Magnet: None, Mounting: G (Rear Flange), Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 500mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: P (Air Pressure Lock-up)
Magnet: None, Mounting: G (Rear Flange), Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 200mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock)
Magnet: None, Mounting: G (Rear Flange), Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 25mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock)
Magnet: None, Mounting: G (Rear Flange), Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 50mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock)
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Magnet: None, Mounting: Rear Flange, Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 300mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Magnet: None, Mounting: Rear Flange, Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 100mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Air Pressure Lock-up, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Magnet: None, Mounting: Rear Flange, Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 150mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Air Pressure Lock-up, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Magnet: None, Mounting: Rear Flange, Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 25mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Air Pressure Lock-up, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Magnet: None, Mounting: Rear Flange, Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 500mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Magnet: None, Mounting: Rear Flange, Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 500mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Air Pressure Lock-up, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Magnet: None, Mounting: Rear Flange, Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 200mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Magnet: None, Mounting: Rear Flange, Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 25mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Differential pressure indication switch r O-ring Applicable Applicable q O-ring w O-ring e O-ring Port size order no. hydraulic hydraulic order no. order no. order no.
(Station 5) Type of actuation Light/Surge voltage suppressor 1 2 3 4 5 6 2 position single 2 position double 3 position closed center 3 position exhaust center 3 position pressure center 3 position double check Nil E Yes Without light, with surge voltage suppressor Prefix the asterisk to the part nos. of the solenoid valve, etc.
K Screw for bracket Panel mounting bracket (Standard) Type E snap ring M Plate Operation on the panel front permits mounting. Holes for mounting bolts are not necessary. (Mountable panel thickness is 5 mm maximum.)
For sub-plate, manifold type 40, 41, 42 P, E port R port Port size 3:Common exhaust type for main and pilot valve Nil: Without sub-plate D: Push-turn locking slotted type P, E port R port Electrical entry (With gasket and screws) 24, 12, 6, 5, 3 VDC 100,110, 200, 220 VAC Grommet L plug connector M plug connector 24,12 VDC 100,110, 200, 220 VAC DIN terminal 24, 12, 6, 5, 3 VDC M8 connector
F Pin hole a side a side Mounting tap: M12 x 1.75 Pin diameter: 10H7 Port Body (mounting side) C Port a side ( side) b side ( side) b side Clamp arm positioin (clockwise from top) Port a side : Mounting tap : Pin diameter : Mounting tap : Pin diameter D 180 from port Same direction as port b side Guide pin Port E 66 Port b side A C E Clamp arm Guide pin Clamp arm Port a side Mounting hole
M o u n V F l a n g e M o u n t . . . . . . . . . 7 4 Construction/Parts List . . .