16 16 16 L=120mm L=120mm L=120mm MXP16-20 MXP16-30 MXP16-20 MXP16-30 0.08 0.12 0.06 MXP16-20 MXP16-30 MXP16-20 MXP16-30 MXP16-20 MXP16-30 MXP16-20 MXP16-30 0.10 Table deflection (mm) Table deflection (mm) Table deflection (mm) 0.06 0.04 0.08 0.04 0.06 0.04 0.02 0.02 0.02 0 0 0 50 200 250 Load (N) 150 100 50 200 250 Load (N) 150 100 100 400 500 Load (N) 300 200 1 N = 0.2248 lbf 165 Series
250 300 100 0 50 150 200 250 300 100 ()[] ()[] LECSC-S5 LECSC-S7, LECSC-S8 . ()30r/min100% 12.1 12 2 12 12.2 (1) 12.1 12.1 1 (2)[W] (1) [m2] [kVA] LECSC-S5 LE-S5LE-S60.3 25 15 0.5 LECSC-S7 LE-S70.5 25 15 0.5 LECSC-S8 LE-S80.9 35 15 0.7 1.
SUP = 0.2 MPa 0.2 0.2 0.2 0.1 0.1 0.1 0 0 0 50 100 150 200 0 Discharge (mL/min) 0 Discharge (mL/min) 200 400 600 800 1000 0 Discharge (mL/min) 200 400 600 800 1000 Air Consumption: Built-in Solenoid Valve/Air Operated Calculation of Air Consumption Air Consumption 45 Find the air consumption for operation with a 5 Hz switching cycle and pilot air pressure of 0.35 MPa from the air consumption
AXT632-69-1 AXT632-69-2 VVCA30-3A-04-2 VVCA30-3A-04-1 OR-2200-200-H VCA35--VVCA30-6-n VVCA30-4A-04-2 VVCA30-4A-04-1 Material Part no.
300 5001000 0 50 Please consult with SMC regarding the maximum load weight for long strokes depending on your specific usage conditions.
20 9 8 7 6 5 6 5 4 (steel pipe I.D.) 4 3 2 7 6 5 4 3 2 20 30 40 50 60 80 100 200 300 400 500 2.8 Flow velocity inside pipe (m/s) Piston speed (mm/s) How to read the chart: Example) The required flow rate necessary to operate a 50 cylinder at a speed of 100mm/s is 12l/min.
[Option] Electrical entry D: DIN terminal DO : DIN terminal (Without connector) G: Grommet (Lead wire length: 300 mm) H: Grommet (Lead wire length: 600 mm) Rated voltage Valve option Rated voltage Nil V Y W E DC AC CE-compliant 1 2 3 4 5 6 7 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz 24 VDC 12 VDC 240 VAC, 50/60 Hz For the connector part number, refer to page
For details, refer to the Best Pneumatics Vol. 3. 4-5-1 2 Series VK300 How to Order Electrical entry D: DIN terminal DO: DIN terminal (Without connector) G: Grommet (Lead wire length: 300 mm) H: Grommet (Lead wire length: 600 mm) For the connector part number, refer to page 4-5-10.
Series Variations Model Bearing Bore size Stroke [mm] Cushion Piston speed Port size Mounting direction JMGP 12 (10 x 2) 10, 20, 30, 50, 100 M3 x 0.5 16 (12 x 2) 20 (16 x 2) 20, 30, 50, 100, 150 M5 x 0.8 25 (20 x 2) 50 to 300 mm/s Top 32 (25 x 2) Rubber bumper on both ends Slide bearing Bottom 40 (32 x 2) 1/8 (Rc, NPT, G) 50 (40 x 2) Rear 25, 50, 100, 150, 200 63 (45 x 2) 80 (56 x 2) 50 to
Table 8-1 Quality criteria for clean water (tap water) Item Unit Criterion Circulating fluid Facility water pH (at 25 oC) 6.0 to 8.0 6.5 to 8.2 Electric conductance (at 25 oC) [S/cm] 100 to 300 100 to 800 Chloride ion [mg/L] 50 or less 200 or less Standard Sulfuric acid ion [mg/L] 50 or less 200 or less item Acid consumption (at pH 4.8) [mg/L] 50 or less 100 or less Total hardness [mg/L]
ANR: 20C atmospheric pressure, relative humidity 65% 200 300 , 0.2 AMC-EL3 BE30 1,000 1 4 3 8 1 4 , 3 4 1 2 0.12 AMC-EL2 BE20 0.5 AMC-EL5 BE50 5-10-11 12 Series AMC Flow Characteristics (Initial conditions) Construction/Dimensions Male thread Inlet pressure (MPa) (3 equipartions of circumference) Bracket Port size Air flow (l/min (ANR)) R, NPT, G How to read the graph: If the AMC510 is operated
300 200 200 100 100 1 0 1 2 3 4 5 6 7 Fully opened 0 0 1 2 3 4 5 6 7 8 9 10 Without restrictor Without restrictor Number of restrictors needle rotations Fully opened Number of restrictors needle rotations Restrictor: ASN2-M5 Pressure: 0.5 MPa Mounting orientation: Horizontal, No-load, Piston extended The above piston speed is for reference purpose only.
