Common (+, ) Station 1 A side Station 1 B side Station 2 A side Station 2 B side Station 3 A side Substrate for single Station 3 Substrate for double Station 2 Substrate for double Station 1 A and B ports can be individually controlled. Three combinations are available: [N.C./N.C.], [N.O./N.O.] and [N.C./N.O.].
Model A side B side JIS Symbol A relay output module of devices up to 110 A B is available for control VAC, 3 A. 4(A) 2(B) A B N.C. valve N.C. valve 3(EB) SOL.b SOL.a 1 2 SV A00 5(EA) B side passage symbol: Green B side manual override: Green Tie-rod base manifold (For SV1000/2000/3000/4000) 1(P) 4(A) 2(B) A side coil A side spool valve B side spool valve N.O. valve N.O. valve 1 2 SV B00
7 PFM (12) 2 (11) 10 0.210(5)L/min 1 25 0.525(12.5)L/min (11) 50 150(25)L/min 11 2100(50)L/min 1( )CO2 A 2 2 S () N 3 M SI4 3 (SI) 4L/min,L A NPN(2) B PNP(2) C NPN(1)+(15V) D NPN(1)+(420mA) E PNP(1)+(15V) F PNP(1)+(420mA) G NPN(1)+5 H PNP(1)+5 5 L 6INOUT () 10 25 50 11 01 Rc1/8 02 Rc1/4 N01 NPT1/8 N02 NPT1/4 F01 G1/8 F02 G1/4 C4 4(5/32") C6 6 C8 8(5/16") N7 1/4 -10No.PF-OMJ0005CN-I
Caution Refer to p.0-33 to 0-36 for Safety Instruction and common precautions. 3.2-13 VFA3000 Dimensions/Body Ported 2 position single: VFA3122-F 01 02 SlA VlA SlA VlA VM/VR VH 2 position single: VFA3130-01 02 3.2-14 VFA3000 Dimensions/Body Ported 2 position double: VFA3230-01 02 3 position closed center/exhaust center/pressure center: VFA3 30-X1 01 02 3 4 5 3.2-15 VFA3000 Dimensions/Base
PSE56-C01 24 B PSE56-A2 A B Model 8.2 12 9.2 12.2 15.5 9.5 A PSE56-01 PSE56-02 PSE56-N01 PSE56-N02 PSE56-C01 PSE56-A2 PSE56-B2 R 1/8 R 1/4 NPT 1/8 NPT 1/4 Rc 1/8 URJ 1/4 TSJ 1/4 24 B PSE56-B2 A 24 B 16-3-28 7 Series PSE Specific Product Precautions 1 Be sure to read before handling. Pressure Sensor Handling Air Supply Warning Warning ZSE ISE 1.
1 1 2 F P Q 01 06 Lock nut option Nil J Body size Hexagon lock nut Round lock nut 1 2 3 4 M5 standard 1/8, 1/4 standard 3/8 standard 1/2 standard Applicable tubing O.D.
1 1 2 F P Q 01 06 Lock nut option Nil J Body size Hexagon lock nut Round lock nut 1 2 3 4 M5 standard 1/8, 1/4 standard 3/8 standard 1/2 standard Applicable tubing O.D.
RY(n 2)E RY(n 2)D RY(n 2)C 0 0 0 1 0 0 1 2 0 1 0 3 0 1 1 4 1 0 0 5 1 0 1 6 1 1 0 7 1 1 1 8 Note. 0: OFF 1: ON RY(n 1)A RY(n 3)A Reset Keeping RY(n 1)A or RY(n 3)A ON for 50ms or longer allows an alarm to be deactivated. Some alarms cannot be deactivated by Reset RY(n 1)A or RY(n 3)A.
RY(n 2)E RY(n 2)D RY(n 2)C 0 0 0 1 0 0 1 2 0 1 0 3 0 1 1 4 1 0 0 5 1 0 1 6 1 1 0 7 1 1 1 8 Note. 0: OFF 1: ON RY(n 1)A RY(n 3)A Reset Keeping RY(n 1)A or RY(n 3)A ON for 50ms or longer allows an alarm to be deactivated. Some alarms cannot be deactivated by Reset RY(n 1)A or RY(n 3)A.
