Recommened tightening torque for pressure regulator: R 1/8 = 7 to 9 N.m, R 1/4 = 12 to 14 N.m Note 7) Piping adapter, O-ring, Hexagon socket bolt, Hexagon socket bolt assembly. These are shipped together with products. in the gauge part number indicates thread type. Specify no symbol for RC, N for NPT, and G for F.
Air dryer model IDF100FS-30-R IDF125FS-30-R IDF150FS-30-R Breaker capacity 20 A 30 A Sensitivity current: 30 mA Corrosion is not covered under warranty. Option symbol V With a timer controlled solenoid valve type auto drain Option symbol Float type heavy duty auto drain is changed to the solenoid valve type auto drain.
(mm) 4 6 8 10 12 (1) AS221FE-01 AS231FE-01 20, 25, 32 R 1/8 AS221FE-02 AS231FE-02 20, 25, 32, 40 R 1/4 AS321FE-03 AS331FE-03 40, 50, 63 R 3/8 AS421FE-04 AS431FE-04 63, 80, 100 R 1/2 Note 1) Elbow type only Note 2) Distinction between meter-out/meter-in types by appearance Those are distinguished by the lock nut.
(mm) Applicable cylinder bore size (mm) 4 6 8 10 12 AS-FPG AS-FPQ Clean performance Resin: PP Metal: Brass (electroless nickel plated) Resin: PP Metal: Stainless steel 304 M5 x 0.8 6, 10, 16, 20 AS121FP-M5 R 1/8 20, 25, 32 AS221FP-01 R 1/4 20, 25, 32, 40 AS221FP-02 R 3/8 40, 50, 63 AS321FP-03 10-AS-F 10-AS-FG R 1/2 63, 80, 100 AS421FP-04 Resin: PBT, POM Metal: Brass (electroless nickel plated
MLGC Taper ring Steel ball CNG P q MNB f CNA R R CNS CLS CLQ MLGP RLQ MLU ML1C Manual override for unlocking DEven if the air supply is blocked or exhausted, lock release is possible. The fail safe mechanism locks again when the manual override is released.
9 @0 @1 @2 @3 @4 Material Description Spring washer Set screw Rod end nut Wear ring Cushion seal Rod seal Piston seal Cushion valve seal Cylinder tube gasket Piston gasket Magnet No. q w e r t y u i o !0 !1 !2 !
Assembly 1) Terminal block e connected with housing r should be reinstated.
First characteristic numeral First Characteristics: Degrees of protection against solid foreign objects Non-protected 0 Protected against solid foreign objects of 50 mm and greater 1 Voltage drops at the value of x r.
8 q #8 $1 y Single acting, Spring extend (TL, TM) Double acting with spring (BL, BM) r $0 !1 !2 #7 #4 #7 @2 e #5 #3 @8 #7 #7 #1 @8 w 10-9-6 6 Heavy Duty Stopper Cylinder Series RSH/RS1H Construction Component Parts (For single acting) No.
0 @1 r ye t !4 !7 !3 wu !8 @0 @2 @3 !6 q !5 !9 i *1 *1 C95K32 A A-A A !2 !
1 o q $8 y $1 r #5 B A CL CL1 MLGC @3 !4 %0 !3 #9 @8 #6 $0 w #0 $5 $7 $3 $9 %1 $4 @1 @4 !8 @0 !7 !
Data L R S Piping Port Locaition Nil Operating direction Left Right L R S a b h g d c f e Note) Plugs are installed in ports other than those indicated for the model. Applicable Auto Switch/Refer to page 8-30-1 for further information on auto switches.
1 $1 #0 r MY2H16 MY2HT16 $5 !4 @5 !9 @3 !5 #1 @4 $4 !2 $3 #3 #5 #6 @0 #4 #7 !7 #2 @6 @7 Component Parts Note No.
Flow Switch Type: 5 (Remote Sensor Unit), Rated Flow Range: 40 (5~40L/min), Return Unit: None, Thread: N (NPT), Port Size: 06 (3/4), Flow Switch Output: 2T (Remote Sensor Unit; Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None, Temp. Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (without Lead Wire), Flow Switch Unit: G (Remote Sensor Unit; Instantaneous Flow: L/min, (gal/min);
Flow Switch Type: Remote Sensor Unit, Rated Flow Range: 5~40L/min, Return Unit: None, Thread: NPT, Port Size: 3/4, Flow Switch Output: Remote Sensor Unit; Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None, Temp. Analog 4 to 20 mA; Temperature Sensor: Yes, Lead Wire: without Lead Wire, Flow Switch Unit: Remote Sensor Unit; Instantaneous Flow: L/min, (gal/min); Accumulated Flow: None; Temp:
This combination Filter/ Regulator minimizes space and piping by integrating the 2 units into one. Standard features include a relieving regulator, which can be quickly locked by pushing down on the adjustment knob. There are many options, which include gauges, auto-drain, metal bowl and covers, different set pressures, etc. The AW is part of the family of modular air preparation
VALVE, SOFT START 3/4, ModelPort sizeProof pressureOperating pressure rangePressure gauge port sizeAmbient and fluid temperatureEffective area (mm2)Mass (kg)Electrical specificationsPilot valve manual override1(P) 2(A)2(A) 3(R)Rated coil voltageAllowable voltage fluctuationCoil insulation typeApparent power AC(Current consumption)Current consumption DCElectrical entryOption specificationsAV50003
Series AMH is a high precision, micro-mist separator combined with a prefilter. The AMH can separate and eliminate aerosol state oil mist in compressed air and remove carbon or dust of more than 0.01micron. The AMH series is suitable for drying/cleaning pneumatic measurement instruments (air micrometer) and precision parts.Micro mist separator w/prefilter, Modular connection is possible
to 60C, Electrical entry: grommet, type D DIN connector, type Y DIN connector, VALVE, SOFT START 3/4, VALVE, AV SOFT START UP BODY PORT, KA, AV BODY PORT 3/4 NPT, 3.61558 lb, ModelPort sizeProof pressureOperating pressure rangePressure gauge port sizeAmbient and fluid temperatureEffective area (mm2)Mass (kg)Electrical specificationsPilot valve manual override1(P) 2(A)2(A) 3(R)