SMC Corporation of America
Elite Part Number Search
Search Results "S070M-VDC-40"

-T PNP (2 outputs) + Analog voltage output -T/-V PNP (2 outputs) + Auto-shift input Brown DC (+) Brown DC (+) Brown DC (+) Gray Analog output Gray Auto-shift input Gray Analog output Main circuit Main circuit Main circuit Main circuit Load Load + + + Black OUT1 Black OUT1 12 to 24 VDC Load 12 to 24 VDC Load 12 to 24 VDC Black OUT1 Black OUT1 White OUT2 Black OUT1 White OUT2 Black OUT1

is not provided for the 12 VDC specification.

12 VDC 230 VAC All types equipped with surge voltage suppressor.

voltage: 1 V or less (Load current at 40 mA) Maximum applied voltage: 26.4 VDC Maximum load current: 40 mA Residual voltage: 1V or less (Load current at 40 mA) Output signal Error signal Maintenance signal Effective static neutralization distance 20 mm to 500 mm Ambient temperature During operation/storage 0 to 55 oC Ambient humidity During operation/storage 35 to 65% Rh (With no condensation

. 9-5 9.1.6 HRLE090-W-40. 9-6 9.2 REFRIGERANT AND GWP VALUE . 9-7 9.3 DIMENSIONS . 9-8 9.3.1 HRLE050-A-20. 9-8 9.3.2 HRLE050-W-20. 9-9 9.3.3 HRLE090-A-20/40. 9-10 9.3.4 HRLE090-W-20/40. 9-11 9.4 FLOW DIAGRAM . 9-12 9.4.1 HRLE050-A-20-*,HRLE090-A-20/40. 9-12 9.4.2 HRLE050-W-20-*,HRLE090-W-20/40. 9-12 9.5 COOLING CAPACITY . 9-13 9.5.1 HRLE050-A-20. 9-13 9.5.2 HRLE050-W-20. 9-13 9.5.3 HRLE090

6 12 VDC V 6 VDC S 5 VDC R 3 VDC * DC specification of type D and DO is only available with 12 and 24 VDC.

Cable colour: Signal Cable O.D. 6 mm 1 Brown: 24 VDC (For control) Nominal cross section AWG22 2 White : 24 VDC (For solenoid valve) Wire diameter (Including insulator) 1.5 mm 3 Blue : 0 V (For control) Min. bending radius (Fixed) 40 mm 4 Black : 0 V (For solenoid valve) 5 Gray : Not connected -42No.EX-OMP0013-E (2) Cable with power supply connector (SPEEDCON) Part number: PCA-140180 4 Cable

Electrical entry direction In-line Wiring type 2-wire 3-wire NPN PNP Output type Applicable load IC circuit, relay, and PLC 24 VDC relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 V) Current consumption 10 mA or less Load voltage 24 VDC (10 to 28 VDC) 28 VDC or less Load current 2.5 to 40 mA 40 mA or less Internal voltage drop 4 V or less 0.8 V or less at 10 mA (2V or less at

6 12 VDC V 6 VDC S 5 VDC R 3 VDC F G Supply valve/Release valve combination Pilot valve J K Supply valve Nil DC: 1 W (With indicator light: 1.5 W) AC Supply valve and release valve A Supply valve (N.O.)

22 2.3 33 (8.5) 50 4 x 5.5 8 x 4.5 22 50 4 x 7 <36 40 84 40 36 22 40 5 36 7 4 x 5.5 8 x 4.5 22 14 20 60 70 12 1.6 Working Principle When the input signal rises, the air supply solenoid valve q turns ON, and the exhaust solenoid valve w turns OFF.

