Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 150/40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 150/40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 150/40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket:

200 250 0 0 50 100 150 200 Flow rate L/min (ANR) Flow rate L/min (ANR) ARM5AA1-308 (One-touch fittings: IN/OUT 6) Condition: Inlet pressure 0.7 MPa ARM5AA1-308-1 (One-touch fittings: IN/OUT 6) Condition: Inlet pressure 0.5 MPa 0.7 0.35 0.6 0.30 0.5 0.25 0.4 0.20 0.3 0.15 0.2 0.10 0.1 0.05 0 0 50 100 150 200 250 0 0 50 100 150 200 250 Flow rate L/min (ANR) Flow rate L/min (ANR) ARM5AA1-309

Cooling water (l/min) 180C Inlet air temperature Correction factor Air flow (l/min (ANR)) Model 50C 70C 100C 41.5 43 45.5 37 43 49.5 37 43 45.5 37 42 43.5 40 44 46 39.5 43 44.5 41 43 45.5 A B C A B C A B C A B C A B C A B C A B C 35.5 36 36.5 33.5 36 38 33.5 36 36.5 33.5 35 36 34.5 36 37 34.5 35.5 36 34.5 35.5 36 38.5 40 42 36 40 45.5 36 40 42.5 36 40 41 38 40 42.5 38

0 60 20 40 0 60 80 20 40 0 60 Moment (Nm) Moment (Nm) Moment (Nm) Vertical Operation Intermediate Stops The cushion effect (smooth start-up, soft stop) exists only before the stroke end in the stroke ranges indicated in the table below.

125 14-150 18-150 1 Series JS Construction 10, 16 20 to 63 Parts list Parts list No.

Cylinder Speed Chart Bore size Series CJ2 Pressure 0.5 MPa Load factor 50% Stroke 60 mm Series CM2 Pressure 0.5 MPa Load factor 50% Stroke 300 mm Series MB Pressure 0.5 MPa Load factor 50% Stroke 500 mm 6 10 16 20 25 32 40 40 50 63 80 100 Series Average speed (mm/s) 800 700 600 500 400 300 200 100 0 It is when the cylinder is extending that is meter-out controlled by speed controller which

size Lubrication Model Rubber Air M3 x 0.5 12-CY3B6 6 300 50, 100, 150, 200 M5 x 0.8 12-CY3B10 10 500 50, 100, 150, 200, 250, 300 15 1000 12-CY3B15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 12-CY3B20 20 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Rc1/8 NPT1/8 G1/8 25 12-CY3B25 (Both sides) Non-lube 32 12-CY3B32 1300 Rc1/4 NPT1/4 G1/4 12-CY3B40 40 100, 150, 200, 250

160.5 4 101.5 119 150 160.5 3 90 107.5 137.5 148 2 78.5 96 125 135.5 1 67 84.5 112.5 123 L1 L2 L3 L4 583 5 Port Solenoid Valve/Plug-in Unit 10-SQ1000 Kit (PC wiring system compatible flat ribbon cable) J Directional Control Valves Air Grippers Modular F.

Load mass Allowable moment MY1H/m MY1H/M MY1H/M MY1H/M 2 1 3 40 50 50 40 50 40 50 4 40 5 30 30 30 30 20 20 20 20 MY1H40 MY1H32 MY1H40 MY1H32 10 10 10 MY1H40 MY1H40 MY1H40 MY1H40 MY1H32 MY1H40 MY1H32 MY1H32 MY1H32 MY1H32 5 4 MY1H25 MY1H25 10 MY1H40 MY1H40 Load mass kg Moment Nm Moment Nm Moment Nm 5 4 5 4 MY1H32 MY1H32 MY1H25 MY1H25 MY1H25 3 MY1H25 MY1H25 MY1H20 MY1H20 3 3 2 MY1H25 MY1H25

Servo malfunction indicator PL For power supply switching A surge killer should be attached to the electromagnetic contactor and relay. 5Ry Power supply OFF 1MC ON SUP 1MC 5Ry SGDE servomotor Motor 1 1MC SGDE servo pack R U V 2 M 1MC T 3 W 4 1CN 150 PULS 1 2 3 4 5 6 Be certain to ground.

