Auto Switch Specifications Grommet With built-in OFF-delay timer (200 ms) PLC: Abbreviation of Programmable Logic Controller D-F5NTL (With indicator light) CRB2 D-F5NTL Auto switch model Wiring type 3-wire CRBU2 Output type NPN Output operation Off-delay CRB1 Operating time 1 ms or less Off-delay time 200 50 ms MSU Applicable load IC circuit, Relay, PLC CRJ Power supply voltage 5, 12, 24
Refer to fault SI unit SI unit MS LED is No.1 OFF malfunction Refer to fault SI unit PWR(V) LED No.2 is OFF Yes No Refer to fault SI unit L/A LED is No.3 OFF Refer to fault SI unit MS LED is No.4 red ON Refer to fault SI unit MS LED is No.5 red flashing Refer to fault SI unit MS LED is No.6 green flashing Refer to fault SI unit MS LED is SI unit NS LED is No.7 green ON OFF Refer to fault
Response time Life VQZ1000 10 ms 200 million cycles VQZ2000 12 ms VQZ3000 15 ms Built-in One-touch fittings for easier piping. Dispersion accuracy 2 ms Metal seal, single solenoid with light/surge voltage suppressor, according to SMC life test conditions. Integral One-touch fittings save on installation time and labor and can be easily removed if necessary.
Auto Switch Specifications Grommet With built-in OFF-delay timer (200 ms) PLC: Abbreviation of Programmable Logic Controller D-F7NTL (With indicator light) CUJ D-F7NTL Auto switch model Wiring type 3-wire CU Output type NPN Output operation Off-delay CQS Operating time 1 ms or less Off-delay time 200 50 ms CQM Applicable load IC circuit, Relay, PLC CQ2 Power supply voltage 5, 12, 24 VDC
Brown ON 80 mA Max. 24 VDC VS VL OFF White Release output Black ON Timer period Blue 20 to 2,000 ms Note) When power is supplied, release output is performed once for the time period only.
Wireless System RoHS Usable even in welding environments High-speed connection Noise resistance Communication response Signal response time: 5 ms Uses the 2.4 GHz ISM frequency band Frequency hopping: Every 5 ms From power supply ON to start of communication: Min. 250 ms*1 *1 For wireless slave Communication cables not required Compatible protocol Number of I/O points Reduced wiring work,
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Input Specification: Current Input, Unit Specification: P [w/Unit Selection Function, Not Allowed for Use in Japan (Initial Value psi)], Lead Wire: Right Angle Lead Wire
Input Specification: Voltage Input, Unit Specification: P [w/Unit Selection Function, Not Allowed for Use in Japan (Initial Value psi)], Lead Wire: None
Input Specification: Voltage Input, Unit Specification: SI Unit Only, Fixed Unit: Pa, kPa, MPa, Lead Wire: Right Angle Lead Wire
Input Specification: Voltage Input, Unit Specification: SI Unit Only, Fixed Unit: Pa, kPa, MPa, Lead Wire: None
Input Specification: Current Input, Unit Specification: SI Unit Only, Fixed Unit: Pa, kPa, MPa, Lead Wire: Right Angle Lead Wire
Input Specification: Current Input, Unit Specification: SI Unit Only, Fixed Unit: Pa, kPa, MPa, Lead Wire: None
Pressure Range: 0 to 1 MPa, Piping: G 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket B, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: None
Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: G 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -