Data Clevis Pin, Knuckle Pin Rod End Nut l Bore size (mm) Bore size (mm) l d B Dd9 H L C D d Part no.
Protrusion of Auto Switch from Edge of Body (L) Misc.
point distance (L = 35 mm) and the pressure (0.6 MPa).
A22 Symbol: A23 Symbol: A24 30 30 DA L RD MM 30 MM DA 30 MM MM DB DB T T C B A H AL H A L K H A A W H H Symbol: A25 Symbol: A26 Symbol: A27 Symbol: A28 Symbol: A29 DA 30 MM MM DA 30 DA 30 30 MM L W MM A L H AL H LB K A AL A H L A H T AL L K H MM Symbol: A30 30 MM W A T H 84 Simple Specials Series CP96/C96 Symbol Change of Trunnion Bracket Mounting Position 2 -XC14 Series C85 Series
through Q R E GB GA 4-NN MM D CB CA C K J JA E H A' A 2-P through KA B 4-T counterbore Width across flats L S + Stroke Z + Stroke (mm) Port size Bore size (mm) GA H J JA A B A' C CA CB D E GB 20 25 32 29 32.5 35 19 23 27 16 20 24 12 15 19 26 32 40 42 50 62 20 25 31 22 25 31 9 10 11 27 22.5 25 14 18 22 12 15.5 19.5 8 10 12 M5 x 0.8 M5 x 0.8 Rc 1/8 Bore size (mm) NN T S Z K KA L MM P Q R Standard
Stroke 16 CXSJ10P 0.3 14.4 0.3 41.4 Stroke (64.5 + Stroke) 56 + Stroke 8.5 44.5 + Stroke 7.5 8 + Stroke 16 4-M1.6 x 0.35 x 8 L 20 2-M5 x 0.8 thread depth 4 (Piping port) OUT IN Steel balls 8-28-25 25 Series CXSJ Dimensions: 15 to 32 Standard Piping U Q R T ZZ + Stroke Stroke J K SS + Stroke 1 D B M L Z I 1 G 0.2 (G) H A E F (Through) N ( I ) (L) (Z) (G) C NN A B ZZ C D E M F G H I J K L
L) (Z) (G) C NN A B ZZ C D E M F G H I J K L N NN Q R U 2-M5 x 0.8 thread depth 4 2-M5 x 0.8 thread depth 4 2-M5 x 0.8 thread depth 4 2-Rc 1/8 thread depth 5 SS T Bore size (mm) 2 x 2-4.3 through 2 x 2-8 counterbore with depth 4.3 2 x 2-5.5 through 2 x 2-9.5 counterbore with depth 5.3 2 x 2-6.5 through 2 x 2-11 counterbore with depth 6.3 2 x 2-6.5 through 2 x 2-11 counterbore with depth 6.3
through Q R E GB GA 4-NN MM D CB CA C K J JA E H A' A 2-P through KA B 4-T counterbore Width across flats L S + Stroke Z + Stroke (mm) Port size Bore size (mm) GA H J JA A B A' C CA CB D E GB 20 25 32 29 32.5 35 19 23 27 16 20 24 12 15 19 26 32 40 42 50 62 20 25 31 22 25 31 9 10 11 27 22.5 25 14 18 22 12 15.5 19.5 8 10 12 M5 x 0.8 M5 x 0.8 Rc 1/8 Bore size (mm) NN T S Z K KA L MM P Q R Standard
MXF Calculation of resistance force f MXW San 1 (L/GP)2 (provided that L>GP) MXP Calculation of theoretical output F MG L (mm) W MGP Refer to the table of theoretical output on p.3.8-3.
ported Body ported Base mounted Base mounted (With sub-plate) VZA212-P-M5 M5 x 0.8 0.13 0.35 0.52 0.15 0.43 0.60 N.C.
If there is vibration, impact, etc. at long stroke, we recommend adoption of side support even if it is within the allowable value shown in the graph. (1500) 400 W L Load W ML2B32 ML2B32 W (1200) 300 ML2B25 ML2B25 L L 200 100 0 1000 2000 Support spacing L (mm) 718 ML2B Series Auto Switch Mounting Auto Switch Proper Mounting Position (Detection at Stroke End) Operating Range (mm) Auto switch
-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VX3 L L VXA K VN K Conduit terminal: T LVC LVA F (Q) 34 LVH LVD LVQ 25 U LQ R C LVN G1/2 TI/ TIL E B A H D 2-P Port size (S) PA 2-M Thread depth N PAX L PB K (mm) Electrical entry P Port size B C A D E F H K L M N Grommet:G Conduit:C Conduit terminal:T Model Q R Q R Q R S U 13.5 28 64 1/8 31 6.5
= 43 A P = 43 PA 23 A A B B 14 12 A PA PA L1 L2 L2 L1 B B B 14 12 A A A A B 14 A A PA B B (2n 1/8) 4n-1/4, 3/8 2, 4 port PA L-side R-side L-side R-side D-side D-side 89 3 89 16 141 (Single) 141 (Single) 55 44 186 (Double) 186 (Double) 196 (3 position) 196 (3 position) 77.5 Bottom ported M12 connector L: Dimensions n: Stations 141.5 L n 1 Formula 2 3 4 5 6 7 8 9 10 121 5 1 12 14 PA PB 107
r w AR30(K)-B/AR40(K)-B q t AR50(K)-B/AR60(K)-B e IN OUT q t r w e IN OUT r w Component Parts No.
S T V W X Y ZZ LD 20 25 121 5.5 40 55 M8 x 1.25 17 15 1/8 81 9.5 4.5 6.5 20 9 151 7 25 28 121 5.5 40 55 M10 x 1.25 17 15 1/8 81 11 3.5 5.5 20 9 156 7 32 30 133 6 45 60 M14 x 1.5 18 15 1/8 87 13 3 4 23 9 172 7 40 35 158 6 55 75 M16 x 1.5 22 21 1/4 108 16 5 0 25 11 198 9 6 Series CHN Dimensions Front flange type: CHNF Width across flats B2 Rc P Rc P GA2 Cushion valve GB1 NN GB2 T V Rc P MM
environment specification L is not available for the IR1000 series.
How to find the flow rate for air/ Flow rate formulas based on the air temperature of 20C For subsonic range where P + 0.1013 < 1.89 (P + 0.1013) Q = 226S P(P + 0.1013) For sonic range where P + 0.1013 1.89 (P + 0.1013) Q = 113S (P + 0.1013) Q : Flow rate [l/min(ANR)] S : Effective area (mm) P : Pressure drop P P (MPa) P: Upstream pressure (MPa) P: Downstream pressure (MPa) How to make
Power consumption P: 20 [kW] Q = P = 20 [kW] Cooling capacity = Considering a safety factor of 20%, 20 [kW] x 1.2 = V: Power supply voltage P 24 [kW] Power consumption e Derive the heat generation amount from the output. Output (shaft power, etc.) W: 13 [kW] w Derive the heat generation amount from the power supply output.
B + Stroke L K A + Stroke 2 x 4-M6 x 1.0 effective depth 10 M W Rod end male threads H1 Rod end nut C1 X L1 Rod end male threads mm Bore size (mm) C1 X H1 L1 20 25 18.5 12 14 M8 x 1.25 22.5 15 17.5 M10 x 1.25 Standard type mm A B C D E E1 E2 F H K L M Q W Bore size (mm) 20 25 Stroke range (mm) 15 to 50 36.5 32 7 10 36 18 21 15.5 M5 x 0.8 8 4.5 25.5 21 39 15 to 50 41.5 36.5 12 12 40 20 23.5
Hydraulic fluid Compatibility Standard mineral hydraulic fluid Compatible W/O hydraulic fluid Compatible JIS symbol O/W hydraulic fluid Compatible Not compatible Water/Glycol hydraulic fluid Phosphate hydraulic fluid Contact P/A.