Auto Switch Specifications Grommet PLC: Programmable Logic Controller D-G5NT (With indicator light) With built-in OFF-delay timer (approx. 200 ms) Easy intermediate detection D-G5NT Auto switch model Wiring type 3-wire Output type NPN Output operation Off-delay Operating time 1 ms or less 200 50 ms Off-delay time Applicable load IC circuit, Relay, PLC Power supply voltage 5, 12, 24 VDC

Selects the time for filtering. 1.0 ms 2: 10 ms 3: 20 ms 0: 1.0ms 4 Digital Input Extension Time 1: 15 ms Sets the time to hold the input signal per unit. Selects the time to hold the input signal. 15 ms 2: 100 ms 3: 200 ms 1: True (Auto) Error is automatically cleared when the short circuit is fixed.

or less (With anti-chattering function: 24 ms, 192 ms and 768 ms selections) Yes 3 1/2 digit LED display (Sampling cycle: 5 times/sec.)

Auto Switch Specifications Grommet With built-in OFF-delay timer (200 ms) PLC: Abbreviation of Programmable Logic Controller D-G5NTL (With indicator light) CJ1 D-G5NTL Auto switch model Wiring type 3-wire CJP Output type NPN Output operation Off-delay CJ2 Operating time 1 ms or less Off-delay time 200 50 ms CM2 Applicable load IC circuit, Relay, PLC CG1 Power supply voltage 5, 12, 24 VDC

For LECSB, set [ms/div] and [Number of collection Div] to the horizontal axis (time axis). [ms/div] [Number of collection Div] will be [Measurement time]. Click of [ms/div] and set the DiV number. The unit ms of [Number of collection Div] is 1000ms1s.

Response time settings: 20 ms, 160 ms, 640 ms, 1280 ms This function averages pressure values measured during the response time set by the user and then compares the average pressure value with the pressure set point value to output the result on the switch.

Response time settings: 20 ms, 160 ms, 640 ms, 1280 ms This function averages pressure values measured during the response time set by the user and then compares the average pressure value with the pressure set point value to output the result on the switch.

or longer Max. applied voltage: 28 V, Max. load current: 80 mA, Internal voltage drop: 1 V or less External input: Input voltage 0.4 V or less (Reed or Solid state input) for 30 ms or longer Accumulated pulse output wiring examples PF3A7H--CS/DSPF3A7H--ES/FSMax. 28 V, 80 mA Black OUT Load Brown DC(+) Black OUT Load Max. 80 mA Blue DC() or or 0 V 0 V 50 ms 50 ms 50 ms 50 ms 12 PF3A7H Series

OUT2 setting/(CH1 only) MPa or kPa OUT1 OUT2 CH 1 2 3 4 PRESSURE Normally Open Normally Closed SET SET 16-3-11 11 Series PSE530/200 Operation 1: Initial Setting 4 Response time setting MPa kPa OUT1 OUT2 CH 1 2 3 4 PRESSURE 5 ms 20 ms 160 ms 640 ms SET Press SET button.

Port exhaust 2 Supply valve maintains vacuum by energization (20 ms or more). Stopping the vacuum turns on the release valve.

SY Body width: 9.8 mm C: 0.055 dm3/(sbar)(Standard, high pressure type) C: 0.14 dm3/(sbar) (Large flow type) : Option SYJ ON: 3.5 ms, OFF: 2 ms, Dispension accuracy 1 ms (With light/surge voltage suppressor; supply pressure 0.5 MPa) 200 million cycles or more (Factors determined in a life test by SMC) VK VZ Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370

Speed Vc Acceleration Aa Speed [mm/s] Total travel distance S Time [s] Positioning time Tp LAT3LAT3MLAT3FShortest positioning time [ms] 600 350 700 Shortest positioning time [ms] Shortest positioning time [ms] Load weight1000g Load weight1000g Load weight1000g 300 600 [ms] 500 [ms] [ms] 700g 700g 700g 250 500 400 500g 500g 500g 200 400 300 150 300 200 100 200 300g 300g 300g 100 100g 100g

(mm) 8 2.5 4 5 6.5 H Black (B) TUS related accessories Inner sleeve Series TJ White (W) D Red (R) Blue (BU) MS Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Yellow (Y) Reinforces soft polyuretharane tubing.

Auto Switch Specifications Grommet With built-in OFF-delay timer (200 ms) PLC: Abbreviation of Programmable Logic Controller D-G5NTL (With indicator light) MX D-G5NTL Auto switch model Wiring type 3-wire MTS Output type NPN Output operation Off-delay MY Operating time 1 ms or less Off-delay time 200 50 ms CY Applicable load IC circuit, Relay, PLC MG Power supply voltage 5, 12, 24 VDC (4.5

Auto Switch Specifications Grommet With built-in OFF-delay timer (200 ms) PLC: Abbreviation of Programmable Logic Controller D-G5NTL (With indicator light) MX D-G5NTL Auto switch model Wiring type 3-wire MTS Output type NPN Output operation Off-delay MY Operating time 1 ms or less Off-delay time 200 50 ms CY Applicable load IC circuit, Relay, PLC MG Power supply voltage 5, 12, 24 VDC (4.5

Auto Switch Specifications Grommet With built-in OFF-delay timer (200 ms) PLC: Abbreviation of Programmable Logic Controller D-G5NTL (With indicator light) MX D-G5NTL Auto switch model Wiring type 3-wire MTS Output type NPN Output operation Off-delay MY Operating time 1 ms or less Off-delay time 200 50 ms CY Applicable load IC circuit, Relay, PLC MG Power supply voltage 5, 12, 24 VDC (4.5

Auto Switch Specifications Grommet With built-in OFF-delay timer (200 ms) PLC: Abbreviation of Programmable Logic Controller D-G5NTL (With indicator light) MX D-G5NTL Auto switch model Wiring type 3-wire MTS Output type NPN Output operation Off-delay MY Operating time 1 ms or less Off-delay time 200 50 ms CY Applicable load IC circuit, Relay, PLC MG Power supply voltage 5, 12, 24 VDC (4.5

Metric 1/8" to 1" 1/8" to 1/2" 1/8" to 3/4" 1/8" to 1 1/4" Inch Translucent, Red, Blue, Black Translucent, Red, Blue, Black Translucent Translucent Color KQ2, KQG2, KP, KP KQ2, KQG2, KP, KP One-touch fittings Applicable fitting series M, MS (Hose nipple type) M, MS (Hose nipple type) M, MS (Hose nipple type) Miniature fittings KF, KFG2 KF, KFG2 KF, KFG2 Insert fittings LQ series LQ series

(Coil temperature: 20C, at rated voltage) 10-SY3000 10-SY7000 With light/surge voltage suppressor Response time (ms) (at the pressure of 0.5 MPa) With light/surge voltage suppressor Response time (ms) (at the pressure of 0.5 MPa) Actuation type Without light/surge voltage suppressor 12 or less Actuation type Without light/surge voltage suppressor 31 or less Type R, U Type S, Z 12 or less

It takes 10 [ms] to switch the channel. CH.B Channel 10 [ms] 10 [ms] CH.A Time GND CH.SELECT terminal 10 [ms] 10 [ms] Disconnected Time 16-13-11 19 Technical Information 2-wire pressure switch connections 14 Voltage and current output pressure sensors 15 A 3-wire type switch is a switch that has an output line other than the positive and negative lines that supply the electricity.