-X 545 C(L)KU32 Series Auto Switch Mounting 2 Auto Switch Mounting Height Applicable cylinder: C(L)KU32-X2321 C(L)KU32-X2322 D-P3DWA 44.5 23.5 D-M9V D-M9WV 40 35 D-A7 40 22 546 Auto Switch Mounting C(L)KU32 Series Auto Switch Mounting Bracket Part No.

mm 0.3 mm 0.03 mm 0.30 0.03 0.15 0.20 0.02 0.10 0.01 mm 0.10 0.01 0.05 0.05 mm 0.02 mm 0 0 0 Supply pressure [kPa] 75 100 125 150 175 200 225 Supply pressure [kPa] 75 100 125 150 175 200 225 Supply pressure [kPa] 75 100 125 150 175 200 225 Piping length: 5 m Piping length: 5 m Piping length: 5 m Reference pressure 0.06 Reference pressure 0.30 Reference pressure 0.60 The distance of switch

3.4 mounting hole Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 150 (Lead wire AWG#26) 22 5 6 22 20.5 3 2 11 1 7 6 5 12 12.3 12 25 M5 x 0.8 3 (EXH) port M5 x 0.8 2 (OUT) port M5 x 0.8 1 (SUP) port S070B-C-M5 Plug lead type 0.1 W with power saving circuit 6 150 (

E2 A10 10 96.5 62.5 23 20 134.5 72.5 51 30 144.5 82.5 40 180.5 92.5 77 50 190.5 102.5 N S U F GN GS 20 51.5 33.5 Construction p. 118 J K ZP Y B Buffer Assembly p. 126 10 97 63 23 20 135 73 51 30 145 83 40 181 93 77 50 191 103 25 3.5 6 M10 x 1 14 3 52 34 10 102 68 23 20 140 78 51 30 150 88 40 186 98 77 50 196 108 32 57 39 10 142 74 20 139 84 30 149 94 50 194 114 75 50 40 62 44 N6 U6 A14 6

NIL IDF 100 F 30 4 W C 5 G Size K Size Air compressor size Note) 100kW 125kW 150kW 100 125 150 P R Note) The value is referential. Confirm the capability of the compressor used.

Hz 50 20 11 60 17 7 50 40 18 60 35 12 50 50 21 60 45 17 Type Power Temp. High temp. water (D, E, N, P) (3) (3) (3) Inrush Holding Power Oil (Std.) Air (Std.) Water Vacuum (V, M) (Std.) AC VX21 80 60 99 120 183 60 60 60 AC DC Max. DC 60 40 40 40 40 Option Material (1) (2) Min. AC DC No.

1000 40 1000 1000 1000 1000 500 500 500 500 500 500 500 500 500 500 0 0 0 0 0 0 0 10 20 30 40 0 10 20 30 40 0 10 20 30 40 0 10 20 30 40 0 10 20 30 40 0 0 10 20 30 40 0 0 0 0 10 20 30 40 0 10 20 30 40 [] Circulating fluid temperature[] Circulating fluid temperature[] Circulating fluid temperature[] Circulating fluid temperature[] [] 0 10 0 10 20 30 40 Circulating fluid temperature[] Circulating

10 M10 x 1.25 24 22 19.5 17 20 32 12 18 12 40 6 38 M5 x 0.8 5.5 10 16 3.5 35.5 1/8 to 300 40 10 M14 x 1.5 24 30 27 19 26 40 16 19 13 50 8 47 M6 x 1.0 6 14 16 4 44 1/8 to 500 50 14 M18 x 1.5 40 35 32 27 32 50 20 21 14 58 11 58 M8 x 1.25 7 18 22 5.5 55 1/4 to 600 63 14 M18 x 1.5 40 35 32 27 38 60 20 21 14 58 11 72 M10 x 1.5 7 18 22 7 69 1/4 to 600 80 22 M22 x 1.5 60 40 37 32 50 75 25 28 20