Pressure Range: ISE76G (0 to 5 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: M (SI Unit Only)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: M5 (Female Thread)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8)
Rated Flow Range: 21 (2 to 200 L/min), Flow Adjustment Valve: W (With Flow Adjustment Valve, Rear Ported), Port Size: C8 (ø8), Output Specification: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: M (SI Unit Only)
Output Specification: SV (2 outputs, NPN/PNP switching type + Analog current output), Unit Specification: M (Fixed SI Unit), Option 1 (Lead Wire): L (Power supply/output connection lead wire, Lead wire length: 2 m), Option 2 (Mounting): B (Panel Mount Adapter)
Output Specification: SV (2 outputs, NPN/PNP switching type + Analog current output), Unit Specification: M (Fixed SI Unit), Option 1 (Lead Wire): L (Power supply/output connection lead wire, Lead wire length: 2 m), Option 2 (Mounting): B (Panel Mount Adapter), Option 3 (Sensor Connector): None, Option 4 (Manual or Certificate): Y (w/o Operation Manual or Calibration Certificate)
Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 12 (1 1/4), Output Specification: C (OUT1: NPN; OUT2: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)
DIGITAL FLOW MONITOR. O20. 64.00000 lb. MONITOR, DIGITAL FLOW.
Input Specifications: 0 (Voltage Input), Output Specification: SV [2 Outputs (NPN/PNP Switching Type) + Analog Current Output], Unit Specification: M (SI Unit Only), Lead Wire: L (Power Supply/Output Connection Lead Wire, 2m), Bracket/Panel Mount: A1 (Bracket A, Vertical Mounting), Sensor Connector: C (Sensor Connector, for PF2MC and PF3A7)
Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8)
Rated Flow Range: 501 (5 to 500 L/min), Thread Type: Rc, Port Size: 04 (1/2), Output Specifications: A (Out 1: NPN; Out 2: NPN), Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: M (SI Unit Only)
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 10 (1), Output Specification: K (OUT 1: Analog 4 to 20mA; OUT 2: Analog 4 to 20mA), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: 02 [R1/4, (M5, Female Threaded)]
Model: 7 (VP700), Pilot: Internal Pilot, Pressure Specifications: K (High Pressure (1.0MPa)), Rated Voltage: 5 (24 VDC), Electrical Entry: DZ (DIN terminal with connector, with light/surge voltage suppressor), Safety limit switch/Wiring: M (M12 connector, made by OMRON), Flow Direction: Nil (left to right), No. of Residual Pressure Exhaust Valves: S (Single), Soft Start-up: S (with Soft Start
Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8)
Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: C8 (ø8), Output Specification: L2 (Out 1: IO-Link or NPN/PNP, Out 2: NPN, PNP, or Input), Lead Wire: N (w/o Lead Wire w/Connector), Unit Specification: M (SI Unit Only)
Rated Flow Range: 21 (2 to 200 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: 02 (Rc1/4), Output Specification: C (Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only)
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter
Output Specification: SV (2 outputs, NPN/PNP switching type + Analog current output), Unit Specification: M (Fixed SI Unit), Option 1 (Lead Wire): L (Power supply/output connection lead wire, Lead wire length: 2 m), Option 2 (Mounting): A1 (Bracket A, Vertical Mounting), Option 3 (Sensor Connector): C (With Sensor Connector)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: M (SI Unit Only), Piping Specification: M5 (Female Thread)