SMC Corporation of America
Elite Part Number Search
Search Results "11-MXJ4-5"

H13 0.5 0.5 32 22 10 14 15 30 5 32.5 10.5 6.6 45 10.5 5.5 40 38 12 25 12 16 18 35 5 6.6 55 11 5.5 50 46.5 15 27 16 21 20 40 5 51 9 65 15 6.5 63 56.5 15 32 16 21 23 45 5 9 75 15 6.5 80 72 18 36 20 25 27 45 5 11 95 18 10 100 89 18 41 20 25 30 55 11 115 18 10 5 6-13-11 11 Series CP95 Dimensions: Cylinder Mounting Accessory DS and ES [First angle projection] Mounting style (DS) Courtesy

How to Order 10 5. Options 11 6. Structural Drawing and Replacement Parts 12-13 7. Bowl Assembly Specifications 14-21 8. Assembly of Optional Parts 22 9. Operation and Adjustment 23-25 10. Trouble Shooting 26-27 11. How to Replace the Components 28-37 11-1. Diaphragm Assembly Replacement 28 11-2. Bowl Assembly Replacement 29-30 11-3. Element Replacement 31-32 11-4.

mm) 20 25 32 40 W J K KA MM NA PG PH PL S TA TB TC WA WB WH WW XA XB P 30 M5 x 0.8 M4 x 0.7 depth 7 5 6 M8 x 1.25 24 M5 x 0.8 21.5 2 65 141 (149) 11 11 88 15 (16) 23 5.5 3 12 30 M6 x 0.75 M5 x 0.8 depth 7.5 5.5 8 M10 x 1.25 29 M5 x 0.8 26.5 2.5 73 151 (159) 11 11 98 15 (16) 25 6 3 12 25 M8 x 1.0 M5 x 0.8 depth 8 5.5 10 M10 x 1.25 35.5 Rc 1/8 26.5 2.5 73 154 (162) 11 10 (11) 99 15 (16) 28.5

A73H A80H E76A E73A E80A 3-wire (NPN equivalent) A72 A73 A80 A73C A80C 5 V 12 V 200 V 100 V IC circuit 10 16 20 25 32 16 20 25 32 Grommet CXS Relay, PLC 5 V, 12 V 12 V 100 V or less IC circuit 2-wire 24 V Connector 5 V, 12 V 5 V 12 V 24 V or less 100 V IC circuit 10 3-wire (NPN equivalent) DGrommet Relay, PLC 24 V 2-wire 5 V, 12 V 100 V or less IC circuit -X Solid state auto switches

A73H A80H E76A E73A E80A 3-wire (NPN equivalent) A72 A73 A80 A73C A80C 5 V 12 V 200 V 100 V IC circuit 10 16 20 25 32 16 20 25 32 Grommet CXS Relay, PLC 5 V, 12 V 12 V 100 V or less IC circuit 2-wire 24 V Connector 5 V, 12 V 5 V 12 V 24 V or less 100 V IC circuit 10 3-wire (NPN equivalent) DGrommet Relay, PLC 24 V 2-wire 5 V, 12 V 100 V or less IC circuit -X Solid state auto switches

Formulas: L1 = 41n + 76, L2 = 41n + 96 10 486 506 L1 L2 9 445 465 8 404 424 7 363 383 6 322 342 5 281 301 4 240 260 3 199 219 2 158 178 1 117 137 11 527 547 n: Stations (11 stations max.)

Nil W 2-5-5 Base Mounted Series VQ4000 Plug-in Type Conduit terminal 2 position single: VQ410 0 1 23.5 23.5 50 158 50 90 108 158 Indicator light 11(12.5) 11(12.5) 5 3 2(B) port 4(A) port 9 4 2 38 48 10.5 1 11 A B 38 24.6 48 4 2 A 13.5 13.5 30 45 2-5.6 Mounting hole 14 5 1 3 12 30 45 2-5.6 Mounting hole 5-Rc 1/4, 3/8 (5(R1), 3(R2) port Rc 1/4) Manual override Bottom ported drawing 27 4(A),

(With stroke adjuster at retraction end) 6 6-M5 X 0.8 thread 8 deep 2 (With stroke adjuster at extension end) 30 30 76 46 58 FF 22.5 F 25 5H9 5 deep +0.030 0 N -1 x F 2 5H9 5 deep +0.030 0 27 2-M6 X 1 thread 13 deep 13 M 0.5 45.5 50 Z ZZ (NN-1) X H G H 29 11.5 29 11.5 A B 9.5 5.1 11 11 30 1.5 A B 5H9 5 deep +0.030 0 6 NN-M6 X 1 thread 12 deep 5H9 5 deep +0.030 0 HA GA Cross section AA Cross

How to Order 10 5. Options 11 6. Structural Drawing and Replacement Parts 12-13 7. Bowl Assembly Specifications 14-21 8. Assembly of Optional Parts 22 9. Operation and Adjustment 23-25 10. Trouble Shooting 26-27 11. How to Replace the Components 28-37 11-1. Diaphragm Assembly Replacement 28 11-2. Bowl Assembly Replacement 29-30 11-3. Element Replacement 31-32 11-4.

