SMC Corporation of America
Elite Part Number Search
Search Results "VV317-02-031-02N-A-Q"

S kit is composed of a flat cable housing assembly (AXT100-2-PS20) of q SI unit and w P kit (20 pins).

Lube Unit/ALDU600-06 to 10, ALDU900-12 to 20 Float switch mounting position Mounting thread M12 R 3.2 S 40 Q IN P M N M L A B C E E F G K J (Bracket mounting dimensions) H D S Bracket (Option) Panel (Option) 6 x 17 A B C D E F G H J K L M N P Q R S Model Port size ALDU600-06 ALDU600-10 ALDU900-12 ALDU900-14 ALDU900-20 289 291.2 453 453 476 24.5 13.6 51 45.5 14.5 69.5 78.2 89 94.5 102.5 4

It is illustrated with an arrow pointing away from the valve body or a "filled" triangle on the schematic. f INLET E OUTLET Mounting hole Outlet (Downstream) Bottom port (Upstream) Inlet (Upstream) Porting Symbols Top view (Mounting hole on bottom) 2PW 2PWA 2PWB 2PWC q q q w 2 Ports 3 Ports 4 Ports q w w w 3PWD 3PWE 3PWG 3PWH 3PWF 3PWJ q q q q q q e e e e e e w w w w w w 4PWK 4PWL 4PWM 4PWN

[100 VAC specification] Power cable (Length: approx. 1.9 m) Dimensions [mm] Model Port size A B C D E F G H J K L M N P Q IDU3E Rc3/8 15 IDU4E Rc1/2 483 568 355 300 13 IDU6E Rc3/4 485 15 455 498 283 275 270 31 42 80 230 32 15 240 80 284 Refrigerant R407C (HFC) IDF D IDU8E to IDU15E1 D E A B Q Illuminated switch Evaporation thermometer Ventilation air outlet Refrigerant R134a (HFC) IDU E

It is illustrated with an arrow pointing away from the valve body or a "filled" triangle on the schematic. f INLET E OUTLET Mounting hole Outlet (Downstream) Bottom port (Upstream) Inlet (Upstream) Porting Symbols Top view (Mounting hole on bottom) 2PW 2PWA 2PWB 2PWC q q q w 2 Ports 3 Ports 4 Ports q w w w 3PWD 3PWE 3PWG 3PWH 3PWF 3PWJ q q q q q q e e e e e e w w w w w w 4PWK 4PWL 4PWM 4PWN

Signal 1 Pitch Magnetic section Non-magnetic section 0.2 0.1 0.3 Movement A phase B phase Signal 2 q A scale of magnetic layers and non-magnetic layers with a pitch of 0.8mm is cut into the piston rod. w With movement of the piston rod, a sin, cos 2-phase signal (Signal 1) is received by the magnetic resistance element.

Note 3) D-A9 and D-A9V auto switches cannot be used with the product with a bore size of 12 (CE112). Port side A, B, C Auto switch mounting rail side only q BQ-2 w BQ2-012 Two kinds of auto switch mounting brackets are used as a set. q BQ-1 w BQ2-012 Two kinds of auto switch mounting brackets are used as a set.

K F 10 AW B 30 03 BG JN K F 21 AW B 30 03 BG JN Copper, fluorine and silicone-free + Low particle generation q r t y w e Filter regulator Option/Semi-standard: Select one each for a to g.

(Use an auto switch rated 24V DC, with a minimum amperage capacity of 10mA.) q q q w w w e e e r (Unit: N) Bore size (mm) 40 50 63 80 100 Operation r Min. sensing weight 26 40 62 100 160 Warning Back-up of the balance pressure data The balance pressure data is backed up by the controller for approximately 5 minutes during a power outage or when the power supply has been turned OFF.

Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Warning: Danger : Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.

-15A VNH3 -20A VNH4 -25A A B A B A B A B 60 80 100 115 217 (219) 246.5 (248.5) 282 (284) 301 (303) 60 77 96 113 46 60 76 85 34 40 50 60 24 36 41 50 135 164.5 200 219 50 60 79 90 77 1 8 1 2 3 x 3 4 3 x 1 1 4 95.5 111 119 VNH VNH 1 4 VND Note) ( ): CE-compliant product (-Q) VCC Model J K L M N O P Q R S T U VNH1 -10A A B VNH2 -15A A B VNH3 -20A A B VNH4 -25A A B M5 x 0.8 depth 5.5 M6 x 1 depth

Construction L-Bracket w e r t w e r t q Component Parts No. Description Material 1 Bracket Steel strip DIN Rail Mounting Bracket q o !0 !1 i y u q o !0 !1 i y q w e Component Parts No. Description Material Note 1 Body A PBT 2 Knob POM 3 Body B PBT 4 Needle PBT 5 Needle guide Brass Electroless nickel plating 6 U-seal HNBR 7 Spacer PBT1 Component Parts No.

4 q !3 !3 !6 !6 t t Component Parts !1 No. Description Material 1 Bracket Steel strip !1 DIN Rail Mounting Bracket q w e q o !0 i y u q o !0 i y Component Parts No. Description Material Note 1 Body A PBT 2 Knob POM 3 Body B PBT 4 Needle PBT 5 Needle guide Stainless steel 6 U-seal HNBR 7 Spacer PBT1 Component Parts No.

Proper auto switch mounting positions (Series CE1) (mm) Bore size (mm) Auto switch model Symbol 20 32 40 50 63 12 A B A B A B A B A B A B A B A B A B 40.5 47 55 79 82 85.5 D-A7, A8 4 13 17 39 44 41.5 Contact protection box internal circuits 41 47.5 55.5 79.5 82.5 86 D-A7H, A80H, A73C, A80C, D-F7, J79, F7V, J79C 4.5 13.5 17.5 39.5 44.5 42 Choke coil OUT Brown [Red] CD-P11 38 44.5 52.5 76.5

8 q !1 A B A' B' Without magnet Extension locking u t @5 @0 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com When shipped Section A-A' Retraction locking !0 !5 Section B-B' !3 !

Actuation Warning 1 Normally closed q Cannot be used for vacuum retention. w Use a release valve. (Without a release valve, the workpiece may not be released.)

10-/21-AR20-B30-B: Max. 3.5 10-/21-AW40-B: Max. 5 AR50-B/60-B 10212 x P1 (Port size) A BB Pressure gauge (Option) C H K IN OUT B Q AA Applicable tubing 6/4 P2 (Pressure gauge port size) R F J M D J U Bracket (Option) T N S Optional specifications Standard specifications Model Round type pressure gauge Bracket mounting size Panel mount P1 P2 A B Note 1) C D Q R S T U V W Y Z F J K AA BB H

Then, screw in q from the top of the housing w to tighten it. Note ) Tighten within the tightening torque of 0.5 Nm 20%. Changing the entry direction The orientation of a connector can be changed 180, depending on the combination of a housing w and a terminal block e. 1.

This produces an air cushion cylinder which retains the merits of a compact design. Nearly three times the allowable kinetic energy Interchangeable mounting The mounting dimension "M" is the same as the compact cylinder Series CQS/CQ2. Working principle A + A' A' q When the piston is retracting, exhaust is discharged from both A and A' until piston seal H passes the air passage A.