Pressure Range: -100.0 to 100kPa, Piping Specifications: M5 Female Thread/Side Piping Port, Output Specifications: PNP Open Collector 2 Outputs, Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: No Lead Wire, Adapter: R [DIN Rail Adapter (DIN Rail to be Prepared by Customer)], Calibration Certificate: -
Pressure Range: 0.0 to -101.0kPa, Piping Specifications: M5 Female Thread/Side Piping Port, Output Specifications: PNP Open Collector 2 Outputs, Unit Specifications: Fixed SI Unit, kPa, Lead Wire: No Lead Wire, Adapter: Panel Mount Adapter+Front Protective Cover, Calibration Certificate: -
Pressure Range: 0.0 to -101.0kPa, Piping Specifications: M5 Female Thread/Side Piping Port, Output Specifications: PNP Open Collector 2 Outputs, Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: No Lead Wire, Adapter: Panel Mount Adapter+Front Protective Cover, Calibration Certificate: -
Pressure Range: 0.0 to -101.0kPa, Piping Specifications: M5 Female Thread/Side Piping Port, Output Specifications: PNP Open Collector 2 Outputs, Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: R [DIN Rail Adapter (DIN Rail to be Prepared by Customer)], Calibration Certificate:
Pressure Range: 0.0 to -101.0kPa, Piping Specifications: M5 Female Thread/Side Piping Port, Output Specifications: PNP Open Collector 2 Outputs, Unit Specifications: Fixed SI Unit, kPa, Lead Wire: No Lead Wire, Adapter: R [DIN Rail Adapter (DIN Rail to be Prepared by Customer)], Calibration Certificate: -
Pressure Range: 0.0 to -101.0kPa, Piping Specifications: M5 Female Thread/Side Piping Port, Output Specifications: PNP Open Collector 2 Outputs, Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: Panel Mount Adapter+Front Protective Cover, Calibration Certificate: w/Certificate
Pressure Range: -100.0 to 100kPa, Piping Specifications: M5 Female Thread/Side Piping Port, Output Specifications: PNP Open Collector 2 Outputs, Unit Specifications: Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan, Lead Wire: No Lead Wire, Adapter: None, Calibration Certificate: w/Certificate
Pressure Range: -100.0 to 100kPa, Piping Specifications: M5 Female Thread/Side Piping Port, Output Specifications: PNP Open Collector 2 Outputs, Unit Specifications: Fixed SI Unit, kPa, Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: Panel Mount Adapter+Front Protective Cover, Calibration Certificate: -
Pressure Range: -100.0 to 100kPa, Piping Specifications: M5 Female Thread/Side Piping Port, Output Specifications: PNP Open Collector 2 Outputs, Unit Specifications: Fixed SI Unit, kPa, Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: R [DIN Rail Adapter (DIN Rail to be Prepared by Customer)], Calibration Certificate: w/Certificate
Pressure Range: 0.0 to -101.0kPa, Piping Specifications: M5 Female Thread/Side Piping Port, Output Specifications: PNP Open Collector 2 Outputs, Unit Specifications: Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan, Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: Panel Mount Adapter+Front Protective Cover, Calibration Certificate
Pressure Range: -100.0 to 100kPa, Piping Specifications: M5 Female Thread/Side Piping Port, Output Specifications: PNP Open Collector 2 Outputs, Unit Specifications: Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan, Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: Panel Mount Adapter+Front Protective Cover, Calibration Certificate
Pressure Range: -100.0 to 100kPa, Piping Specifications: M5 Female Thread/Side Piping Port, Output Specifications: PNP Open Collector 2 Outputs, Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: R [DIN Rail Adapter (DIN Rail to be Prepared by Customer)], Calibration Certificate:
ZSE10 compact, digital pressure switch for vacuum/compound pressure has been reduced in height by approximately 50% when compared to the ZSE30A. Up to 10 slave sensors can be set at once using the copy settings function. Options include direct mount, panel mount or DIN rail mount, and a choice of 2 piping directions., N, ZSE10, "VACUUM SWITCH, N lb
SMC has improved product performance and reliability with the redesigned SY series valve. The SY3000 and SY5000 have the same valve width as their predecessors, but the flow has been increased by up to 80%, allowing the valve size to be reduced. A built-in strainer in the pilot valve prevents trouble caused by foreign matter. By using H-NBR seal material for the main valve and seals, Ozone
Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: w/o Lead Wire, Bracket: B (Panel Mount Adapter)
Series: -, Actuation: -, Mounting/Porting: -, Seal: -, Pilot Specification: -, Back Pressure Check Valve: -, Pilot Valve: -, Coil Specification: -, Voltage: -, Light/Surge Suppressor/Common Specification: -, Manual Override: -, A,B Port Size: -, Thread: -, Mounting Option: -
Series: -, Actuation: -, Mounting/Porting: -, Seal: -, Pilot Specification: -, Back Pressure Check Valve: -, Pilot Valve: -, Coil Specification: -, Voltage: -, Light/Surge Suppressor/Common Specification: -, Manual Override: -, A,B Port Size: -, Thread: -, Mounting Option: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: w/o Lead Wire, Bracket: B (Panel Mount Adapter)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: w/o Lead Wire, Bracket: B (Panel Mount Adapter)
Dimensions Meter-out type Meter-in type F E D B A C J G K H L B Model A MIN. MAX. MIN. MAX.