driving force Fn (N) 50 100 100 40 30 CE1 20 30 40 50 20 30 40 50 20 CE2 10 Usable range 10 ML2B 10 Usable range Usable range 5 5 5 C J G5-S CV 1 1 0 2 3 4 5 6 1 1 0 2 3 4 5 6 1 7 8 9 10 11 12 13 7 8 9 10 11 1 0 2 3 4 5 6 7 8 9 101112131415 MVGQ Distance from cylinder shaft center Lo (cm) Distance from cylinder shaft center Lo (cm) Distance from cylinder shaft center Lo (cm) CC

Fn (N) Allowable driving force Fn (N) 50 100 100 40 30 CE1 20 30 40 50 20 30 40 50 20 CE2 10 Usable range 10 ML2B 10 Usable range Usable range 5 5 5 C J G5-S CV 1 1 0 2 3 4 5 6 1 1 0 2 3 4 5 6 1 7 8 9 10 11 12 13 7 8 9 10 11 1 0 2 3 4 5 6 7 8 9 101112131415 MVGQ Distance from cylinder shaft center Lo (cm) Distance from cylinder shaft center Lo (cm) Distance from cylinder shaft center Lo

Product Outline 5 2.1 Product features 6 2.2 Product configuration 7 2.3 How to Order 8 2.4 Option 9 (1) Actuator cable [5 m or less] 9 (2) Actuator cable [8 to 20 m] 9 (3) Actuator cable for actuator with lock (for sensor and lock) [5 m or less] 10 (4) Actuator cable for actuator with lock (for sensor and lock) [8 to 20 m] 11 (5) I/O Cable 11 (6) Communication cable for controller setting

Display and setting of various functions . 5-1 5.1 List of function . 5-1 5.2 Function. 5-2 5.2.1 Key operations . 5-2 5.2.2 List of parameters . 5-4 5.3 Main Display . 5-7 5.3.1 Main Display . 5-7 5.3.2 Items on the main display . 5-7 5.4 Alarm Menu . 5-8 5.4.1 Alarm menu . 5-8 5.4.2 Items shown on the alarm menu display . 5-8 5.5 Check monitor menu . 5-9 5.5.1 Check monitor menu . 5-9 5.5.2

4@3 #5 t @7 $5!5@4 !8@0!7 !9i @2 q r y#0 $0 $2 w $3 #8 @9 A C B Section A !2 !2 #4 @6 #9 @8 $4 #2 #1 #6 #7 $6 !0 u @5 !6 @1 !1 $7 o $8 e $1 !2 Section B Section C 100 80 63 50 40 32 80, 100 80, 100 Description Material Note Parts list Description Material Note Parts list No. No.

Set the mounting band perpendicularly to cylinder tube. 20 50 63 80 100 25 32 40 D-B7/B80 8 10 9 10 10 11 D-B73C/B80C D-C7/C80 8 10 9 10 10 11 D-C73C/C80C 8 10 9 10 10 11 D-B5/B64 11 11 MX Mounting correctly Mounting incorrectly 13 13 14 14 14 17 D-B59W 18 16 D-G79/K79 8 10 9 10 10 11 Auto Switch Mounting Bracket Part No.

Display and setting of various functions . 5-1 5.1 List of function . 5-1 5.2 Function. 5-2 5.2.1 Key operations . 5-2 5.2.2 List of parameters . 5-4 5.3 Main screen . 5-7 5.3.1 Main screen . 5-7 5.3.2 Display on the main screen . 5-7 5.4 Alarm display menu . 5-8 5.4.1 Alarm display menu . 5-8 5.4.2 Content of display of alarm display menu . 5-8 5.5 Inspection monitor menu . 5-9 5.5.1 Inspection

Note 1) D1: Max. diameter Note 2) ( ): Values for nylon. 15-3-11 5 Series KG Male Branch Connector: KGLU H (width across flats) Connection thread R Model Effective area (mm2) Nylon Urethane Applicable tubing O.D.

7 11 4 22 40 38.4 29 4 70.5 56 40 188 170 CG-E032SUS 50 14 189 12 15 5 25 50 59.6 35 6 106.5 84 50 224 204 CG-E050SUS 63 14 189 12 15 5 25 50 59.6 35 6 106.5 84 50 224 204 CG-E050SUS 80 22 234 14 23 6 40 80 87.2 57 9 144.5 120 80 291 257 CG-E080SUS 100 22 235 14 23 6 40 80 87.2 57 9 144.5 120 80 292 258 CG-E080SUS Plug bolts are installed before shipment from factory.

-10 to 10 V -5 to 5 V -20 to 20 mA F 65535 10.5 5.25 21 F9E8 63976 10 5 20 BCF4 48372 5 2.5 10 8000 32768 0 0 0 430C 17164 -5 -2.5 -10 0618 1560 -10 -5 -20 0 0 -10.5 -5.25 -21 Data format Byte0 Byte1 CH0 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 MSB AD value LSB Byte2 Byte3 CH1 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 MSB AD value LSB -21No.EX-OMN0038-C (2)Signed binary data format and twos complement