End Plate Assembly > q U end plate assembly no.
(mm) 2(A) Port size R(PT) 2(A) Port size R(PT) 1(P) 1(P) 1(P) 4 6 8 10 12 M5 1 8 1 4 3 8 1 2 1 8 1 4 3 8 1 2 4 6 8 10 12 1(P) M5 M5 4 M5 4 Tube O.D. (mm) Tube O.D.
Align the ejector assemblies r, end block (R) w, and end block (L) e using positioning pins (at the two a positions) and fasten with a hexagon socket head cap bolts q (2 pcs.) (with a tightening torque of 0.6 Nm0.06 Nm). XT53440 05 Number of stations 05 06 12 1 station 2 station 8 station 13-9-10
A part z1 m1 = 20 x 3 x 4 x 2.7 x 10-6 = 6.48 x 10-4 (kg) Weight calculation m1 = a x b x c x Relative density IZ1 Inertial moment around Z1 axis IZ1 = {m1 (a2 + b2) / 12} x 10-6 = {6.48 x 10-4 x (202 + 32)/12} x 10-6 = 2.21 x 10-8 (kg.m2) = 2.21 x 10-8 + 6.48 x 10-4 x 16.42 x 10-6 = 0.20 x 10-6 (kg.m2) IA Inertial moment around Z axis IA =IZ1 + m1r12 x 10-6 z f2 z2 B part r2 = 23.5(mm)
A part z1 m1 = 20 x 3 x 4 x 2.7 x 10-6 = 6.48 x 10-4 (kg) Weight calculation m1 = a x b x c x Relative density IZ1 Inertial moment around Z1 axis IZ1 = {m1 (a2 + b2) / 12} x 10-6 = {6.48 x 10-4 x (202 + 32)/12} x 10-6 = 2.21 x 10-8 (kg.m2) = 2.21 x 10-8 + 6.48 x 10-4 x 16.42 x 10-6 = 0.20 x 10-6 (kg.m2) IA Inertial moment around Z axis IA =IZ1 + m1r12 x 10-6 z f2 z2 B part r2 = 23.5(mm)
Inlet air pressure [MPa] Inlet air temperature [C] Allowable pressure drop P [MPa] Compressed air supply capacity Q [l/min (ANR)] Note: F = (C x 1.8) + 32 1MPa = 145psi 1l/min = 0.0353SCFM Dew point temperature conversion chart 60 0.5MPa 0.7MPa 0.9MPa 50 0.3MPa 40 Atmospheric pressure 0.1MPa Pressurized dew point temperature C 30 20 10 0 10 20 30 40 50 60 50 60 20 10 0 10 20 30 40 30 Atmospheric
D-M9W 10 2 pcs. D-M9WV D-M9AV 5 Note 2) 1 pc. 10 2 pcs. 5 Note 2) 1 pc. D-M9A 10 Note 2) 2 pcs. 5 1 pc. D-M9V 5 2 pcs. 5 1 pc. D-A9V 10 2 pcs. 5 1 pc. D-A9 10 2 pcs. 1 pc. 15 D-P3DWA 2 pcs. 15 Note 1) Confirm that it is possible to secure the minimum bending radius of 10 mm of the auto switch lead wire before use.
15 ZPR40D 40 43 29 42.5 53.3 71.1 25 97 87 17 15 A P P L I C A B L E T U B E A P P L I C A B L E T U B E Applicable Tube OD P Q R S Applicable Tube OD P Q R S 4 4 23.3 15.8 10.4 6 6 24.3 16.8 12.8 H O W T O O R D E R Z P R P A D H O R I Z O N T A L T Y P E W I T H O U T B U F F E R 6 6 24.3 16.8 12.8 8 8 26.2 18.7 15.2 8 8 26.2 18.7 15.2 ZPR P A D D I A M E T E R 02 2 04 4 06 6 08 8 10 10
Bore size B DA DB DL DU DC DX DE DO DR DT DS DH Z DD H10 32 219 40 237 50 268 63 280 80 351 100 371 MB-B03 32 46 42 32 22 10 44 14 62 9 6.6 15 7 33 213 10+0.058 0 40 52 42 32 22 10 44 14 62 9 6.6 15 7 33 231 10+0.058 0 MB-B05 50 65 53 43 30 11.5 60 20 81 10.5 9 18 8 45 260 14+0.070 0 63 75 53 43 30 11.5 60 20 81 10.5 9 18 8 45 272 14+0.070 0 MB-B08 80 95 73 64 45 14 86 30 111 12.5 11 22 10
14 Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) 20 12 12 10,11 10, 11, 12 08, 09 1000 10 15 8 500 06, 07 10 6 500 4 5 2 0 0 5 10 0 5 10 0 Number of needle rotations Number of needle rotations 15-9-53 12 Series ASD-FG Construction ASD230FG ASD330FG/430FG ASD530FG/630FG ASD530FG-02 @1 !
