500 600 700 800 900 1000
CE2 ML2B Graph (1) Graph (2) RSA50, 63, 80 Bore size 50, 63, 80/ = 0 Bore size 50, 63, 80/ = 0.1 C J G5-S 1.0 1300 1300 RSH80 RSA80 RSH63 RSA63 RSH50 RSH50 RSA50 80 0.9 Operating pressure P [MPa] 1200 1200 CV 0.8 1100 1100 0.7 MVGQ 1000 1000 0.6 900 900 0.5 CC 63 80 Load weight m [kg] Load weight m [kg] 800 800 0.4 50 0.3 RB 700 700 0.2 600 600 J 0.1 63 500 500 50 1000 2000 3000 4000 5000
NCA1-325 NCA1-800 NCA1-1000 CD 3/4 1 1 3/8 Part No. NCDP-325 NCDP-800 NCDP-1000 CD 3/4 1 1 3/8 DD .140 .140 .173 CL 3.10 3.60 4.66 Note: Retainer rings are included. Note: Cotter pins are included. Rod Jam Nut Rod Eye 2xCD CB ER CD Thread CD F CA H C A KK Dimensions Dimensions Thread 3/4-16UNF 1-14UNF 1 1/4-12UNF Part No.
How to Order AL800 AL 23 80 12 0 R AL900 Semi-standard R Flow direction: Right Left Body size Port size Semi-standard Lubricator 1 1S-1 1S-2 2 3 6 8 1000 cm3 tank 1000 cm3 tank with switch (Bottom limit ON) 1000 cm3 tank with switch (Bottom limit OFF) Metal bowl With drain cock Nylon bowl (Including sight dome) Metal bowl with level gauge Symbol 12 14 20 4 1 1 1 2 2 1 80 90 1 2 2 1 Thread
Refer to Features 1 for details. 57 Filter Regulator AW10 to 40 Flow Characteristics (Representative values) Condition: Inlet pressure 0.7MPa AW10 AW30 Rc 3/8 AW40-06 Rc 3/4 M5 0.6 0.6 0.6 0.5 0.5 0.5 Outlet pressure MPa Outlet pressure MPa Outlet pressure MPa 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0 150 125 100 75 50 25 0 1000 0 3000 4000 1000 2000 Flow rate L/min (ANR) 0 0 0 500
40 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 50 6000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 63 Note1) Contact P/A in case of a stroke length beyond the maximum.
200, 250, 300 63 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100 MGGL Ball bushing 80 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200 100 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1300 Intermediate strokes and short strokes other than the above are produced upon receipt of order.
For product installation at a place of high altitude of 1000 meters or more, select a thermo-chiller of the applicable capacity referring to the table below. 1. Max. ambient temp.: Use the product in lower ambient temperature than the described value at each altitude. 2.
AS301FS, AS311FS AS401FS, AS411FS Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 10, 11, 12 10, 11, 12 12, 13, 16 12, 13, 16 1500 1000 10, 11 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 08, 09 06, 07 1000 500 500 0 0 5 0 10 5 0 10 Number of needle rotations Number of needle rotations Note) The numbers above the flow rate characteristic curves in the charts show the applicable tubing
cushion Allowable kinetic energy Rubber bumper 0.02 J 0.03 J 0.04 J 0.09 J 0.27 J 0.4 J Symbol Air cushion 0.17 J 0.19 J 0.4 J 0.66 J 0.97 J Air cushion Double acting, Single rod Standard Strokes Bore size [mm] Standard stroke [mm]*2*4 Max. stroke*3 [mm] 8*1 10, 25, 40, 50, 80, 100 200 10 400 12 10, 25, 40, 50, 80, 100, 125, 160, 200 16 20 10, 25, 40, 50, 80, 100, 125, 160, 200, 250, 300 1000
350, 400, 450, 500, 600, 700, 800 1300 12-CY3R40 40 Rc1/4 NPT1/4 G1/4 12-CY3R50 12-CY3R63 50 63 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 Note 1) Stroke exceeding the standard stroke but below the maximum manufacturable stroke is available as special order.
Voltage limit V, 1 min, AC 1000 Insulation resistance MW/km, 20C 5 or more * The minimum bending inner radius of D-sub connector cable is 20 mm. 43 ZK2mA Series Specific Product Precautions 1 Be sure to read this before handling the products. Refer to the back cover for safety instructions.
(OUT1: Green, OUT2: Red) Enclosure IP40 Operating temperature range Operating: 0 to 50C, Stored: 10 to 60C (No freezing or condensation) Environmental resistance Operating humidity range Operating/Stored: 35 to 85% RH (No condensation) Withstand voltage 1000 VAC for 1 minute between terminals and housing Insulation resistance 50 M or more (500 VDC measured via megohmmeter) between terminals
Assuming that the tube I.D. is 2 mm, the piping capacity is as follows: V = /4 x D2 x L x 1/1000 = /4 x 22 x 1 x 1/1000 = 0.0031 L (2) Assuming that leakage (QL) during adsorption is 0, find the average suction flow rate to meet the adsorption response time using the formula on the front matter 17.
CE2 ML2B Graph (1) Graph (2) RSA50, 63, 80 Bore size 50, 63, 80/ = 0 Bore size 50, 63, 80/ = 0.1 C J G5-S 1.0 1300 1300 RSH80 RSA80 RSH63 RSA63 RSH50 RSH50 RSA50 80 0.9 Operating pressure P [MPa] 1200 1200 CV 0.8 1100 1100 0.7 MVGQ 1000 1000 0.6 900 900 0.5 CC 63 80 Load weight m [kg] Load weight m [kg] 800 800 0.4 50 0.3 RB 700 700 0.2 600 600 J 0.1 63 500 500 50 1000 2000 3000 4000 5000
Rubber bumper50 to 750 mm/s (Standard equipment) Air cushion50 to 1000 mm/s DReduced piston rod deflection -X The clearance between the bushing and the piston rod, and between the tube and the wear ring have been decreased to achieve higher accuracy.
Cam Follower Guide Slider, ELECTRIC ACTUATOR, 8.72 lb
Cam Follower Guide Slider, ELECTRIC ACTUATOR, 10 lb
Cam Follower Guide Slider, ELECTRIC ACTUATOR, A22, 12.04 lb