Discharge capability 1) Flow-rate characteristics PB1013A Flow-rate characteristics (5Hz) PB1013A flow-rate characteristics (When operated at PB1013A5Hz 5H ) 0.7 Discharge pressure (MPa) 0.6 SUP=0.7MPa 0.5 MPa SUP=0.5MPa 0.4 SUP=0.35MPa 0.3 SUP=0.2MPa 0.2 0.1 0 0 200 400 600 800 1000 Discharge rate (mL/min) mL/min Caution The above flow characteristic graph is for clean water (viscosity
Discharge capability 1) Flow-rate characteristics PB1313A Flow-rate characteristics (5Hz) PB1313A5Hz 0.5 SUP=0.5MPa Discharge pressure (MPa) 0.4 SUP=0.4MPa MPa 0.3 SUP=0.3MPa 0.2 SUP=0.2MPa 0.1 0 0 200 400 600 800 1000 Discharge rate (mL/min) mL/min Caution -The above flow characteristic graph is for clean water (viscosity 1mPas, specific gravity 1.0).
VCC12(D)-00 (2 port valve) VCC13-00 (3 port valve) Full length: 44.8 to 45.1 0.2 Full length: 54.6 to 54.9 0.4 Except face seal (O-ring) Except face seal (O-ring) Tighten the screw until it hits the body by pressing the orifice body with approx. 100 to 200 N of force. ( Additional tightening is not necessary.)
To use the power of the device, the total load current must be 200 mA or less. 2 : Refer to 2.4.2 Contact output signal 4 to 6. 2.2 Communication specification HRL Series 2-2 HRX-OM-W069 Chapter 2 Contact input/output communication /Analog output communication Table 2.2-3 Contact input/output communicatin /Analog output pin number PIN No.
To use the power of the device, the total load current must be 200 mA or less. 2 : Refer to 2.4.2 Contact output signal 4 to 6. 3 : For option D1 CH1 Electric conductivity control, it can be set.
To use the power of the product, the total load current must be 200 mA or less. 2.2 Communication specification HRLE Series 2-2 HRX-OM-Z015 Chapter 2 Contact input / output communication Table 2-4 Contact input/output communication terminal number PIN No.
(No indication on display) Sets target temp. for control. 0.0 to 50.0C (0.1C) 25.0 1.0 to 60.0C (0.1C) 60.0 -9.99 to 9.99C (0.01C) 0.00 -9.9 to 49.0C (0.1C) -9.9 10 to 999% (1%) 200 0.0 to 10.0C (0.1C) 1.5 0.0 to 10.0C (0.1C) 1.5 2 PB Range Sets PB (Proportional Band) range used for PID control. 0.3 to 9.9C (0.1C) 3.0 0.0 to 99.9sec (0.1sec) 0.0 None, Odd, Even None On, Off Off 600, 1200,
(Table 1) Table 1 Example of applicable fitting: Male connector (O-ring parallel thread) (Made by Swegelok) Cylinder Fitting thread size for Example of Piping tube OD (inch) model piping applicable fitting CYV15 5/16-24 UNF SS-200-1-OR 1/8 CYV32 7/16-20 UNF SS-400-1-OR 1/4 2.
How to order 002 FGH 100 03 T Element seal aterial PTFE Nominal filtration accuracy Nominal filtration Applicable Applicable Symbol accuracy Element model Element length 002 2m Filtration Element Applicable 004 4m HEPO FGH100 Symbol efficiency length Element 300 006 6m 99% 100 L117 EJ701S 013 13m 200 L246 EJ801S,ED801S X20 0.2m Filtration FGH200 300 L496 EJ901S,ED901S efficiency Membrane
(Note1) (Petroleum,Water-glycol, Emulsion,Phosphoric ester) Applicable model FH100-06 FH100-08 FH100-10 FH100-12 FH100-16 FH100-20 FH100-24 INOUT Port size (Rc) 3/4B 1B 1 1/4B 1 1/2B 2B 2 1/2B 3B Drain port size M162 Rated flow Paper 50 80 120 160 260 450 600 rate Micromesh 60 100 150 200 300 550 700 (L/min) Operating pressure 1.0MPa Operating temperature 80oC Nominal filtration 1.