: 10 or more The mean q Non-unidirectional airflow: at least two locations NL = A x 64/(10M) 0.5 q Number of sampling locations: 2 to 9 95% UCL of the mean and the mean of the averages w Number of sampling locations: 1, or 10 or more The mean Derive it from the area of the cleanroom or clean air controlled space.
NBR FKM KA00809 KA00725 Quantity 1 1 1A-P85 4D-P85 FNR100N-10 1.1 L Rc1 Stainless steel 304 FNR100V-10 FNR101N-10 FNR101V-10 Model Tank capacity Port size 1.8 L KA00809 4 O-ring Industrial Filters Replacement Procedure Actuators Modular F.R.L.
NBR FKM KA00809 KA00725 Quantity 1 1 1A-P85 4D-P85 FNR100N-10 1.1 L Rc1 Stainless steel 304 FNR100V-10 FNR101N-10 FNR101V-10 Model Tank capacity Port size 1.8 L KA00809 4 O-ring Industrial Filters Replacement Procedure Actuators Modular F.R.L.
-X Technical Data 1501 A CY1S Series Construction CY1S/Bilateral piping type For 6 #8 For 6 For 10 23a 29a o !5 !1 @4 !2 !3 @1 !8 !7 !6 $4 !9 @0 @7 @2 #1 r q w e y t i u !5 !1 !4 #2 #0 !
level: 1 Air flow level: 1 10 10 10 10 Air flow level: 10 5 Air flow level: 10 5 Air flow level: 10 Air flow level: 10 5 5 Air flow level: 10 Air flow level: 10 5 5 0 0 0 200 400 600 800 1000 1200 1400 1600 0 200 400 600 800 1000 1200 1400 1600 0 0 0 0 Installation distance [mm] 0 200 400 600 800 1000 1200 1400 1600 0 200 400 600 800 1000 1200 1400 1600 Installation distance [mm] 0 200 400
set unit Note 1) Accumulated pulse flow rate exchange value (Pulse width: 50 ms) Note 1) 0.1 l/pulse 0.5 l/pulse 1 l/pulse 2 l/pulse 5 l/pulse l/min, CFM x 10-2 l, ft3 x 10-2 l/min, CFM x 10-1 l, ft3 x 10-1 Display units Real-time flow rate Accumulated flow Note 1, 2) 0 to 9 l, 0 to 9 ft3 x 10-2 0 to 9 l, 0 to 9 ft3 x 10-1 Accumulated flow range Note 1) Power supply voltage Current consumption
They can be ordered in multiples of 10 pieces.
F F 1 2 1 2 MHL2-10DZ MHL2-16DZ MHL2-16D Z MHL2-10D Z 60 60 25 25 Pressure 0.6 MPa Gripping force [N] Gripping force [N] Gripping force [N] Gripping force [N] Pressure 0.6 MPa 50 50 20 20 Pressure 0.6 MPa 0.5 MPa Pressure 0.6 MPa 0.5 MPa 40 40 15 15 0.4 MPa 0.5 MPa 0.5 MPa 0.4 MPa 0.4 MPa 30 30 0.4 MPa 10 10 0.3 MPa 20 20 0.3 MPa 0.3 MPa 0.3 MPa 0.2 MPa 5 5 10 10 0.2 MPa 0.2 MPa 0.2 MPa 10
14 20 10 20 10 (All dimensions but A and CL are identical to those of the basic style.)
VXF(A)2160 Tank 41l 6 x 10 pcs. VXF(A)2160 Tank 41l 6 x 6 pcs. 10 x 12 pcs. 10 x 12 pcs. Without tube (VXF2280) Without tube Without tube (VXF2280) Flow rate Q (Nl) 10 x 12 pcs. 10 x 8 pcs. 10 x 12 pcs. 10 x 8 pcs. VXF(A)2280 Tank 70l 10 x 8 pcs. VXF(A)2280 Tank 70l 10 x 8 pcs. 10 x 10 pcs. 10 x 10 pcs. 100 mm 100 mm 10 x 10 pcs. 10 x 10 pcs. 10 x 8 pcs. 10 x 8 pcs.