Accessories (Options) Applicable model Bracket assembly AMF150 AMF250 AMF350 AMF450 AMF550 AMF650 AMF850 Symbol BM51 BM52 BM53 BM54 BM55 BM56 BM57 spring washer With cap bolt, AMF Refer to ''Precautions" on p.4.6-33. 4.6-27 Odor Removal Filter Series AMF AMF150 to AMF850 How to Order AMF 250 03 R B Option R IN, OUT reversal Body size Accessories (Optional) 150 1 8 250 1 4 350 3 8 450 1 2
Symbol Order Made P.4.6-21 4.6-15 Micro Mist Separator with Prefilter Series AMH AMH150 to AMH850 How to Order AMH 250 03 J B Body size Options J Drain guide 1/4B female thread R IN/OUT reversal 150 1 8 250 1 4 350 3 8 450 1 2 550 3 4 650 1 850 11 2 Accessories(Options) Description None Bracket Symbol T Element service indicator B N.C.auto drain C N.O.auto drain D Note) Refer to p.4.7-7
with check valve 300 250 Insertion force N KKA4 without check valve 200 KKA4 with check valve 150 100 KKA3 without check valve 50 KKA3 with check valve 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Charging pressure MPa 15-2-97 26 26 S Couplers Specific Product Precautions 3 Be sure to read before handling.
, 250, 300 Max. manufacturable stroke Size 25, 32, 40, 50 300 Strokes other than the above are produced upon receipt of order.
Ambient and fluid temperature Piston speed Cushion Thread tolerance JIS class 2 +0.8 0 +1.0 0 +1.25 0 +1.4 0 +1.8 0 to 100mm mm, 100 to 250mm mm, 250 to 630mm mm 630 to 1000mm mm, 1000 to 1200mm mm Stroke length tolerance Basic type (B), Axial foot type (L), Front flange type (F), Rear flange type (G), Single clevis type (C), Double clevis type (D), Center trunnion type (T), Front trunnion
It must be operated manually. 0.1 0.1 0 600 800 400 200 0 1000 Flow rate L/min (ANR) 0 500 1500 0 Flow rate L/min (ANR) AW40K-06 Rc 3/4 AW40K Rc 1/2 0.6 0.6 0.5 0.5 Outlet pressure MPa Outlet pressure MPa 0.4 0.4 0.3 0.3 Caution 1. Be sure to unlock the knob before adjusting the pressure and lock it after setting the pressure.
SUP=0.3MPa Calculating air consumption (for PA3000) 200 SUP=0.2MPa 150 Find the air consumption for operation with a 4Hz switching cycle and pilot air pressure of 0.3MPa from the air consumption graph.
SUP=0.3MPa Calculating air consumption (for PA3000) 200 SUP=0.2MPa 150 Find the air consumption for operation with a 4Hz switching cycle and pilot air pressure of 0.3MPa from the air consumption graph.
Multistage Ejector Series ZL112/212 Energy saving, large flow rate, 3 stage diffuser construction Series ZL112/212 Suction flow rate increased 250% and air consumption reduced 20% with 3 stage diffuser construction (Versus 1.3, one stage model) 1 stage performance Maximum suction flow rate l/min (ANR) Air consumption l/min (ANR) Vacuum pressure Q1 Q2 Q3 ZL112 100 200 ZL212 63 126 Q1 Q2 Q3
Setup software (SigmaWin+) is necessary for the setting of the parameter. 1 Please download setup software via our website. 2 Prepare USB cable (LEC-JZ-CVUSB) separately. 4.1 power supply specifications When using the DRIVER with single-phase, 200 V power input, set parameter Pn00B.2 to 1.
Setup software (SigmaWin+) is necessary for the setting of the parameter. 1 Please download setup software via our website. 2 Prepare USB cable (LEC-JZ-CVUSB) separately. 4.1 power supply specifications When using the DRIVER with single-phase, 200 V power input, set parameter Pn00B.2 to 1.
212.5 225 237.5 250 250 L3 173 185.5 198 198 210.5 223 235.5 248 260.5 260.5 How to Order
Speed Controller/In-line Type AS2000-N02-X800/AS3000-N03-X800/AS4000-N04-X800 P .G. information Point to Group Specialized Product Flow Characteristics AS3000-N03-X800 AS4000-N04-X800 AS2000-N02-X800 300 800 Flow rate L/min (ANR) Flow rate L/min (ANR) Flow rate L/min (ANR) 1500 250 600 200 1000 150 400 100 500 200 50 0 0 1 2 3 4 5 6 7 9 8 10 0 0 1 2 3 4 5 6 7 9 8 0 0 1 2 3 4 5 6 7 8 Number
SUP=0.3MPa Calculating air consumption (for PA3000) 200 SUP=0.2MPa 150 Find the air consumption for operation with a 4Hz switching cycle and pilot air pressure of 0.3MPa from the air consumption graph.
Normally closed (N.C.) (8A) 6 1.05 19 8 1.7 31 1.5 0.4 340 10 1.9 34 4.5 0.61 11 250 1.0 6 1.05 19 3 8 (10A) 8 1.7 31 340 0.4 10 2.4 43 (15A) 10 2.4 43 1 2 420 Note) Refer to p.4.0-14 the glossary for detail of max. operating pressure differential and max. system pressure.
Flow Speed 3/4B (21.6) 1B (27.6) 11/4B (35.7) 11/2B (41.6) 2B (52.9) 21/2B (67.9) 2 1.8 3B (80.7) 1.6 1.4 Flow speed (m/s) 1.2 1 4B (105.3) 0.8 5B (130.8) 0.6 6B (155.2) 0.4 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0.2 50 100 150 200 250 300 350 400 0 Flow
300 400500 1000 1500 100 200 300400 500 1000 1500 Piston speed (mm/s) 100 200 300400500 1000 1500 Piston speed (mm/s) 100 200 300400500 1000 1500 Piston speed (mm/s) Piston speed (mm/s) 8-11-7 8 Series MY1 Precautions Be sure to read before handling.
T-slot 2 dimensions Compatible Motors Switch Internal Circuit D-Y7GL Motor output (W) Motor model Brake Manufacturer Power supply voltage (VAC) Motor specification symbol Controller driver model + Brown lead wire 100/110 200/220 100 200 100/115 200/230 100/115 200/230 100/115 200/230 100/115 200/230 100/115 200/230 100/115 200/230 LC1-1B1H1Without brake (Horizontal specification) 50 Main
control Circulating fluid: Water 0 50 100 150 200 250 300 External piping: Bypass piping Elapsed time [Minute] Temperature stability 1.8C [1.0F] Cooling capacity10 kW/15 kW Set temperature range 41 to 95F [5C to 35C] Low-noise design 70 dB(A) Max. ambient temperature 113F [45C] Outdoor installation IPX4 24.2 [616] Compact, Space-saving 37.5 [954] Added Variations!