Rated voltage G: Grommet (Lead wire length: 300 mm) D: DIN terminal DO: DIN terminal H: Grommet (Lead wire length: 600 mm) 50 60 1 2 3 100 VAC, Hz 200 VAC, Hz 110 VAC, Hz 220 VAC, Hz 24 VDC 12 VDC 240 VAC, Hz Other (Without connector) 50 60 50 60 50 60 4 5 6 7 50 60 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside
/80 1600/80 2400/130 XLD-80 XLD-100 XLD-160 AC90240V XLA25-60S-3 XLA25-60S-2 XLA25-60S-2 1 2 3 H4 AC100V 600/150 800/220 1200/350 / AC200V 2400/150 3200/220 4800/350 XLA25-60S-2 XLA25-60S-2 XLA25-60S-2 2 3 4 H5 AC100V 800/180 1200/300 1600/400 / AC200V 3200/180 4800/300 6400/400 1 PTC 200V PTC 200 150 100V PTC 0 5 10 15 20 25 30 ( 30 10 XL-OMY0002 . 1 S 12
(mm) Stroke range A Bore size (mm) P AL B1 B C D FX FD FT GA GB H H1 I J K KA M MM S ZZ NA 20 1/8 18 15.5 13 50 16.5 8 36 5.5 6 18 12 35 5 31 M4 x 0.7 5 6 3 M8 x 1.25 83 124 29 to 200 25 1/8 22 19.5 17 50 18.5 10 36 5.5 6 18 12 40 6 33 M5 x 0.8 5.5 8 3.5 M10 x 1.25 83 129 29 to 300 32 1/8 22 19.5 17 50 20 12 38 6.6 6 18 12 40 6 38 M5 x 0.8 5.5 10 3.5 M10 x 1.25 85 131 35.5 to 300 40 1/8 30
100 50 20 1 Low 1 Fluid indicator Water, Coolant (water-soluble), Cleaning fluid Equivalent to honey Coolant (oil-based) 100 200 300 400 500 FGF1 Paint 300 600 900 1200 1500 FGF3 35 58 85 90 95 100 Flow coefficient (%) 500 1000 1500 2000 2500 FGF5 These relationships between fluids and kinematic viscosity are for guideline purposes only.
Impact acceleration [m/s] 5 0 50 100 150 200 250 300 Speed [mm/s] Relationship between speed and impact acceleration Features 1 in vacuum environments (1.3 x 10-Pa) Carefully designed for low particulate generation, low leakage, and low outgassing.
SCFM Flow Length of Run Feet Compressor HP 25 50 75 100 150 200 300 500 100 6 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4 1 18 1/2 1/2 1/2 3/4 3/4 3/4 3/4 1 1 3 30 3/4 3/4 3/4 3/4 1 1 1 1-1/4 1-1/4 5 45 3/4 3/4 1 1 1 1 1-1/4 1-1/4 1-1/4 7-1/2 60 3/4 1 1 1 1-1/4 1-1/4 1-1/4 1-1/2 1-1/2 10 90 1 1 1-1/4 1-1/4 1-1/4 1-1/4 1-1/2 1-1/2 2 15 120 1 1-1/4 1-1/4 1-1/4 1-1/2 1-1/2 1-1/2 2 2 20 150 1-1/4 1-1
SCFM Flow Length of Run Feet Compressor HP 25 50 75 100 150 200 300 500 100 6 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4 1 18 1/2 1/2 1/2 3/4 3/4 3/4 3/4 1 1 3 30 3/4 3/4 3/4 3/4 1 1 1 1-1/4 1-1/4 5 45 3/4 3/4 1 1 1 1 1-1/4 1-1/4 1-1/4 7-1/2 60 3/4 1 1 1 1-1/4 1-1/4 1-1/4 1-1/2 1-1/2 10 90 1 1 1-1/4 1-1/4 1-1/4 1-1/4 1-1/2 1-1/2 2 15 120 1 1-1/4 1-1/4 1-1/4 1-1/2 1-1/2 1-1/2 2 2 20 150 1-1/4 1-1
Lead wire length Series 300 mm 600 mm 1000 mm 1500 mm 3000 mm Nil L1 L2 L3 L4 20 30 40 Class 2 Class 3 Class 4 Clip Voltage Electrical entry 1 2 3 4 36 100 VAC 200 VAC 110 VAC 220 VAC 230 VAC G C T Grommet Conduit Conduit terminal Flat head screwdriver Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800