Min. to Max. 1,000 L/min 10 to 1000 10 to 1050 Flow rate 2,000 L/min 20 to 2000 20 to 2100 Temperature 50 oC 0 to 50.0 -10.0 to 60.0 Pressure 1 MPa 0 to 1.000 -0.050 to 1.050 Accumulated flow 9,999,999,990 L 0 to 9,999,999,990 0 to 9,999,999,990 PD value Measured object Range Rated range Display/settable range A to B C to D 1,000 L/min 40 to 4000 40 to 4200 Flow rate 2,000 L/min 40 to 4000

RS (D) 32/40/50-L RS (D) 32/40/50-B RS (D) 32/40/50-C RS (D) 32/40/50-D RS (D) 32/40/50-E Mounting base 4. When using a stopper cylinder for intermediate stopping of a load connected directly to a cylinder, etc. The operating ranges shown in this catalog apply only for stopping of a pallet on a conveyor.

D-R732C R73C Relay 24 VDC 5 to 40 mA PLC Relay 24 V AC/DC or less 50mA D-R801 D-R802 R80 PLC 48V AC/DC 40mA D-R8 IC circuit 100V AC/DC 20mA D-R801C D-R802C R80C Relay 24V AC/DC 50mA PLC D-S7 D-S791 D-S792 S79 28 VDC or less 40mA or less Relay D-S7P1 D-S7P2 S7P 80mA or less PLC D-S9 D-S991 D-S992 S99V S99 28 VDC or less 40mA or less IC circuit D-S9P1 D-S9P2 S9PV S9P 80mA or less D-T7 D-T791

Ambient temperature is over 40 . Lower the ambient temperature of servo motor. the servo motor is over 40 . Ambient temperature is 40 Check 2). or less. 2) Servo motor is Check the effective load ratio. The effective load ratio is too high. Reduce the load or take heat dissipation measures. overheated.

Electrical entry Grommet Power supply voltage 12 to 24 VDC Current consumption 40 mA or less Output specification NPN open collector 2 outputs PNP open collector 2 outputs Load voltage 28 VDC or less Impact resistance 980 m/s2 Insulation resistance 50 M or more (500 VDC measured via megohmmeter) between lead wire and case Withstand voltage 1000 VAC for 1 minute (between lead wire and case

pressure 80 80 40 Suction flow (l/min(ANR)) Air consumption (l/min(ANR)) 1 2 3 4 5 6 7 8 Left Right Vacuum pressure (kPa) Vacuum pressure (kPa) 70 ZA1071-K15L-FP1-M2 ZA1051-Q15L-FB-M1 ZA-BP1 60 60 30 Vacuum (V) port 50 40 40 20 Air consumption 30 20 20 Suction flow 10 10 0 0.6 0.4 0.2 0.5 0.3 0.1 0 8 6 4 2 Suction flow (l/min(ANR)) Supply pressure (MPa) 851 Series ZA Specifications General

(C) Correction factor 1.25 IDG 2 to 25 30 32 35 40 2 to 25 30 32 35 40 2 to 25 30 32 35 40 2 to 25 30 32 35 40 1.04 1.05 1.11 AMG 1.04 1 1 1 1 AFF 0.96 0.95 0.90 0.93 0.9 0.90 0.63 0.84 AM Data C: Outlet Air Pressure Dew Point Data D: Inlet Air Pressure AMD Series IDF IDF1E to 75E Inlet air pressure (MPa) Series IDU IDU3E to 37E Inlet air pressure (MPa) Series IDF IDF1E to 75E, 120D to 240D

Step motor (servo/24 VDC) and servo motor (24 VDC) specifications with the following model number are not compliant with UL Standards: Controller/Driver type: Without controller/driver (Nil). Individual actuators are not certified as UL Standards compliant products. 7.

Specifications Series JSXFAE/F 06 10 14 Orifice diameter [mm] 32 40 50 Port size 3/4 1 1 1/2 Fluid Air Pilot valve Exhaust Pilot piping Orifice diameter: 5 mm or larger Min. operating pressure differential [MPa] 0.1 JSXFA Pilot port Max. operating pressure differential [MPa] 0.9 Max. system pressure [MPa] 0.9 Fluid temperature [C] 40*1 to 60 Ambient temperature [C] 40 to 60 Weight [g] Compression