Series VXZ22/23 How to Order Model Port size (Rc 1/4) (Rc 3/8) (Rc 1/2) (Rc 3/4) (Rc 1) 02 03 04 06 10 2230 2230 2240 2350 2360 Electrical option Nil None With surge voltage suppressor With indicator light With light/surge voltage suppressor Thread type S Nil Rc L T NPTF F G Z N NPT Refer to the table (1) given below for availability. VXZ 2230 02 1 G N.C.

L ZY O L ZF G H F ZP K J SP ZCUK B C E D I A 2 x 4.5 AMJ AMV AEP HEP Related Equipment A B C D E F G H I J K L Model ZFC050-02 ZFC050-23 ZFC050-04 ZFC051-01 ZFC051-03 58.5 12.75 12.75 2 3.2 33 25 10 10.5 10.5 12 8.5 13.75 4 58 12.5 12.5 1/8" 5/32" ZFC100-04 4 ZFC100-06 6 30 10 18 11.6 19.5 23 20 29 53.2 9.1 14.1 ZFC101-03 5/32" ZFC101-07 1/4" ZFC200-06 6 ZFC200-08 8 34 14 22 15.6 23.1 27

tP3100 0 Travel Angle Indicator 0 not irrcludsd '1 included Thread Size Nil Rc(pt) 1/4 N femals 1/4 NPT NOTE: 1.

Relation of Operating Temperature and Maximum Operating Pressure Particulate Generation Grade Classifications 1.2 10 Average particle concentration Particles/ft Grade 4 Max. operating pressure MPa 1.0 10 0.8 Grade 3 10 0.6 10 Grade 2 10 0.4 Grade 1 100.2 0 5 0 20 40 60 1 0.1 0.2 Particle size m or less 0.3 0.5 Operating temperature C 1 Series AS-FPQ/FPG How to Order AS 2 1 1 2 F P Q 01 06

Nil F Note 1) Thread type (2) G Pressure gauge ARX20N Rc NPT G Nil N F ARX21N P Port size Panel nut 01 02 1/8 1/4 Option combination numbers Panel nut is also included with B.

Basic style CG1BN32SCG132, #1 CG1BN40SCG140, #1 CG1BN50SCG150, #1 CG1BN63SCG163, #1 CG1BN80SCG180, #1 CG1BN100SCG1100, #1 CG1BN20SCG120, #1 CG1BN25SCG125, #1 TA/TB cross section With rod boot (mm) (mm) Bore (mm) Bore (mm) Built-in One-touch fitting Air-hydro JH IJ h f TG TDH9 TE TF e JW ZZ TC l +0.08 0 +0.08 0 +0.08 0 +0.08 0 +0.08 0 +0.08 0 20 25 32 40 50 63 80 100 20 25 32 40 50 63 80 100

Bar length (mm) IZS31-E3 IZS31-E3 IZS31-E4 IZS31-E5 1 300 30 1 380 1 1 620 80 1 1 780 L 1 3 1100 3 1 1260 2 2 1500 Part no L 5 1 1900 IZS31-E3 IZS31-E4 IZS31-E5 200 4 2 2300 280 360 The model number requires the suffix -X14 to indicate that the body is to be shipped fitted with a security cover. IZS31 Standard part no.

lock nut J Nil Lock nut option Body size AS-F AS-F 2 3 4 1/8, 1/4 standard 3/8 standard 1/2 standard Made to Order TMH X260 Antistatic type Refer to page 635 for details.

Made to Order Body size 100 200 205 300 400 M3, M5 standard 1/8 standard 1/4 standard 3/8 standard 1/2 standard Grease-free (Sealant: Fluoro coated) + Restrictor (Without Check Valve) -X21 Metric size 02 23 04 06 08 10 12 Inch size 01 03 07 09 11 13 Lock nut option 1/8" 5/32" 1/4" 5/16" 3/8" 1/2" 2 3.2 Ex.)

VER2000 Repeatability 3% F .S. Sensitivity 0.5% F .S. 1.5% F .S. Linearity 3% F .S. Lubrication Not required (Use turbine oil Class 1, ISO VG32 if lubricated.)

Local Area: (800) 258-9200-www.stevenengineering.com G 1/2 5-1 1/4, 1 1/2 Conduit terminal:VP4270T12 14 DIN terminal: VK4270D12 14 G 1/2 Applicable cable O.D. 6 to 12 G 1/2 3-6-8 9 Series VP450 Manifold Specifications How to Order VVP4 1 04 04 0 5 VK Thread type Series VP 5 port solenoid valve Manifold Nil Rc VZ G F N NPT Base size NPTF T VF Common EXH 5 6 3 4 A/B Port size 1 VFR Symbol

Port size AMD550 AMD650 AMD850 01 B 06 10 14 B 3 4 1B 1 8 N.C. auto-drain N.O. auto-drain Drain guide Accessory 02 03 B 1 4 B 3 8 04 B 1 2 1 B 1 2 20 2B 1 4 B IN-OUT reversal direction T Element service indicator Option AMD800 to AMD1000 Self-standing type AMD801/901 Piping support type 20 01 AMD 8 20 00 AMD 8 Port size Body size Port size Body size 8 8 20 2B flange 30 3B flange 20 2B flange

, 290 80 AM350 3 4 2B/FF/10K 11/2 B/FF/10K 1 2 3 4 , 305 312 80 AM450 AMl 1 1 1 2 1 3 4 1 2 , , , 339 80 AM550 Related poroducts 391 80 AM650 1 2 1 540.5 80 AM850 Precautions/With Differential Pressure Gauge(GD40-20-01) Be sure to read before handling.

370 440 100 120 130 160 180 210 246 290 ITVX 1 4, 3 8, 1 2 1 4, 3 8, 1 2 1 2, 3 4 1 2, 3 4 PVQ 3 4, 1 3 4, 1 VY1 Adapter Assembly Installation Procedure Accessory/Compact Pressure Switch: IS10-01 For details, refer to Best Pneumatics No. 8.

8 10 10 12 12 01 1/8" 03 5/32" 07 1/4" 09 5/16" 11 3/8" 13 1/2" -X214 Restrictor (Without check valve) With One-touch fittings Example) AS2002FS-04-X214 With indicator 10Clean Series 1 For selecting applicable tubing O.D., refer to the Model shown above. 2 Use 1/8" tubing.

Operating Pressure Particulate Generation Grade Classifications 1.2 104 Average particle concentration Particles/ft3 Max. operating pressure MPa Grade 4 1.0 103 0.8 Grade 3 102 0.6 101 Grade 2 100 0.4 Grade 1 10-1 0.2 0 5 0 20 40 60 1 0.1 0.2 Particle size m or less 0.3 0.5 Operating temperature C 15-17-3 4 Series AS-FPQ/FPG How to Order AS 2 1 1 2 F P Q 01 06 Body size 1 2 3 4 M5 standard

Series: 250 [3 Port COM (Single Unit)], Voltage: 12VDC, Electrical Entry: Grommet / Tape winding, Orifice: 1 [250 (3 Port) ø1], Port Size: 01 [1/8 (6A)], Thread: Rc, Material: Stainless Steel Body, NBR Seal Class B Coil, Option: -, CE Compliance: -