Before piping and screwing in couplings, please make sure that sludge trom pipe threading and sealing materials do not go into the pipe. When seal tape is used, tape winding should be done so that 2 threads are left untaDed on the end.

Please make sure that operating conditions do not cause problems since the use of FEP tubing under chemical environment is unsecured.

Orifice size Electrical entry Orifice diameter 2mm 3mm 4mm 5mm 7mm Class 4 Class 3 Class 2 Symbol 2 3 4 5 7 Voltage G C T TL D DL DO Grommet Conduit Conduit terminal Conduit terminal with light DIN connector DIN connector with light 1 2 3 4 5 6 100VAC 200VAC 110VAC 220VAC 24VDC 12VDC For DIN connector (without connector) All are equipped with surge voltage suppressor.

D -DIN connector DL -DIN connector with light DO-For DIN connector (without connector) Orifice and port size combinations T -With conduit terminal TL-With conduit terminal/light Class Orifice diameter Port size 2 3 4 5 7 10 1/8 (6A) 2 1/4 (8A) 1/4 (8A) 3 3/8 (10A) 1/2 (15A) Connector 1/4 (8A) 3/8 (10A) 4 All class B coils are equipped with surge voltage suppressor.

Specifications Air, Nitrogen Fluid 100 to 0kPa (-14.5 to 0psi) Operating pressure 0.5MPa (72.5psi) Withstand pressure 0 to 60C (32 to 140F) (with no freezing) Operating and ambient temperature range 10m Filtration degree Element differential pressure resistance 0.15MPa (21.75psi) Applicable tubing material Nylon, Soft nylon, Polyurethane, Soft polyurethane Symbol Note) Do not use in a line

Wiring Power supply and N/A communication connector Power LED Communication LED Fig.1 Display and Communication * Please don't do the insert and remove of live-wire after the power supply is turned on. It causes the communication abnormality with the master by the situation.

BRAZIL SMC Pneumaticos do Brazil Ltda. CHILE SMC Pneumatics (Chile) S.A. PERU SMC Corporation Peru S.A.C. VENEZUELA SMC Neumatica Venezuela S.A. OCEANIA AUSTRALIA SMC Pneumatics (Australia) Pty. Ltd. NEW ZEALAND SMC Pneumatics (N.Z.) Ltd. EUROPE AUSTRIA SMC Pneumatik GmbH (Austria) BELGIUM SMC Pneumatics N.V./S.A.

Do not replace the non-rotating guide. Since the non-rotating guide is press fitted, the entire cover assembly needs be replaced instead of a single part. 37

Do not replace the non-rotating guide. Since the non-rotating guide is press fitted, the entire cover assembly needs be replaced instead of a single part. 38

Do not replace the bushings. The bushings are press-fit. To replace them, they must be replaced together with the cover assembly. 2. To replace a seal, apply grease to the new seal before installing it. If the cylinder is put into operation without applying grease to the seal, it could cause the seal to wear significantly, leading to premature air leakage. 3.

Do not service or attempt to remove product and machinery/ equipment until safety is confirmed. 1. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed. 2.

Do not reuse if disassembled. High strength adhesive is applied to the portion of the connection that is threaded to prevent it from loosening, and it must not be disassembled. If it is forcefully disassembled, it could lead to damage. J J 2.The dust cover may stick to the stud.

Do not use an application to operate several cylinders simultaneously by adjusting cylinder speed. If this is inevitable, use a high rigid guide against load, so that the cylinder is not damaged even when the each cylinder output is slightly different. 4.

Do not cut the tube with cutting pliers, nippers, scissors, etc.) 2. Grasp the tube, then slowly push it until it comes to a stop. 3. Then, pull it back gently to make sure that it does not come out.

Note 5) Do not use the V-band type for gases. FGES/FGEL type (V-band type) FGET type (Bolt tightening type) Suitable for medium flow rate, low pressure filtration. Element replacement is easy with the V-band type.

Case Note 1) Cast iron Main material O-ring Material Nominal filtration NBR or FKM Note 2) Paper 5, 10, 20 m 0.6 MPa 0.275 MPa 0.35 MPa Element Differential pressure resistance Differential pressure indicator operating pressure (Element replacement differential pressure) Relief valve open pressure Note 1) There may be scratches, discoloration, slight paint peeling, or other defects which do

When washing the micromesh element, do not wipe it using a stiff brush or rag. 0.03 12 08 20 24 10 16 Pressure drop (MPa) 06 0.01 0.005 COM. N.O.

When installing and removing an element, do not scratch or damage it by touching the corners of the case, etc.

Do not allow the weight of piping to lie directly on air dryer. 4. Do not connect a tube smaller than the port size to the inlet side. In particular, when using a resin tube, make sure that the size would not be smaller than the port size.

With a surge absorption (surge absorption diode) mechanism B A 1021-VQ1000 1021-VQ2000 Caution Do not apply excessive torque when turning the locking type manual override. (0.1 Nm or less) 575 Series VQ1000/2000 Specific Product Precautions 2 1021Be sure to read this before handling.