per minute 1 60 = x x Reference life cycles Cycles per minute 1 8 (daily operating time) Service life 1 60 = 1 8 50,000,000 50 x x 2083 days = 27 Process Pump Common Precautions 5 Be sure to read before handling.

7.5 39.5 M3 x 0.5 External pilot port (External pilot type) 5.2 2 x M5 x 0.8 5(R1) port 7.5 Manual override 2 x M5 x 0.8 1(P) port 68.5 (Double solenoid dual 3-port) 68.5 (Double solenoid dual 3-port) 48.2 (Single solenoid) 48.2 (Single solenoid) 4.1 5 (With barb fittings) 34 2 x 4.5 Mounting hole 76.5 (Closed center) 76.5 (Closed center) R1 5 R2 3 X (31) 16.3 28.7 P 1 6.8 P 1 22.8 17.2

Load factor: ( (Load weight x 9.8) /Theoretical force) x 100% Conditions Series CJ2 Series CM2 6 x 1 m AS3301F-06 8 x 1 m AS3301F-08 AN110-01 Series MB/CA2 Series CJ2 Series CM2 4 x 1 m Series MB/CA2 Body ported Tubing bore x Length Speed controller Silencer Base mounted Tubing bore x Length Speed controller Silencer AS2301F-04 6 x 1 m 4 x 1 m AS1301F-04 AN120-M5 SYJ5120-M5 SYJ5140-01 AN101

1 2 stns. + 3 stns. 2 stns. + 3 stns. x 2 2 stns. x 2 3 stns. x 2 2 stns. x 2 + 3 stns. x 2 2 stns. x 2 + 3 stns. 2 stns. x 1 3 stns. x 3 Note) Manifold bases are composed by connecting 2 station and 3 station bases.

1 3 stns. x 1 2 stns. x 2 3 stns. x 2 3 stns. x 3 2 stns. x 2 + 3 stns. 2 stns. + 3 stns. 2 stns. + 3 stns. x 2 2 stns. x 2 + 3 stns. x 2 Note) Manifold bases are composed by connecting 2 station and 3 station bases.

1 3 stns. x 1 2 stns. x 2 3 stns. x 2 3 stns. x 3 2 stns. x 2 + 3 stns. 2 stns. + 3 stns. 2 stns. + 3 stns. x 2 2 stns. x 2 + 3 stns. x 2 Note) Manifold bases are composed by connecting 2 station and 3 station bases.

1 2 stns. + 3 stns. 2 stns. + 3 stns. x 2 2 stns. x 2 3 stns. x 2 2 stns. x 2 + 3 stns. x 2 2 stns. x 2 + 3 stns. 2 stns. x 1 3 stns. x 3 Note) Manifold bases are composed by connecting 2 station and 3 station bases.

0.5 M5 x 0.8 0.39 0.10 0.59 [0.40] 0.43 [0.33] 0.16 [0.11] 0.36 54 (28) 3 position 0.42 [0.33] 0.16 [0.080] 0.46 0.32 0.11 0.58 [0.32] 22 25 2 position SYJA320-M3 M3 x 0.5 M3 x 0.5 0.9 28 3 position 22 25 2 position SYJA330 M3 x 0.5 Note 1) Value when used on a manifold.

) [ ] lamp Lights up when AL.01 Tank level drop failure or AL.02 Tank level dropalarm is generated.

Panel adapter B ZS-22-02 Thread type Piping port size Rc NPT G Nil N F 01 02 1/8 1/4 Specifications PFA301-m PFA300-m Model Specifications Note 1) 1 to 10, 5 to 50l/min (0.04 to 0.35, 0.18 to 1.77SCFM) Flow rate range measurement & setting Minimum setting unit 1% of maximum flow rate range Model PFA510-m PFA550-m Real-time flow rate l/min, CFM x 10-2 Display units Measured fluids Dry air,

120 PA, B: 13.5 (0.75) [7 (0.39)] A, BR1, R2: 7 (0.39) 3 position pressure center SYJA7520-01 Base mounted 01 02 01 02 01 02 01 02 12.6 (0.7) 170 (90) 2 position single SYJA714012.6 (0.7) 190 (110) 2 position double SYJA72408.5 (0.47) 3 position closed cente SYJA7340(1) M5 X 0.8 200 (120) 1/8, 1/4 9 (0.5) [6.5 (0.36)] 3 position exhaust center SYJA7440PA, B: 13.5 (0.75) [7 (0.39)] A, BR1

192 3 stns. x 1 2 stns. x 2 3 stns. x 2 2 stns. + 3 stns. x 2 2 stns. x 1 3 stns. x 3 2 stns. + 3 stns. 2 stns. x 2 + 3 stns. 2 stns. x 2 + 3 stns. x 2 Manifold composition Note) Manifold bases are composed by connecting 2 station and 3 station bases.

192 3 stns. x 1 2 stns. x 2 3 stns. x 2 2 stns. + 3 stns. x 2 2 stns. x 1 3 stns. x 3 2 stns. + 3 stns. 2 stns. x 2 + 3 stns. 2 stns. x 2 + 3 stns. x 2 Manifold composition Note) Manifold bases are composed by connecting 2 station and 3 station bases.

side (FD) 12 Base Mounted Type Series VQ5000 Dimensions (mm) 1in 25.4mm Bottom port diagram With connector on U side (FU) 106 46.8 59.2 83.5 9 9 55.5 M5 ground screw 2n-1/2 (ports A, B) 34.5 n U side X 12 B 2 A 4 6 B A B 2 A 4 5 SMC SMC SMC SMC SMC B A B 2 A 4 4 B A P=41 L1 L2 B 2 A 4 3 B A B 2 A 4 2 B A 34.5 46 68.5 P = 41 B 2 A 4 1 B A 58.5 X 12 Stations 2-1/8 (external pilot port) 15.5

) [ ] lamp Lights up when AL.01 Tank level drop failure or AL.02 Tank level dropalarm is generated.

Table 1.1-3 Communication mode and product functions DIO SERIAL Simple communication LOCAL DIO DIO REMOTE MODBUS protocol pattern LOCAL 1 2 Run timer x x x Stop timer x x x Recovery from power cut x x x Anti-freezing Pump accumulated operating time reset x x x Warming up function Snow coverage protect function*2 2: This function cannot be set on the products of the cooling method

Table 1.1-3 Communication mode and product functions DIO SERIAL Simple communication LOCAL DIO DIO REMOTE MODBUS protocol pattern LOCAL 1 2 Run timer x x x Stop timer x x x Recovery from power cut x x x Anti-freezing Pump accumulated operating time reset x x x Warming up function Snow coverage protect function*2 2: This function cannot be set on the products of the cooling method

Rated Sensitivity Rated current voltage x size voltage of leak (A) [V] current [mA] 1-phase 100, HRR010-A/W-10100V AC(50/60Hz) 115 15 115V AC(60Hz) 3 cores x 14AWG (3 cores x 30 2.0mm2) (including 1-phase ground) 200, HRR010-A/W-20230 10 200-230V AC (50/60Hz) Installation/operation in accordance with the UL standard For the product operation in the UL compliant conditions, the conditions

Seals Body(plate) material : PEEK Diaphragm material : EPDM Variations 2 Port 3 Port LVM200 LVM100 LVM20 LVM10 Effective area mm2 (Cv) 1.8(0.1) 0.63(0.035) 1.8(0.1) 0.72(0.04) Orifice size 2 1.4 2 1.5 Port size M6 M5 M5 M6 Applicable tube 6 x 4 4 x 2.5 N.C. (Normaly closed) O O O O N.O.