Faster Average speed [mm/s] Measuring conditions Supply pressure: 0.55 MPa 0 50 100 150 125-250 160-300 Bore size-Stroke 200-300 250-450 320-530 Speed adjustment rotary switch set value 0 5 9 Mounting: Vertical downward Load: no-load Operating direction: Upward *1 The average speed value is the stroke divided by the full stroke time.
.(-1060 25) CEUL/CSARoHS 01 02 C01 N01 N02 A2 B2 R1/8 M50.8 Rc1/8 NPT1/8 R1/4 NPT1/4 M50.8 URJ1/4 TSJ1/4 M50.8 M50.8 C3604SUS316L PSE563 5.1 3 m 2 0.2 mm 1.12 mm PSE56--28: 2 5.1 3 m 2 0.2 mm 1.12 mm 193 g 200 g 194 g 201 g 187 g 203 g 193 g 101 g 108 g 102 g 109 g 95 g 111 g 101 g -12No.PS-OMG0005CN-E [mA] [V] A B C 0-101 kPa 0 -101 kPa 10.1 kPa -100100 kPa -100 kPa 100 kPa 01 MPa
Series 140 160 180 200 CQ2-Z 7.5 8.0 7.0 7.0 CQM RZQ MK-Z MGP-Z MGZ 2 : The range of operation is a standard including hysteresis, and is not guaranteed. 1: Bore sizes 32 and higher for the MHS series require a separate mounting bracket. (Bracket Part number: BMG2-012) 2: All bore sizes for the MGZ and MHC series require a separate mounting bracket.
This person should also continuously review all specifications of the product referring to its latest catalogue information, with a view to giving due consideration to any possibility of equipment failure when configuring the equipment. 100 0.05 0.09 0.15 0.24 0.39 0.64 1.00 125 0.07 0.11 0.18 0.29 0.47 0.76 1.20 150 0.08 0.13 0.21 0.34 0.54 0.89 1.30 200 0.10 0.17 0.28 0.44 0.70 1.10 1.70
Table 3 Specification-3 Size Weightg Internal capacitycm 90 180 360 90 180 360 10 120 150 200 1.2 2.2 4.3 15 220 270 380 2.9 5.5 10.7 20 600 700 1000 7.1 13.5 26.3 30 900 1100 1510 12.1 22.9 44.7 40 1400 1600 2280 20.5 39 76 -17- 1-2 Effective output Fig.1 Effective output 1-3 Rotation range When pressurized from the Port A, the shaft will rotate clockwise.
. -3- 1Specification High performance Battery-less absolute encoder LESYH*(D,R,L)G* LESYH LESYH LESYH LESYH LESYH LESYH LESYH Model 8*GA 8*GB 8*GC 16*GA 16*GB 25*GA 25*GB Stroke[mm] 50,75 50,100 50,100,150 Max.work load[kg] 2 8 12 Horizontal Vertical 1.5 3 6 6 12 10 20 note1)note3) Pushing Force 18~36 37~74 69~138 70~140 135~270 197~395 382~765 note1)note3) 20~800 10~400 5~200 20800 10400
Lead wire color (grommet) Voltage Color SOL 100 VAC Blue Cylinder Xa Xb Xc Yb Ya Mode 200 VAC Red Upward High speed a DC Red (+), Black () Low speed b Downward High speed c How to use the needle Low speed d Rotate the needle clockwise to close, and counterclockwise to open.
Lead Wire Color (Grommet) Caution Voltage Color 100 VAC Blue 200 VAC Red DC Red (+), Black () Other Gray Electrical Connection DIN terminal is connected inside as in the figure below. Connect to the corresponding power supply. Caution 7 VT317-OMH0002-B Specific Product Precautions (2) Be sure to read this before handling the products. How to wire DIN terminal 1.
Model Allowable pressing load (N) MHM-16D 100 MHM-25D 200 MHM-32D 300 MHM-50D 500 5. Do not apply impact load to the center of the magnetic attraction surface. Otherwise, it may result in a breakage or malfunction. 6. The head cap is magnetized during the release of workpiece. Iron particles may be attracted. 7 - 2-3 Environment Warning 1.
disassembly of the SI unit -24No.EX-OMN0011-F Specifications Specifications General specifications Item Specifications Ambient temperature -10 to +50 oC Ambient humidity 35 to 85%RH (No condensate) Ambient temperature for storage -20 to +60 oC Withstand voltage 500 VAC applied for 1 minute Insulation resistance 500 VDC, 10 M or more Operating atmosphere No corrosive gas Enclosure IP67 Weight 200