SMC Corporation of America
Elite Part Number Search
Search Results "VV5FA3-30-121-00T"

and main valve Lubrication Mounting orientation Not required Unrestricted Note 2) Shock/Vibration resistance (m/s2) 150/30 Dustproof ( M8 connector conforms to IP65.)

and main valve Lubrication Mounting orientation Not required Unrestricted Note 2) Shock/Vibration resistance (m/s2) 150/30 Dust proof ( M8 connector conforms to IP65.)

Tighten the mounting screws evenly. -10No.D-S-OMU0002-A Wiring SIO mode NPN output PNP output Brown (No.1) Brown (No.1) Load Black (No.4) Main circuit Black (No.4) Main circuit White (No.2) Power supply 15 to 30 VDC Load White (No.2) Power supply 15 to 30 VDC Load Load Blue (No.3) Blue (No.3) Connector pin numbers shown in brackets.

AXT661-12A Nil 300 mm 600 mm 1000 mm 2000 mm 3000 mm 6 10 20 30 Plug connector lead wire length Passage Indicator light Single Latching type A-C ON (Set) Indicator light Passage The lead wire length of the valve with lead wire is 300 mm.

20, 25, 32 5, 10, 15, 20, 25, 30, 40, 50 TN TF R Rod piping/ Pad direct mounting 32 32 mm Note) In the case of rod piping (Q, R), TF (G1/8) is not available.

Substitute 11.7 J for E and 0.3 for . 30.7 36.8 43.0 67.5 73.6 92.0 153 J 38.5 46.2 53.9 84.7 92.4 115 192 Substitute both absorbed energy E and collision speed for Data A in order to calculate the corresponding weight of the impacting object. 50.3 60.3 70.4 111 121 151 251 Me 260 kg D63.6 76.3 89.1 140 153 191 318 7.

SX3000-77-1A SX5000-77-1A SX3000 SX5000 51 80.8 97 26 mm2 SX5000 (10) 30 mm2 1-6-85 Manifold Option D-sub connector (25 pins)/Cable assembly D-sub Connector Cable Assembly Terminal No. AXT100-DS25015 030 050 L Terminal no.

AXT661-12A Nil 300 mm 600 mm 1000 mm 2000 mm 3000 mm 6 10 20 30 Plug connector lead wire length Passage Indicator light Single Latching type A-C ON (Set) Indicator light Passage The lead wire length of the valve with lead wire is 300 mm.

AXT661-12A Nil 300 mm 600 mm 1000 mm 2000 mm 3000 mm 6 10 20 30 Plug connector lead wire length Passage Indicator light Single Latching type A-C ON (Set) Indicator light Passage The lead wire length of the valve with lead wire is 300 mm.

Body size 10 20 30 40 50 60 AV Thread type AU Metric thread (M5) Rc NPT G Nil AF N F AL20 Port size AR Body size Symbol Port size M5 1/8 1/4 3/8 1/2 3/4 1 10 20 30 40 50 60 (2) IR M5 01 02 03 04 06 10 Accessory When more than one specification is required, indicate in alphanumeric order. Note 2) For M5 and NPT thread types.

Standard specifications AL30 AL40 AL60 AL10 AL40-06 AL20 AL50 Model Port sizes 1/4, 3/8 1/4, 3/8, 1/2 1 M5 x 0.8 3/4 1/8, 1/4 3/4, 1 Fluid Air Proof pressure 1.5MPa Maximum operating pressure 1.0MPa 1/4: 30 3/8: 40 1/2: 50 Note 1) 1/4: 30 3/8: 40 220 4 50 15 190 Minimum dripping flow rate [L/min (ANR)] Oil capacity (cm3) 55 135 7 135 25 135 135 Recommended lubricant Class 1 turbine oil (ISO

56 82 102 152 208 274 8000 4 26 50 76 93 137 188 245 10 3 21 45 70 89 125 172 222 12000 17 41 65 84 118 155 210 16000 9 34 57 75 110 142 188 HOW TO USE THIS TABLE 20 8 28 52 68 103 136 172 30 5 12 39 55 87 120 156 40 11 22 43 74 108 142 1 From Stroke Factors Table (see Table 1 on page 21), 50 9 15 30 66 96 130 determine the value of L. 60 14 18 57 88 119 2 In the left table, locate the previously

56 82 102 152 208 274 8000 4 26 50 76 93 137 188 245 10 3 21 45 70 89 125 172 222 12000 17 41 65 84 118 155 210 16000 9 34 57 75 110 142 188 HOW TO USE THIS TABLE 20 8 28 52 68 103 136 172 30 5 12 39 55 87 120 156 40 11 22 43 74 108 142 1 From Stroke Factors Table (see Table 1 on page 21), 50 9 15 30 66 96 130 determine the value of L. 60 14 18 57 88 119 2 In the left table, locate the previously

Substitute 11.7 J for E and 0.3 for . 30.7 36.8 43.0 67.5 73.6 92.0 153 J 38.5 46.2 53.9 84.7 92.4 115 192 Substitute both absorbed energy E and collision speed for Data A in order to calculate the corresponding weight of the impacting object. 50.3 60.3 70.4 111 121 151 251 Me 260 kg D63.6 76.3 89.1 140 153 191 318 7.

AXT661-12A AXT661-14A AXT661-14A-6 AXT661-14A-10 AXT661-14A-20 AXT661-14A-30 Lead wire length Single/3 position No. AXT661-12A AXT661-14AN AXT661-14AN-6 AXT661-14AN-10 AXT661-14AN-20 AXT661-14AN-30 Double No.

Socket only (3 pcs.) 300A 600A 1000A 2000A 3000A AXT661-13A AXT661-13A-6 AXT661-13A-10 AXT661-13A-20 AXT661-13A-30 AXT661-13AN AXT661-13AN-6 AXT661-13AN-10 AXT661-13AN-20 AXT661-13AN-30 AXT661-14AN AXT661-14AN-6 AXT661-14AN-10 AXT661-14AN-20 AXT661-14AN-30 100/110 VAC for single: AXT661-31A-; for double: AXT661-32A200/220 VAC for single: AXT661-34A-; for double: AXT661-35Aare in accordance

No.1 OFF ON P2 No.2 OFF ON P3 No.3 OFF ON P4 No.4 OFF ON P5 P6 P7 P8 7 8 1 2 3 4 5 6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 50 13 14 15 16 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 51 F : 2019 1 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +

Supply 15 to 30 VDC to the power supply for communication. Check the power supply for communication voltage.