A b . A b . A PLCetc Axis Axis Axis No. 1 No. 2 No. 3 "b01" is displayed on axis No. 1, "Ab." is displayed on axis No. 2 and later. PC or PLCetc Controller After PC or PLCetc reset 0 1 b b . A b . A One axis is connected per reset.
1) (Note 1) A.52 Error excessive A.8E USB communication error 888 Watchdog 8 2 8.
A B A B A B B A B A B A B B A B A B A 10 16 2 2 6 6 2.5 2.5 1.5 1.5 0.5 0.5 4.5 4.5 3 3 3.5 3.5 8.5 8.5 0.5 0.5 2.5 2.5 6.5 6.5 3 3 2 2 1 1 5 5 3.5 3.5 4 4 9 9 1 1 Note) Adjust the auto switch after confirming the operating conditions in the actual setting.
Body size Metric size Inch size 3 4 5 6 1/8 1/4 3/8 1/2 07 09 11 13 06 08 10 12 6mm 8mm 10mm 12mm 1/4 5/16 3/8 1/2 Thread size Universal type 01 02 03 04 1/8 1/4 3/8 1/2 With One-touch fitting Uni-fit thread form Dimensions Models TUBE O.D. d L3 Applicable tubing O.D.
E1 1] () () Ready on ON 0.8 s 0.8s 0.8 s 0.8s OFF 3 3 LED LED ON ON . 2 . 1 2 64 1 2 64 4 11 4. (2) (SW2-3SW2-4)(SW1) "Ab""AC""Ad""Ab" A b A b . A C A d A E A F A H A A (1) b # # Ready-off Ready-off (1) d # # ON ON (1) C # # OFF OFF (2) * * * (8) 8 8 8 CPU CPU (1) # # b . (3) # # d . # # C . 1. ## ## 01 1 64 64 2. *** 3.
Body size 10 20 Max. flow 140 l/min (ANR) Max. flow 240 l/min (ANR) Symbol X1 Specification Integrated digital pressure switch for panel mounting Accessory w Single sided connections None Note 1) Nil With pressure gauge Note 2) Note 3) (IRV10A: With GZ33-K-01, IRV20A: With GZ43-K-01) A Single sided connections G Note 3) ZN ZP ZA ZB With ZSE30A-01-N-ML With ZSE30A-01-P-ML With ZSE30A-01-A-ML
A C A d A E A F A H A A (1) b # # Ready-off Ready-off (1) d # # ON ON (1) C # # OFF OFF (2) * * No.No.81 8 8 8 CPU CPU (3) 0 0. b JOGDO (1) # #. b (3) # #. d # #. C 1. ##0016 ## 00 01 1 02 2 03 3 04 4 05 5 06 6 07 7 08 8 09 9 10 10 11 11 12 12 13 13 14 14 15 15 16 16 2. **No. 3.
(Looked by double solenoid valve) (Looked by double solenoid valve) SOL. location B (*) B (*) B B A B A B A B A B A A A A B A B A SOL. location VQC 3 position 3 position Double Double Double Double SI unit Single Single SI unit Single Single SQ Stations 1 2 3 4 5 Stations 1 2 3 4 5 VQ0 The places of asterisk are not used.
When the product is mounted so that the exhaust port side will be against a wall, use a spacer to secure a clearance of at least 0.039 inch (1 mm). (Fig. 1) For the single unit, PV port and PD port are oriented downward. When it is installed on a working table, use a bracket for single unit (Fig. 2) or secure a space for piping underneath the ports.
07 09 1 1 1 3 06 08 1 0 1 2 1 6 ;il H,r ,u x,N 1 2 m m Double universal male elbow 10 32 UNF Thread 1/16" NPT 1/8' NPT l+ trtpr H L' w' T' Y U' E Hex. socket head universalelbow 33 34 Extended Different dia. branch "Y" Double branch "Y" M5 M6 01 02 03 04 M5 x 0.8 N46 x 1.0 PT1/8 PI1/4 PT3/8 Pr1/2 a a a a a a a a a a a a a a a a a a a a a a r ) a a a a a a a a The use of compact spacer with
Circuit (Class 2) of maximum 30 Vrms (42.4 V peak) or less, with UL1310 Class 2 power supply unit or UL1585 Class 2 transformer. The product is a UL approved product only if it has a mark on the body. Use the specified voltage. Otherwise failure or malfunction can result. Insufficient supply voltage may not drive a load due to a voltage drop inside the product.