SMC Corporation of America
Elite Part Number Search
Search Results "CDLG1FA32-125-E"

For sub-plate, manifold type 40, 41, 42 P, E port R port Port size 3:Common exhaust type for main and pilot valve Nil: Without sub-plate D: Push-turn locking slotted type P, E port R port Electrical entry (With gasket and screws) 24, 12, 6, 5, 3 VDC 100,110, 200, 220 VAC Grommet L plug connector M plug connector 24,12 VDC 100,110, 200, 220 VAC DIN terminal 24, 12, 6, 5, 3 VDC M8 connector

F Pin hole a side a side Mounting tap: M12 x 1.75 Pin diameter: 10H7 Port Body (mounting side) C Port a side ( side) b side ( side) b side Clamp arm positioin (clockwise from top) Port a side : Mounting tap : Pin diameter : Mounting tap : Pin diameter D 180 from port Same direction as port b side Guide pin Port E 66 Port b side A C E Clamp arm Guide pin Clamp arm Port a side Mounting hole

M o u n V F l a n g e M o u n t . . . . . . . . . 7 4 Construction/Parts List . . .

A contact protection box is not required for solid state auto switches due to their construction. q Where the operation load is an inductive load. w Where the wiring length to load is greater than 5 m. e Where the load voltage is 100 VAC.

E EtherCAT 9 EtherNet/IP P PROFINET D DeviceNet L IO-Link Mounting 7 Screw mounting 8*1 DIN rail *1 The DIN rail is not included. It must be ordered separately. (Refer to page 7.) * Only the step motor type is applicable.

E E KF K Fd Fn C D H B A G A mm A B C D E Fn Fd G H XLA-16-2 40 108 38 20 30 17 44 XLA-25-2 50 121 48 27 12 40 26 44 XLA-40-2 65 171 66 39 11 55 41 67 XLA-50-2 70 185 79 46 11 75 52 72 XLA-63-2 88 212 100 55 11 87 95 70 76 XLA-80-2 90 257 117 65 11 114 110 83 104 12 XL-OMY0001 6. 200 []1 1.5 1 200 FKM 110Pa <> 13 XL-OMY0001 7 7-1. 2 2P5P6 14 XL-OMY0001 7-2 1 2 1 3 1 1 2 4 1 0.4MPa

LJ1 60 72 A A Motor mounting area B Section BB When mounting a coupling on the motor, mount it within the dimensional range shown on the left. 9.2 Thread P.C.D. 32.5 Coupling Motor 29.5 30 8 Dimensions D C F D E With brake (mm) 101 8.5 26 32 Without brake (mm) 93 17 19 27.5 E F Coupling mounting dimensions Section AA (Housing interior) Series LJ1H S20 Motor mounting area dimensions Mitsubishi

: inch (mm) 10mm N 3/8 B Q E D A G C F 1 J 31.5 [820] P L K M N H (L=2800) IDFB4E/6E/8E/11E-11 1. : inch (mm) 10mm N 3/8 A B E D Q G C F 1 J 31.5[800] H N M 4-0.5 (L=2800) [4-13] 6-3 6 3 IDFB Series IDX-OM-W020 6 IDFB15E-11 1. : inch (mm) 10mm N 3/8 E D B A Q G C F (820) K L P N M H J 4-13 (L=2800) (inch [mm]) A B C D E F G H J K L M N P Q IDFB3E 3/8 8.9 16.1 18.6

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No, Operating

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 110, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No, Operating

Magnet: D (Built-in), Mounting: F (Front Flange), Style: A (Non-lube Air Cushion), Bore Size: 32mm, Thread: None, Stroke: 150mm, Option: None, Lock Style: P (Air Pressure Lock-up (Pressure Lock))

Magnet: D (Built-in), Mounting: F (Front Flange), Style: A (Non-lube Air Cushion), Bore Size: 32mm, Thread: None, Stroke: 150mm, Option: None, Lock Style: D (Spring/Air Pressure Lock)

Magnet: D (Built-in), Mounting: F (Front Flange), Style: A (Non-lube Air Cushion), Bore Size: 32mm, Thread: None, Stroke: 100mm, Option: None, Lock Style: D (Spring/Air Pressure Lock)

Magnet: D (Built-in), Mounting: F (Front Flange), Style: A (Non-lube Air Cushion), Bore Size: 32mm, Thread: None, Stroke: 50mm, Option: None, Lock Style: D (Spring/Air Pressure Lock)

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No, Operating

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 110, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No, Operating

Magnet: Built-in, Mounting: Front Flange, Style: Non-lube Air Cushion, Bore Size: 32mm, Thread: None, Stroke: 150mm, Option: None, Lock Style: Air Pressure Lock-up (Pressure Lock), Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -

Magnet: Built-in, Mounting: Front Flange, Style: Non-lube Air Cushion, Bore Size: 32mm, Thread: None, Stroke: 150mm, Option: None, Lock Style: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -

Magnet: Built-in, Mounting: Front Flange, Style: Non-lube Air Cushion, Bore Size: 32mm, Thread: None, Stroke: 100mm, Option: None, Lock Style: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -